Postoperative outcomes of intraocular lens implantation in the bag versus posterior optic capture in pediatric cataract surgery.

J Cataract Refract Surg

From the Iladevi Cataract & IOL Research Centre (A.B. Vasavada, V. Vasavada, Shah, V.A. Vasavada, S.A. Vasavada, Srivastava, Sudhalkar), Ahmedabad, India; Storm Eye Institute (Trivedi), Medical University of South Carolina, Charleston, South Carolina, USA.

Published: September 2017


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To compare complications in children up to 4 years old having cataract surgery with intraocular lens (IOL) implantation using 2 techniques: in-the-bag IOL with anterior vitrectomy or optic capture of IOL with no anterior vitrectomy.

Setting: Iladevi Cataract & IOL Research Centre, Ahmedabad, India.

Design: Prospective randomized control clinical trial.

Methods: The study included children having cataract surgery with IOL implantation. Patients were randomized to Group 1 (in-the-bag 3-piece hydrophobic acrylic IOL [Acrysof MA60AC] with anterior vitrectomy) or Group 2 (optic capture of the same IOL without anterior vitrectomy). Intraoperative complications were documented. Postoperative visual axis obscuration (VAO), glaucoma, cell deposits on the IOL, and posterior synechiae were compared at 1, 3, 6, and 12 months.

Results: The study comprised 61 children (61 eyes). The mean ages were 14.8 months ±11.47 (SD) in Group 1 (n = 30) and 18.2 ± 11.47 months in Group 2 (n = 31). Overall, only 1 eye in Group 1 developed a VAO requiring membranectomy 4 months postoperatively, and 2 eyes in Group 1 developed glaucoma over 12 months (P = .49). Intraocular lens cell deposits and posterior synechiae were comparable between groups. The IOL could not be captured in 5 eyes (16.1%); no complications occurred in these eyes.

Conclusions: Optic capture of 3-piece hydrophobic acrylic IOLs could be achieved in most eyes. The VAO, glaucoma, and inflammation were comparable 12 months postoperatively. Thus, optic capture of an IOL is an alternative surgical technique that can be used to avoid vitrectomy, even in children younger than 4 years.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcrs.2017.07.022DOI Listing

Publication Analysis

Top Keywords

optic capture
20
intraocular lens
12
iol anterior
12
anterior vitrectomy
12
capture iol
12
iol
10
cataract surgery
8
iol implantation
8
3-piece hydrophobic
8
hydrophobic acrylic
8

Similar Publications

Computer-aided diagnostic (CAD) systems for color fundus images play a critical role in the early detection of fundus diseases, including diabetes, hypertension, and cerebrovascular disorders. Although deep learning has substantially advanced automatic segmentation techniques in this field, several challenges persist, such as limited labeled datasets, significant structural variations in blood vessels, and persistent dataset discrepancies, which continue to hinder progress. These challenges lead to inconsistent segmentation performance, particularly for small vessels and branch regions.

View Article and Find Full Text PDF

Background: Velocity-Based Training (VBT) is an emerging method in resistance training for objectively prescribing and monitoring training intensity and neuromuscular function. Given its growing popularity, assessing the validity and reliability of VBT devices is critical for strength and conditioning coaches.

Objective: The primary purpose of this review was twofold: (1) to identify and address methodological gaps in current assessments of VBT device validity and reliability, and (2) to propose and apply a novel, multi-layered, criterion-based framework-developed in collaboration with statisticians and domain experts-for evaluating these devices.

View Article and Find Full Text PDF

A novel medium-current (up to 20 mA), low normalized beam emittance (<1 π mm mrad) electron cyclotron resonance microwave H+ ion source has been developed at the Center for Energy Research in Budapest, Hungary. This high-stability design targets an energy ripple below 1% while delivering a continuous or pulsed proton beam with adjustable pulse duration (0.1-10 ms) and frequency (0.

View Article and Find Full Text PDF

We introduce an efficient method, TTN-HEOM, for exactly calculating the open quantum dynamics for driven quantum systems interacting with highly structured bosonic baths by combining the tree tensor network (TTN) decomposition scheme with the bexcitonic generalization of the numerically exact hierarchical equations of motion (HEOM). The method yields a series of quantum master equations for all core tensors in the TTN that efficiently and accurately capture the open quantum dynamics for non-Markovian environments to all orders in the system-bath interaction. These master equations are constructed based on the time-dependent Dirac-Frenkel variational principle, which isolates the optimal dynamics for the core tensors given the TTN ansatz.

View Article and Find Full Text PDF

Introduction: Amblyopia is a neurodevelopmental visual disorder treated with occlusion or pharmacological penalization of the dominant, non-amblyopic eye in early childhood. After early childhood, efficacy of occlusion therapy is limited due to a reduction in neuronal plasticity, and no mainstay clinical treatment is available. Selective serotonin reuptake inhibitors (SSRIs) have been hypothesized to enhance neuroplasticity in the adult brain, thereby facilitating improvements in amblyopia.

View Article and Find Full Text PDF