This study presents the first synthesis and characterization of quinoliporphyrin (), a unique aromatic monoanionic macrocycle featuring a quinoline unit within the porphyrinoid core. Previously, quinoline-containing porphyrins had their quinoline units positioned at peripheral locations. This structural feature exhibits exclusive reactivity with Cu, leading to rapid degradation at μM concentrations within 30 min at room temperature and the formation of a fluorogenic product ().
View Article and Find Full Text PDFThis retrospective cohort study compared the outcomes (postoperative pain, morphine consumption, sleep disturbance, and function) of patients undergoing arthroscopic rotator cuff repair involving either continuous interscalene block (CISB group) or single-injection interscalene block with intravenous dexmedetomidine (SISB group) analgesia. : This study included 61 patients, aged 59-71 years, who underwent elective arthroscopic rotator cuff repair and for whom complete electronic health records were available. Patients in the SISB group received a single-injection nerve block plus intraoperative intravenous dexmedetomidine and postoperative patient-controlled analgesia (PCA; morphine and dexmedetomidine; = 33).
View Article and Find Full Text PDFJ Electron Mater
February 2025
We carried out a short beamtime at the Pohang Accelerator Laboratory x-ray Free Electron Laser to perform a pump-probe (PP) laser excitation diffraction experiment on the silicon (222) forbidden Bragg peak. To limit the x-ray penetration, we used a "device layer" silicon film wafer bonded to a silicon substrate. The sample, specially fabricated by MEMC Electronic Materials, had a Si(100) substrate bonded to a 170 nm Si(100) film rotated at 45° for crystallographic isolation.
View Article and Find Full Text PDFMicromachines (Basel)
April 2025
A spiral microfluidic chip (SMC) and multi-spiral microfluidic chip (MSMC) for lipid nanoparticle (LNP) production were fabricated using a CO laser engraving method, using perfluoropolyether (PFPE) and poly(ethylene glycol) diacrylate as photopolymerizable base materials. The SMC includes a spiral microchannel that enables rapid fluid mixing, thereby facilitating the production of small and uniform LNPs with a size of 72.82 ± 24.
View Article and Find Full Text PDFUnderstanding atomic-level imperfections is crucial in various technological applications. Bragg coherent X-ray diffraction imaging (BCDI) enables non-destructive, three-dimensional imaging of those materials under in situ and operando conditions but has limited spatial resolution. This limitation hinders accurate calculations of physical quantities, e.
View Article and Find Full Text PDFBackground: Allogenous dermal scaffold augmentation enhances partial rotator cuff repairs by providing structural support and a biologic scaffold that promotes tissue regeneration, reduces mechanical strain, and compensates for poor tendon quality in large to massive rotator cuff tears. This approach helps lower the risk of retear and improves functional recovery.
Methods: This study included 55 patients with large to massive rotator cuff tears, divided into two groups.
Micromachines (Basel)
January 2025
Microfluidic devices are greatly affected by the materials used. The materials used in previous studies had problems in various aspects, such as processing, adsorption, and price. This study will investigate the materials needed to overcome such problems.
View Article and Find Full Text PDFDisordering atomic structures offers a functionality hardly expected in ordered states, including phase-change memory and photonic computing, offering the potential to renovate von Neumann architecture for neuromorphic engineering with low latency. However, significant energy consumption during the disordering compromises the data reliability and integration efficiency, which is traditionally regarded to take place after melting. Here, we investigate time for disordering in isochronal and isochoric manners, challenging the conventional melt-quenching theory.
View Article and Find Full Text PDF: We have applied an anterior locking compression mini plate in addition to a conventional superior locking compression plate for the treatment of wedge or multifragmentary clavicular fractures. : Medical and radiologic data were retrospectively reviewed for patients who underwent surgical fixation with an anterior locking compression mini plate and conventional anatomical locking compression plate in a clavicle fracture of AO/OTA 15.2 B and 15.
View Article and Find Full Text PDFTo evaluate the clinical and radiologic outcomes of arthroscopic augmented partial repair (APR) with acellular dermal matrix versus arthroscopic superior capsular reconstruction (SCR) in massive rotator cuff tears. The study included a total of 49 patients with massive rotator cuff tears who underwent arthroscopic APR (26 patients) and SCR (23 patients) between March 2018 and June 2021. Clinical scores, visual analog scores, and range of motion were collected preoperatively and postoperatively until the last follow-up.
View Article and Find Full Text PDFIn this paper, a novel thermo-optic metagrating based on phase-change material (vanadium dioxide, VO) is proposed for broadband, polarization-independent, and non-dispersive transmission modulation at the telecommunication wavelengths. In the pursuit of concurrent attainment of multiple performance objectives, nanostructured VO metagratings are optimized numerically using inverse design algorithms. Notably, adjoint optimization pertaining to both phases of VO facilitates better modulation capabilities within free-form shaped VO metagratings compared to shape-optimized methods with predetermined designs.
View Article and Find Full Text PDFMobile-bearing (MB) total knee arthroplasty (TKA) implants were introduced as an alternative to fixed-bearing (FB) implants because of their theoretical advantages related to femorotibial rotational mismatch. The purpose of this study is to compare the clinical and radiologic outcomes of MB and FB TKA after approximately 13 years of follow-up. We compared the results of 88 patients with a mean age of 66 years who had received a rotating platform MB implant or a FB implant.
