Analytical Formulation of the Electric Field Induced by Electrode Arrays: Towards Automated Dielectrophoretic Cell Sorting.

Micromachines (Basel)

FEMTO-ST Institute, AS2M Department, Univ Bourgogne Franche-Comté, CNRS, 24 rue Alain Savary, 25000 Besancon, France.

Published: August 2017


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Dielectrophoresis is defined as the motion of an electrically polarisable particle in a non-uniform electric field. Current dielectrophoretic devices enabling sorting of cells are mostly controlled in open-loop applying a predefined voltage on micro-electrodes. Closed-loop control of these devices would enable to get advanced functionalities and also more robust behavior. Currently, the numerical models of dielectrophoretic force are too complex to be used in real-time closed-loop control. The aim of this paper is to propose a new type of models usable in this framework. We propose an analytical model of the electric field based on Fourier series to compute the dielectrophoretic force produced by parallel electrode arrays. Indeed, this method provides an analytical expression of the electric potential which decouples the geometrical factors (parameter of our system), the voltages applied on electrodes (input of our system), and the position of the cells (output of our system). Considering the Newton laws on each cell, it enables to generate easily a dynamic model of the cell positions (output) function of the voltages on electrodes (input). This dynamic model of our system is required to design the future closed-loop control law. The predicted dielectrophoretic forces are compared to a numerical simulation based on finite element model using COMSOL software. The model presented in this paper enables to compute the dielectrophoretic force applied to a cell by an electrode array in a few tenths of milliseconds. This model could be consequently used in future works for closed-loop control of dielectrophoretic devices.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6189918PMC
http://dx.doi.org/10.3390/mi8080253DOI Listing

Publication Analysis

Top Keywords

closed-loop control
16
electric field
12
dielectrophoretic force
12
electrode arrays
8
dielectrophoretic devices
8
compute dielectrophoretic
8
electrodes input
8
dynamic model
8
dielectrophoretic
7
model
6

Similar Publications

General event-triggered dynamic output feedback control for complex networks subject to cyber attacks.

ISA Trans

September 2025

School of Science, Yanshan University, Qinhuangdao Hebei, 066004, PR China. Electronic address:

This article concentrates on the issue of event-triggered dynamic output feedback control for Markovian jump complex dynamical networks (MJCNDs) subject to multiple cyberattacks. To alleviate the communication pressure, a new adaptive event-triggered mechanism (AETM) is proposed. This AETM incorporates a dynamically adjustable parameter and mode-dependent properties to enhance flexibility.

View Article and Find Full Text PDF

Robust tracking control of uncertain autoloaders by implicit Lyapunov method and scleronomic Lagrangian mechanics-informed neural network.

ISA Trans

September 2025

Key Laboratory of Metallurgical Equipment and Control Technology of Ministry of Education, Wuhan University of Science and Technology, Wuhan, 430081, Hubei, China; Hubei Key Laboratory of Mechanical Transmission and Manufacturing Engineering, Wuhan University of Science and Technology, Wuhan, 430081

The autoloader is a key subsystem in modern main battle tanks, mainly responsible for ammunition transfer, loading, and resupply. However, it often suffers from uncertainties induced by base oscillations, leading to potential instability. While various control strategies have been proposed, most rely on prior knowledge of such oscillations.

View Article and Find Full Text PDF

Organoids have emerged as powerful models for recapitulating tissue physiology and pathology in biomedical research. However, the need for consistent and complex manufacturing of organoids remains a challenge. The absence of standardization and quality control of cells dispersed within extracellular matrices impedes the widespread application of organoids.

View Article and Find Full Text PDF

Objective: To investigate the effect of innovative perioperative pain management on prostate cancer patients with hematuria undergoing prostatic artery embolization (PAE).

Methods: A total of 60 patients undergoing PAE in the Interventional Therapy Department of General Hospital of Eastern Theater Command from May 2024 to January 2025 were selected by convenience sampling method and randomly divided into the intervention group and the control group, with 30 patients in each group. The control group received traditional pain management of nursing.

View Article and Find Full Text PDF

CamAPS FX is a customizable hybrid closed-loop app with a default target glucose of 105 mg/dL. The personal glucose target is user-adjustable in 1 mg/dL increments between 80 and 198 mg/dL in 30-min segments over 24 h. We assessed the impact of different personal glucose targets on glycemic control during real-world use of CamAPS FX in different age-groups.

View Article and Find Full Text PDF