98%
921
2 minutes
20
This paper investigates the problem of an optimal sensor placement for better shape deformation sensing of a new antenna structure with embedded or attached Fiber Bragg grating (FBG) strain sensors. In this paper, the deformation shape of the antenna structure is reconstructed using a strain⁻displacement transformation, according to the measured discrete strain data from limited FBG strain sensors. Moreover, a two-stage sensor placement method is proposed using a derived relative reconstruction error equation. In this method, the initial sensor locations are determined using the principal component analysis based on orthogonal trigonometric (i.e., QR) decomposition, and then a new location is sequentially added into the initial sensor locations one by one by minimizing the relative reconstruction error considering information redundancy. The numerical simulations are conducted, and the comparisons show that the proposed method is advantageous in terms of the sensor distribution and computational cost. Experimental validation is performed using an antenna experimental platform equipped with an optimal FBG strain sensor configuration, and the reconstruction results show good agreements with those measured directly from displacement sensors. The proposed method has a large potential for the strain sensor placement of complex structures, and the proposed antenna structure with FBG strain sensors can be applied to the future wing-skin antenna or flexible space-based antenna.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6111766 | PMC |
http://dx.doi.org/10.3390/s18082481 | DOI Listing |
Prog Mol Biol Transl Sci
September 2025
Heidelberg Institute of Global Health (HIGH), Faculty of Medicine and University Hospital, Heidelberg University, Heidelberg, Germany. Electronic address:
Climate change poses a growing threat to human health, increasing exposure to extreme environmental conditions. Wearable biosensors provide real-time monitoring of physiological responses to heat stress, including cardiovascular strain, thermoregulatory disruptions, sleep disturbances, and biomarkers of heat-related illnesses. These devices also assess behavioural adaptations, such as reduced physical activity, offering insights into physiological resilience and susceptibility.
View Article and Find Full Text PDFACS Chem Neurosci
September 2025
Chemical and Biomolecular Engineering Dept, University of California, Los Angeles, Los Angeles, California 90095, United States.
Simulations in three dimensions and time provide guidance on implantable, electroenzymatic glutamate sensor design; relative placement in planar sensor arrays; feasibility of sensing synaptic release events; and interpretation of sensor data. Electroenzymatic sensors based on the immobilization of oxidases on microelectrodes have proven valuable for the monitoring of neurotransmitter signaling in deep brain structures; however, the complex extracellular milieu featuring slow diffusive mass transport makes rational sensor design and data interpretation challenging. Simulations show that miniaturization of the disk-shaped device size below a radius of ∼25 μm improves sensitivity, spatial resolution, and the accuracy of glutamate concentration measurements based on calibration factors determined .
View Article and Find Full Text PDFChaos
September 2025
Complex Systems Group & Grupo Interdisciplinar de Sistemas Complejos, Universidad Rey Juan Carlos, 28933 Móstoles, Madrid, Spain.
A flat control law is based on the structural analysis of a controlled system, allowing optimal placement of sensors and actuators. Once designed, any desired dynamics can be imposed onto the system. When the target dynamics comes from a system structurally different from the controlled one, generalized synchronization can be achieved, provided the control gain is sufficiently large.
View Article and Find Full Text PDFAdv Sci (Weinh)
September 2025
Department of Orthodontics, National Center for Stomatology, National Clinical Research Center for Oral Diseases, National Engineering Research Center of Oral Biomaterials and Digital Medical Devices, Beijing Key Laboratory of Digital Stomatology, NHC Key Laboratory of Digital Stomatology, NMPA Key
Clear aligners offer aesthetic and comfort advantages in orthodontics, yet their ability to deliver effective forces relies heavily on empirical judgment or large-scale optical scanning, lacking real-time quantitative evaluation. Integrating pressure sensors into aligners is a promising solution, but challenges in miniaturization, multi-dimensional sensing, measurement accuracy, and biocompatibility hinder clinical application. Here, an all-in-one Orthodontic Force Acquisition System (OFAS) is presented that enables real-time, 3D force monitoring using a cross-shaped iontronic sensing array and an origami-inspired, wireless battery-free readout circuit miniaturized for single-tooth placement.
View Article and Find Full Text PDFBMC Urol
September 2025
Department of Urology, School of Medicine, University of California, 9300 Campus Point Drive, La Jolla, San Diego, CA, 92037, USA.
Background: Decreasing radiation exposure in renal colic management involves revisiting diagnostic, intraoperative, and postoperative practices. One approach is a shift in procedural standards from intraoperative fluoroscopy to ultrasonography. Despite the increased implementation of ultrasound in urology, the ultrasound visibility or echogenicity of various stents is not well-studied.
View Article and Find Full Text PDF