Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Purpose: At 1.5 T, diffusion-weighted imaging-fluid-attenuated inversion recovery (DWI-FLAIR) mismatch helps identify strokes within 4.5 hours of onset. However, at 3T, studies have found divergent results. The goal of this study was to determine whether DWI-FLAIR mismatch at 3T would also be helpful for identifying patients within 4.5 hours of symptom onset.

Methods: All patients presenting with an ischemic stroke in the middle cerebral artery territory and explored with 3T MRI within 12 hours between November 2007 and April 2012 were included in this retrospective study. Two readers analyzed the DWI and FLAIR images. Logistic regression was performed to determine independent predictors of FLAIR visibility. Also, the predictive values of a mismatch for identifying patients with stroke onset ≤4.5 hours were estimated.

Results: The study included 194 patients. The only predictive factor of FLAIR visibility was delayed MRI acquisition. The DWI-FLAIR mismatch was able to identify patients within 4.5 hours of stroke onset with relatively low sensitivity (0.55; 95% confidence interval, 0.48-0.63), low specificity (0.60; 95% confidence interval, 0.42-0.77), high positive predictive value (0.88; 95% confidence interval, 0.82-0.94), and very low negative predictive value (0.19; 95% confidence interval, 0.11-0.28). In addition, 44.5% of patients had a positive FLAIR sequence within 4.5 hours.

Conclusions: This study improves our understanding of DWI-FLAIR mismatch as an imaging biomarker for wake-up management of patients with stroke. At 3T, the presence of a DWI-FLAIR mismatch was able to identify stroke onset of <4.5 hours. However, 44.5% of such stroke cases demonstrated FLAIR signal changes.

Download full-text PDF

Source
http://dx.doi.org/10.1161/STROKEAHA.113.001001DOI Listing

Publication Analysis

Top Keywords

inversion recovery
8
diffusion-weighted imaging-fluid-attenuated
4
imaging-fluid-attenuated inversion
4
recovery mismatch
4
mismatch positive
4
positive diffusion-weighted
4
diffusion-weighted imaging/negative
4
imaging/negative fluid-attenuated
4
fluid-attenuated inversion
4
recovery tesla
4

Similar Publications

Purpose: Gadoxetic acid-enhanced hepatobiliary phase T-weighted (Tw) MRI is effective for the detection of focal liver lesions but lacks sufficient T contrast to distinguish benign from malignant lesions. Although the addition of T, diffusion, and dynamic contrast-enhanced Tw imaging improves lesion characterization, these methods often do not provide adequate spatial resolution to identify subcentimeter lesions. This work proposes a high-resolution, volumetric, free-breathing liver MRI method that produces colocalized fat-suppressed, variable Tw images from a single acquisition, thereby improving both lesion detection and characterization.

View Article and Find Full Text PDF

Comparative clinical efficacy of nickel-titanium shape memory staples versus miniplate for Bartoníček-Rammelt type III and IV posterior malleolar fractures. A retrospective analysis of 47 consecutive patients treated between January 2022 and June 2024 documented operative time, intraoperative blood loss, fluoroscopy times, healing time, complications, postoperative fracture gap distance (mm), and articular surface step-off (mm) at the ankle joint. Ankle function was assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, the Manchester-Oxford Foot Questionnaire (MOXFQ), and range of motion measurements at 3, 6, 12, and 14 months.

View Article and Find Full Text PDF

Positron Emission Tomography (PET) is a critical imaging modality in nuclear medicine but requires radioactive tracer administration, which increases radiation exposure risks. While recent studies have investigated MR-guided low-dose PET denoising, they neglect two critical factors: the synergistic roles of multicontrast MR images and disease-specific denoising requirements. In this work, we propose a diffusion model that integrates T1-weighted, T2 fluid attenuated inversion recovery (T2 FLAIR), and hippocampal-optimized (T2 HIPPO) MR sequences to achieve ultra-low-dose PET denoising tailored for temporal lobe epilepsy (TLE).

View Article and Find Full Text PDF

ObjectivesThe objective of this study was to evaluate the occurrence of voltage-gated potassium channel (VGKC) antibodies and the pattern of MRI changes in cats with complex partial seizures with orofacial involvement (CPSOFI), as well as to investigate whether there are factors influencing survival that could be used as prognostic markers in those cats.MethodsCats with CPSOFI were identified retrospectively. The following data were retrieved from the hospital database: signalment, age at first seizure and presentation, the presence of antibodies against VGKC (leucine-rich glioma inactivating factor 1 (LGI1), contactin-associated protein 2 (CASPR2)) and cerebrospinal fluid (CSF) analysis findings.

View Article and Find Full Text PDF

Direct myelin imaging with inversion-recovery ultrashort-echo-time (IR-UTE) is highly motion-sensitive, yet extra hardware or longer scans are impractical. We evaluated whether a superior-inferior (SI) self-navigator with bit-reversed spoke-angles mitigates motion artifacts without extending acquisition. Dual-echo IR-UTE was implemented at 3T.

View Article and Find Full Text PDF