98%
921
2 minutes
20
Background: The accuracy of the Holladay 2 (H2) formula is well-documented. This formula requires seven variables to estimate effective lens position (ELP) for the IOL power calculation. The lens thickness (LT) value is one of the required variables. Interestingly, the IOLMaster, which is one of the most commonly used optical biometers, can provide all the required ocular variables except LT value. It has become a pertinent issue to evaluate the accuracy of theH2 formula when it is used without the LT value. The purpose of this study was to evaluate the results when using the H2 formula, without the LT value, and compare such results to those obtained using the Haigis formula and the Hoffer Q formula.
Methods: The Institutional review board (IRB) gave their approval for the conduct of this prospective comparative study. One hundred and sixty-three eyes of 143 cataract patients from the Ophthalmology Department, Siriraj Hospital, Thailand were recruited. All eyes were measured using the IOLMaster (Carl Zeiss Meditec, Jena, Germany) for keratometry (K), axial length (AL), anterior chamber depth (ACD), and horizontal white-to-white (WTW) corneal diameter. Then, the LT measurement was obtained by A-scan ultrasonography (Quantel Axis-II, Quantel Medical, USA). Every patient underwent uncomplicated phacoemulsification by a single surgeon (NC) with a single technique using a single IOL model. Post-operative refraction was obtained at 3 months. The mean absolute errors (MAEs), median absolute errors (MedAEs) and percentage of the eyes within ±0.25, ±0.50, and ±1.00 D of predicted refraction was calculated for H2 formula both with and without LT input, Haigis, and Hoffer Q formula. The results were also classified into a group of short AL (<22.0 mm), average AL (22.0 to 24.5 mm) and long AL (>24.5 mm).
Results: There was no statistically significant difference in either MAEs or MedAEs of all formulas in all AL groups including the H2 with and without LT. There was a trend toward lower MAEs and MedAEs for H2 in the long AL group. Percentage of the eyes within ±0.25, ±0.50, and ±1.00 D of predicted refraction were similar in all AL groups.
Conclusion: The preliminary results of this study showed that the H2 formula performed well even without the LT value. It was comparable to the Haigis and Hoffer Q formulas.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00417-013-2439-8 | DOI Listing |
PLoS One
September 2025
Department of Mathematics, Faculty of Science and Information Technology, Jadara University, Irbid, Jordan.
This study introduces the Wrapped Epanechnikov Exponential Distribution (WEED), a novel circular distribution derived from the Epanechnikov exponential distribution. The probability density function and cumulative distribution function are presented, together with a comprehensive analysis of its properties and parameters, including the characteristic function and trigonometric moments. Parameters are estimated using maximum likelihood estimation (MLE).
View Article and Find Full Text PDFCrit Rev Food Sci Nutr
September 2025
State Key Laboratory of Southwestern Chinese Medicine Resources, School of Pharmacy, Chengdu University of Traditional Chinese Medicine, Chengdu, P. R. China.
Natural products have emerged as a vital source of active ingredients in medicine, food, and cosmetics due to their unique biological activities, safety profiles, and sustainability. However, most bioactive compounds in natural products are intensely bitter, limiting their use in pharmaceuticals and foods. The bitter taste attributes vary markedly among different compound classes, predominantly due to their structural characteristics.
View Article and Find Full Text PDFAnn Afr Med
September 2025
Department of Orthopaedics, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, Karnataka, India.
Introduction: Pediatric endotracheal intubation is challenging due to airway anatomical differences. Accurate endotracheal tube (ETT) sizing is crucial for effective ventilation and preventing complications. Traditional age, weight, or height-based methods are often unreliable, leading to multiple attempts.
View Article and Find Full Text PDFProc Natl Acad Sci U S A
September 2025
McKetta Department of Chemical Engineering, The University of Texas at Austin, Austin, TX 78712.
Many soft, tough materials have emerged in recent years, paving the way for advances in wearable electronics, soft robotics, and flexible displays. However, understanding the interfacial fracture behavior of these materials remains a significant challenge, owing to the difficulty of quantifying the respective contributions from viscoelasticity and damage to energy dissipation ahead of cracks. This work aims to address this challenge by labeling a series of polymer networks with fluorogenic mechanophores, subjecting them to T-peel tests at various rates and temperatures, and quantifying their force-induced damage using a confocal microscope.
View Article and Find Full Text PDFProc Natl Acad Sci U S A
September 2025
Department of Bioengineering, Stanford University, Stanford, CA 94305.
Despite periods of permanent darkness and extensive ice coverage in polar environments, photosynthetic ice diatoms display a remarkable capability of living inside the ice matrix. How these organisms navigate such hostile conditions with limited light and extreme cold remains unknown. Using a custom subzero temperature microscope during an Arctic expedition, we present the finding of motility at record-low temperatures in a Eukaryotic cell.
View Article and Find Full Text PDF