98%
921
2 minutes
20
The intrusion of moisture into landfills can pose a health hazard because of the possibility that the moisture will carry harmful substances into the groundwater. Early detection of moisture anywhere within these landfills is essential if corrective action is to be taken well before an occurrence of this kind. This paper presents the results of a field-scale simulation test of the use of fiber optics to detect the presence of moisture within landfill covers, using a detection method based on the thermal response of soils as a function of their moisture content. By sending electrical current through an embedded stainless-steel tube, soils of varying moisture content were heated and time-dependent temperature measurements were obtained with a fiber-optic distributed temperature sensor system. The optical fiber itself lay within the tube, but its temperature was a function of how rapidly heat was conducted into the surrounding medium. The results of this experiment, which are in agreement with those obtained using more traditional "point" sampling and laboratory analysis, are presented along with the strengths and limitations of the thermal-response method of detecting moisture.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/10473289.2003.10466268 | DOI Listing |
J Am Chem Soc
September 2025
Center for Nanochemistry, Beijing Science and Engineering Center for Nanocarbons, Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing 100871, China.
Incorporating atomically thin two-dimensional (2D) materials with optical fibers expands their potential for optoelectronic applications. Recent advancements in chemical vapor deposition have enabled the batch production of these hybrid fibers, paving the way for practical implementation. However, their functionality remains constrained by the integration of a single 2D material, restricting their versatile performance.
View Article and Find Full Text PDFJ Int Med Res
September 2025
Department of Anesthesiology, Lishui People's Hospital, China.
ObjectiveThe sedation protocol for flexible fiberoptic bronchoscopy has long been a matter of inconclusiveness. The aim of this study was to evaluate the safety and efficacy of remimazolam combined with alfentanil in flexible fiberoptic bronchoscopy and provide insights for optimizing clinical anesthesia strategies.MethodsThis study was a randomized, single-blind controlled trial.
View Article and Find Full Text PDFAdv Mater
September 2025
Key Laboratory of In-Fiber Integrated Optics of Ministry of Education, College of Physics and Optoelectronic Engineering, Harbin Engineering University, Harbin, 150001, China.
Recently, joint replacement surgery is facing significant challenges of patient dissatisfaction and the need for revision procedures. In-situ monitoring of stress stability at the site of artificial joint replacement during postoperative evaluation is important. Mechanoluminescence (ML), a novel "force to light" conversion technology, may be used to monitor such bio-stress within tissues.
View Article and Find Full Text PDFInt Ophthalmol
September 2025
Beijing Tongren Eye Center, Beijing Tongren Hospital, Beijing key Laboratory of Intraocular Tumor Diagnosis and Treatment, Beijing Ophthalmology and Visual Sciences Key Lab, Medical Artificial Intelligence Research and Verification Key Laboratory of the Ministry of Industry and Information Technolog
Purpose: To analyze macular microvascular networks and investigate correlations between visual acuity and quantitative parameters in patients with Leber's hereditary optic neuropathy (LHON) using optical coherence tomography angiography (OCTA).
Methods: An observational, cross-sectional study was conducted, including 25 eyes from 25 genetically confirmed chronic LHON patients and 25 eyes from 25 age-matched healthy controls. Images were obtained using a spectral domain OCTA system.
ACS Appl Nano Mater
August 2025
Department of Physics, School of Science and Technology, Nottingham Trent University, Nottingham NG11 8NS, United Kingdom.
Accurate and noninvasive detection of cancer cells is critical for advancing early stage cancer diagnostics and monitoring tumor progression. While manual enumeration methods, such as hemocytometry, remain in use, they suffer from limited sensitivity and scalability. In this article, we report the first feasibility study demonstrating a graphene oxide (GO)-functionalized long-period fiber grating (LPG) sensor for the label-free detection of MCF-7 human breast cancer cell density via secreted cellular byproducts.
View Article and Find Full Text PDF