View Article and Find Full Text PDFA mild and efficient method for the copper-catalyzed diamination of alkenes is described. In this reaction, -benzoylhydroxylamine serves as an electrophilic nitrogen source for the regioselective formation of C-N bonds. This transformation provides a novel strategy for synthesizing all four isomeric 2,3-disubstituted azaindoline families and offers a wide substrate scope.
View Article and Find Full Text PDFMicromachines (Basel)
April 2024
A perfluoropolyether (PFPE)-based microfluidic device with cross-junction microchannels was fabricated with the purpose of producing uniform droplets. The microchannels were developed using CO laser engraving. PFPE was chosen as the main material because of its excellent solvent resistance.
View Article and Find Full Text PDFObjective: Major lower extremity amputation (LEA) such as below-knee or above-knee amputations can result in more physical disabilities and poorer socioeconomic functions than minor LEAs in diabetic foot ulcer (DFU). Therefore, identification of risk factors for major LEA and investigation of effectiveness of endovascular revascularization are critical for prevention and better prognosis of DFU patients.
Methods: From January 2014 to December 2017, a total of 125 patients with DFU treated with any level of amputation were included in this study.
Knee Surg Sports Traumatol Arthrosc
April 2024
Purpose: This study aimed to compare the 5-year clinical and functional outcomes, including repaired tendon healing status, between early and delayed rehabilitation after arthroscopic rotator cuff repair METHODS: A total of 75 patients with rotator cuff tears (less than 5 cm) underwent arthroscopic repairs over a 60-month period. Participants were randomly assigned to early and delayed postoperative rehabilitation groups with distinct protocols. Clinical and functional outcome measures included Constant score, University of California at Los Angeles (UCLA) score, visual analogue scale for pain and isokinetic dynamometer test for muscle strength recovery.
View Article and Find Full Text PDFDetermining the aromaticity of various fluorinated benzenes is challenging as easily obtained experimental aromaticity [Δδ( - )] necessitates the chemical shifts of inner and outer protons. This issue was addressed in porphyrinoids by replacing the electron-withdrawing (E.W.
View Article and Find Full Text PDFMixed-lineage protein kinase 3 (MLK3) is implicated in several human cancers and neurodegenerative diseases. A series of 3H-imidazo[4,5-b]pyridine derivatives were designed, synthesized and evaluated as novel MLK3 inhibitors. A homology model of MLK3 was developed and all designed compounds were docked to assess their binding pattern and affinity toward the MLK3 active site.
View Article and Find Full Text PDFThis study aimed to assess the performance of an artificial intelligence (AI) model for predicting clinical pregnancy using enhanced inner cell mass (ICM) and trophectoderm (TE) images. In this retrospective study, we included static images of 2555 day-5-blastocysts from seven in vitro fertilization centers in South Korea. The main outcome of the study was the predictive capability of the model to detect clinical pregnancies (gestational sac).
View Article and Find Full Text PDFJ Cell Physiol
April 2024
The NOD-, LRR-, and Pyrin domain-containing protein 3 (NLRP3) inflammasome plays key roles in regulating inflammation. Numerous studies show that the abnormal activation of NLRP3 associates with the initiation and progression of various diseases. Hence, the NLRP3 inflammasome may be a promising therapeutic target for these diseases.
View Article and Find Full Text PDFBMC Musculoskelet Disord
December 2023
Background: We have applied primarily multiple locking compression miniplates in treating multifragmentary, comminuted patellar fracture in combination with conventional fixation methods.
Methods: Medical and radiologic data were retrospectively reviewed for the patients surgically fixated with locking compression miniplates in patellar fracture of AO/OTA 34-C3. The primary outcome was bone union at the final follow-up, and the secondary outcomes were functional outcomes and postoperative complications associated with the procedure.
The structures, strain fields, and defect distributions in solid materials underlie the mechanical and physical properties across numerous applications. Many modern microstructural microscopy tools characterize crystal grains, domains and defects required to map lattice distortions or deformation, but are limited to studies of the (near) surface. Generally speaking, such tools cannot probe the structural dynamics in a way that is representative of bulk behavior.
View Article and Find Full Text PDFWe demonstrated temperature-insensitive, label-free detection of SARS-CoV-2 spike protein (SSP) by harnessing the complementary refractive index and temperature dependence of multi-mode interference (MMI) created by a no-core fiber (NCF) and phase-matched resonance generated by a long-period fiber grating (LPFG). To combine MMI and grating resonance, primarily sensitive to the surrounding medium refractive index (SMRI) and ambient temperature, respectively, a fiber-optic transducer was fabricated by splicing an NCF segment with an LPFG inscribed on double-clad fiber. The transducer was functionalized with human ACE2 receptors to selectively capture SSP.
View Article and Find Full Text PDFHerein, we investigated the potential of plasma-activated water (PAW) as a wash solution for the microbial decontamination of cherry tomatoes. We analyzed the efficacy of PAW as a bactericidal agent based on reactive species and pH. Immersion for 5 min in PAW15 (generated via plasma activation for 15 min) was determined as optimal for microbial decontamination of fresh produce.
View Article and Find Full Text PDFNano Lett
September 2023
A new type of microfluidic bioreactor with fibrous micromixers for the ingredient mixing and a long macrochannel for the in vitro transcription reaction was fabricated for the continuous production of mRNA. The diameter of the fibrous microchannels in the micromixers was tuned by using an electrospun microfibrous disc with different microfiber diameters. The micromixer with a larger diameter of fibrous microchannels exhibited a better mixing performance than the others.
View Article and Find Full Text PDF