Article Abstract

De-noising is a substantial issue in hydrologic time series analysis, but it is a difficult task due to the defect of methods. In this paper an energy-based wavelet de-noising method was proposed. It is to remove noise by comparing energy distribution of series with the background energy distribution, which is established from Monte-Carlo test. Differing from wavelet threshold de-noising (WTD) method with the basis of wavelet coefficient thresholding, the proposed method is based on energy distribution of series. It can distinguish noise from deterministic components in series, and uncertainty of de-noising result can be quantitatively estimated using proper confidence interval, but WTD method cannot do this. Analysis of both synthetic and observed series verified the comparable power of the proposed method and WTD, but de-noising process by the former is more easily operable. The results also indicate the influences of three key factors (wavelet choice, decomposition level choice and noise content) on wavelet de-noising. Wavelet should be carefully chosen when using the proposed method. The suitable decomposition level for wavelet de-noising should correspond to series' deterministic sub-signal which has the smallest temporal scale. If too much noise is included in a series, accurate de-noising result cannot be obtained by the proposed method or WTD, but the series would show pure random but not autocorrelation characters, so de-noising is no longer needed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4215914PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0110733PLOS

Publication Analysis

Top Keywords

wavelet de-noising
16
proposed method
16
energy distribution
12
de-noising
10
energy-based wavelet
8
hydrologic time
8
series
8
time series
8
distribution series
8
wtd method
8

Similar Publications

Enhanced DWT for Denoising Heartbeat Signal in Non-Invasive Detection.

Sensors (Basel)

March 2025

Institute for Infocomm Research (I2R), Agency for Science, Technology and Research (A*STAR), Singapore 138632, Singapore.

Achieving both accurate and real-time monitoring heartbeat signals by non-invasive sensing techniques is challenging due to various noise interferences. In this paper, we propose an enhanced discrete wavelet transform (DWT) method that incorporates objective denoising quality assessment metrics to determine accurate thresholds and adaptive threshold functions. Our approach begins by denoising ECG signals from various databases, introducing several types of typical noise, including additive white Gaussian (AWG) noise, baseline wandering noise, electrode motion noise, and muscle artifacts.

View Article and Find Full Text PDF

Continuous emission monitoring system is commonly employed to monitor NOx emissions in municipal solid waste incineration (MSWI) processes. However, it still encounters the challenges of regular maintenance and measurement lag. These issues significantly impact the accurate and stable control of NOx emissions.

View Article and Find Full Text PDF

An inertial guidance system based on a fiber optic gyroscope (FOG) is an effective way to guide long-distance curved pipe jacking. However, environmental disturbances such as vibration, electromagnetism, and temperature will cause the FOG signal to generate significant random noise. The random noise will overwhelm the effective signal.

View Article and Find Full Text PDF

Gradient-based adaptive wavelet de-noising method for photoacoustic imaging in vivo.

J Biophotonics

February 2024

Hybrid Imaging System Laboratory, School of Information Science and Technology, ShanghaiTech University, Shanghai, China.

Photoacoustic imaging (PAI) has been applied to many biomedical applications over the past decades. However, the received PA signal usually suffers from poor SNR. Conventional solution of employing higher-power laser, or doing long-time signal averaging, may raise the system cost, time consumption, and tissue damage.

View Article and Find Full Text PDF

Background: Phonocardiogram (PCG) signal provides valuable information for diagnosing heart diseases. However, its applications in quantitative analyses of heart function are limited because the interpretation of this signal is difficult. A key step in quantitative PCG is the identification of the first and second sounds (S1 and S2) in this signal.

View Article and Find Full Text PDF