Upper-eyelid weight implants for patients with lagophthalmos-comparison of rigid and flexible implants.

J Craniomaxillofac Surg

Department of Oral, Craniomaxillofacial and Facial Plastic Surgery, (Head: Prof. Dr. Dr. Alexander Hemprich), Faculty of Medicine, University Hospital of Leipzig, Germany. Electronic address:

Published: October 2018


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: For treatment of lagophthalmos, metallic weight implants can be inserted in the upper eyelid to aid eyelid closure. Rigid and flexible implants are available. The objective of this study was to investigate the effect of implant type and patient variables on the survival of lid load implants.

Materials And Methods: Forty-four patients with lagophthalmos were recruited to undergo upper-eyelid weight implantation. The predictor variable was type of implant inserted (rigid or flexible). The outcome variable was survival of the inserted implant (survival or extrusion). Other study variables were demographic data (age, gender), implant features (material, weight), and other conditions, such as history of radiation. An NMLE test was used to compare implant survival, depending on implant type (flexible versus rigid). Other variables were analysed by use of a χ test.

Results: Forty-four participants were recruited, 29 female (65.9%) and 15 male (34.1%). Forty-six implants (23 rigid implants, 50.0%; 23 flexible implants, 50.0%) were inserted (bilateral implantation in two patients). The average weight of implants used was 1.76 g (range 1.4-2.2 g). One to two years after surgery, average vertical aperture (eyelid gap) for the closed eye was 0.65 mm (range 0-4 mm). Incidence of extrusion was 15.2% (one in the rigid implant group, 2.2%; six in the flexible implant group, 13.0%). Incidence of extrusion was significantly higher for flexible implants than for rigid implants (p = 0.0273).

Conclusions: The study results suggest that flexible implants are more likely to perforate the skin. The assumed advantages of the expensive chain lid weight must, therefore, be re-evaluated.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcms.2018.07.015DOI Listing

Publication Analysis

Top Keywords

flexible implants
20
weight implants
12
rigid flexible
12
implants
11
upper-eyelid weight
8
flexible
8
implant
8
implant type
8
implant survival
8
implants rigid
8

Similar Publications

[Biphasic plate-Controlled instability in fracture healing].

Unfallchirurgie (Heidelb)

September 2025

Klinik für Unfall‑, Hand- und Wiederherstellungschirurgie, Universitätsklinikum Münster, Albert-Schweitzer-Campus 1, Gebäude W1, 48149, Münster, Deutschland.

The bony consolidation of fractures depends on various factors. Under optimal conditions fracture healing takes place within a few weeks. An essential requirement for fracture healing is the restoration of adequate biomechanical stability with an interfragmentary movement which is as ideal as possible.

View Article and Find Full Text PDF

Design and Fabrication of Flexible Silk Fibroin/Lanthanide Ion Membranes with Multifunctional Properties of Fluorescence, Humidity Sensitivity, and Conductivity.

ACS Appl Mater Interfaces

September 2025

College of Chemistry and Chemical Engineering, Instrumental Analysis Center of Qingdao University, Qingdao Application Technology Innovation Center of Photoelectric Biosensing for Clinical Diagnosis and Treatment, Shandong Sino-Japanese Center for Collaborative Research of Carbon Nanomaterials, Qing

Silk fibroin (SF)-based flexible electronic/photonic materials have gained great attention in wearable devices and soft sensors. However, it remains challenging to understand the molecular interaction mechanisms and subsequently fabricate SF-based flexible materials that exhibit fluorescence, humidity sensitivity, and conductivity properties. In this study, by incorporating lanthanide europium ion (Eu), the design and fabrication of a flexible, fluorescent, and conductive SF membrane was proposed.

View Article and Find Full Text PDF

α-Cyclodextrin mediated 3D printed ceramic/polymer composite scaffolds for immunomodulation and osteogenesis in bone defect repair.

Biomater Adv

September 2025

Quanzhou Institute of Equipment Manufacturing, Fujian Institute of Research on the Structure of Matter, Chinese Academy of Sciences, Fuzhou, Fujian, 350002, China; Fujian Science and Technology Innovation Laboratory for Optoelectronic Information of China, Fuzhou, Fujian, 350108, China; University o

Bone tissue engineering scaffolds for bone defect treatment face numerous challenges, including mechanical mismatches and the lack of immune microenvironment modulation, often leading to implant failure. In this study, an innovative drug-loaded bioinspired ceramic/polymer composite scaffold was designed and fabricated using extrusion-based 3D printing technology, incorporating α-cyclodextrin (αCD) in a novel approach to improve interfacial compatibility and drug-loading efficiency. Hydroxyapatite (HA), the main component of natural bone, was employed as the inorganic phase to mimic the mineral structure of bone tissue.

View Article and Find Full Text PDF

Brain-computer interfaces (BCIs) enable communication between individuals and computers or other assistive devices by decoding brain activity, thereby reconstructing speech and motor functions for patients with neurological disorders. This study presents a high-resolution micro-electrocorticography (µECoG) BCI based on a flexible, high-density µECoG electrode array, capable of chronically stable and real-time motor decoding. Leveraging micro-nano manufacturing technology, the µECoG BCI achieves a 64-fold increase in electrode density compared to conventional clinical electrode arrays, enhancing spatial resolution while featuring scalability.

View Article and Find Full Text PDF

A novel P-type Buried Layer Diode-Triggered Silicon-Controlled Rectifier (PBL-DTSCR) with predicted good performance in electrostatic discharge (ESD) protection is proposed in this work. With P-type ESD implantations and silicide blocking layers applied to this novel structure, the efficiency of the diode triggering path is greatly improved, thus enhancing the discharge efficiency of the main path. Moreover, the parasitic SCR path is minimized by replacing the PNPN structure in conventional DTSCR to PNPNPN structure in PBL-DTSCR.

View Article and Find Full Text PDF