Automated localization and quality control of the aorta in cine CMR can significantly accelerate processing of the UK Biobank population data. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Aortic distensibility can be calculated using semi-automated methods to segment the aortic lumen on cine CMR (Cardiovascular Magnetic Resonance) images. However, these methods require visual quality control and manual localization of the region of interest (ROI) of ascending (AA) and proximal descending (PDA) aorta, which limit the analysis in large-scale population-based studies. Using 5100 scans from UK Biobank, this study sought to develop and validate a fully automated method to 1) detect and locate the ROIs of AA and PDA, and 2) provide a quality control mechanism.

Methods: The automated AA and PDA detection-localization algorithm followed these steps: 1) foreground segmentation; 2) detection of candidate ROIs by Circular Hough Transform (CHT); 3) spatial, histogram and shape feature extraction for candidate ROIs; 4) AA and PDA detection using Random Forest (RF); 5) quality control based on RF detection probability. To provide the ground truth, overall image quality (IQ = 0-3 from poor to good) and aortic locations were visually assessed by 13 observers. The automated algorithm was trained on 1200 scans and Dice Similarity Coefficient (DSC) was used to calculate the agreement between ground truth and automatically detected ROIs.

Results: The automated algorithm was tested on 3900 scans. Detection accuracy was 99.4% for AA and 99.8% for PDA. Aorta localization showed excellent agreement with the ground truth, with DSC ≥ 0.9 in 94.8% of AA (DSC = 0.97 ± 0.04) and 99.5% of PDA cases (DSC = 0.98 ± 0.03). AA×PDA detection probabilities could discriminate scans with IQ ≥ 1 from those severely corrupted by artefacts (AUC = 90.6%). If scans with detection probability < 0.75 were excluded (350 scans), the algorithm was able to correctly detect and localize AA and PDA in all the remaining 3550 scans (100% accuracy).

Conclusion: The proposed method for automated AA and PDA localization was extremely accurate and the automatically derived detection probabilities provided a robust mechanism to detect low quality scans for further human review. Applying the proposed localization and quality control techniques promises at least a ten-fold reduction in human involvement without sacrificing any accuracy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6375606PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0212272PLOS

Publication Analysis

Top Keywords

quality control
20
ground truth
12
localization quality
8
cine cmr
8
pda
8
pda aorta
8
scans
8
rois pda
8
automated pda
8
candidate rois
8

Similar Publications

Primary agricultural products are closely related to our daily lives, as they serve not only as raw materials for food processing but also as products directly purchased by consumers. These products face the issue of freshness decline and spoilage during both production and consumption. Freshness degradation induces sensory deterioration and nutritional loss and promotes harmful substance accumulation, causing gastrointestinal issues or even endangering life.

View Article and Find Full Text PDF

A major cause of cancer death, colorectal cancer is becoming more common in younger people. The comparative effectiveness of robotic versus laparoscopic total mesorectal excision (TME) as surgical interventions for mid-low rectal cancer following neoadjuvant chemoradiotherapy (nCRT) remains uncertain. To systematically evaluate oncological, perioperative, and survival outcomes of robotic versus laparoscopic surgery for mid-low rectal cancer following nCRT.

View Article and Find Full Text PDF

Purpose: To compare the effects of cervical stabilization exercise training via telerehabilitation (CSET-T) in addition to standard treatment on pain, forward head posture, cervical mobility, muscle performance, functional status, sleep quality, and quality of life in individuals with migraine in comparison to the standard treatment alone.

Methods: The control group (n = 20) received standard treatment alone (medication+recommendations). The stabilization group (n = 20) was given CSET-T in addition to standard treatment 3 days a week for 8 weeks.

View Article and Find Full Text PDF

Quality control of drug products is an essential step in pharmaceutical manufacturing. It is often time-consuming and requires expensive equipment. Process analytical technology tools are typically integrated into the manufacturing process to monitor quality, thereby reducing time and costs.

View Article and Find Full Text PDF

Staff perceptions of their roles in infection prevention and control in residential aged care homes: A qualitative study.

Am J Infect Control

September 2025

School of Nursing and Midwifery and Centre for Quality and Patient Safety Research in the Institute for Health Transformation, Deakin University, Geelong, Victoria, Australia; Centre for Quality and Patient Safety Research - Eastern Health Partnership, Eastern Health, Box Hill, Victoria, Australia.

Background: Older people who live in residential aged care homes (RACHs) are particularly vulnerable to infections. Without staff commitment and engagement, even the most well-designed policies and guidelines may fail to achieve infection prevention and control (IPAC) effectiveness. The aim of this study was to examine staff perceptions of their roles in IPAC in RACHs.

View Article and Find Full Text PDF