Publications by authors named "Ho-Kyung Lim"

Objectives: Dental implants have become more straightforward and convenient with advancements of digital technology in dentistry. Implant planning utilizing artificial intelligence (AI) has been attempted, yet its clinical efficacy remains underexplored. We aimed to assess the clinical applicability of AI-based implant planning software as a decision-support tool in comparison with those placed by clinicians which were clinically appropriate in their three-dimensional positions.

View Article and Find Full Text PDF

Objectives: This study aims to evaluate the effect of applying extra positive air pressure (AP) in dental handpieces (HPs) on preventing external bacterial penetration.

Materials And Methods: To investigate the suck-back phenomenon during HP operation, we examined the correlation between AP variations and the occurrence of suck-back under controlled conditions. To assess the suck-back phenomenon during HP operation, AP changes were evaluated by monitoring water displacement using a glass tube or a manometer.

View Article and Find Full Text PDF

The use of biodegradable materials in bone plates offers remarkable advantages; however, their application in bone fixation is limited by their brittleness. Moreover, treatments tailored to patient conditions are needed in orthopedics. In this study, bone plates were fabricated with stereocomplex polylactic acid (scPLA) and the effects of poly(d-lactic acid) molecular weight and scPLA blending ratios were analyzed.

View Article and Find Full Text PDF

To assess the incidence of and risk factors for black triangles between the central incisors after orthodontic treatment; Methods: Ninety-seven post-treatment patients (29 men and 68 women; mean age, 22.7 years) were retrospectively divided into two groups based on the presence or absence of black triangles, using intraoral photographs. Based on the Jemt Index, the black triangle occurrence group was further classified into mild, moderate, and severe groups.

View Article and Find Full Text PDF

This study assessed the accuracy and reliability of artificial intelligence (AI)-reconstructed images of two-dimensional (2D) lateral cephalometric analyses of facial computed tomography (CT) images, which is widely used for the diagnosis of craniofacial deformities and in the planning of their treatment. Facial CT datasets from 40 patients were collected. Original 1 mm slices were reformatted to 3 mm, and then an AI algorithm reconstructed the 3 mm slices and converted them back to 1 mm to generate lateral cephalometric images.

View Article and Find Full Text PDF

(1) Background: To compare the degree of conversion of resin cores in various types of cavities and determine an effective irradiation method for achieving a higher degree of conversion. (2) Methods: Four different-sized cavities (narrow-shallow, narrow-deep, wide-shallow, and wide-deep) were simulated using a Teflon mold. The light irradiance reaching the bottom of each mold was measured by positioning a radiometer.

View Article and Find Full Text PDF

Purpose: This experiment aimed to observe the differences in biological properties by producing BGS-7 + PCL scaffolds with different weight fractions of BGS-7 through 3D printing and to confirm whether using the scaffold for vertical bone augmentation is effective.

Materials And Methods: Cube-shaped bioglass (BGS-7) and polycaprolactone (PCL) scaffolds with different weight fractions (PCL alone, PCL with 15% and 30% BGS-7) are produced using 3D printing. The surface hydroxyapatite (HA) apposition, the pH change, proliferation and attachment assays, and various gene expression levels are assessed.

View Article and Find Full Text PDF

This study aimed to measure masticatory performance (MP) using β-carotene gummy jelly to investigate its relationship with skeletal properties in decompensated patients diagnosed with skeletal class III malocclusion. The study included 78 patients (38 men and 40 women) diagnosed with skeletal class III malocclusion without temporomandibular joint disorder and periodontal disease. MP was measured using a new masticatory measuring device and β-carotene in the gummy jelly.

View Article and Find Full Text PDF

This study aimed to investigate the effects of shift work on periodontal disease in blue-and white-collar workers and to examine the interaction effects between occupation and work patterns. Data were collected from the Korea National Health and Nutrition Examination Survey conducted by the Korean Ministry of Health and Welfare for a total of nine years from 2007 to 2015. Participants with missing outcome variables were excluded from the analysis and a total of 32,336 participants were included in the final analysis.

View Article and Find Full Text PDF

The aim of this study was to convert medical images stored in 3 mm slices in the picture archiving and communication system (PACS) to 1 mm slices, using artificial intelligence (AI), and to analyze the accuracy of the AI. The original 1.0 mm CT slices of the facial bone were obtained from 30 patients and reformatted to a rough CT slice of 3.

View Article and Find Full Text PDF

Objectives: This study aimed to evaluate the effect of aging on the changes in implant stability over time following implant placement.

Materials And Methods: A total of 104 patients in four age ranges (group 1: <60 years, group 2: 61-70 years, group 3: 71-80 years, and group 4: >80 years) were included. Bone-level tapered implants were placed without implementing any bone augmentation procedure.

View Article and Find Full Text PDF

Background: The objectives of this study were to use a digital camera to measure the discoloration of orthodontic elastomeric chains in various immersion solutions over different time periods and to determine the valid acceptability tolerances for color changes in orthodontic elastomeric chains by surveying digital photographs.

Methods: Orthodontic elastomeric chains were applied to the maxillary anterior teeth of nine typodont models. The models were divided into three groups and immersed in the curry, coffee, and wine solutions.

View Article and Find Full Text PDF

To evaluate the stability of a dental implant and the effectiveness of a newly designed damping capacity assessment device by improving the number of blows and strength evaluated by a prospective clinical study. The stability of dental implants was measured in 50 implants in a total of 38 patients. Measurements were performed using Anycheck and Periotest M devices, twice in total, divided into buccal and lingual directions.

View Article and Find Full Text PDF

(1) Background: The purpose of this study was to evaluate the 3-dimensional bony changes of the mandibular condyle in temporomandibular joints-osteoarthritis (TMJ-OA) patients treated with stabilization splint (SS) therapy using shape correspondence analysis. (2) Methods: A total of 27 adult patients (2 men and 25 women) with a mean age of 24.6 ± 3.

View Article and Find Full Text PDF

The objective of this retrospective study is to verify the effectiveness and safety of patient-specific titanium implants on maxillofacial bones, with a long-term follow-up. Total 16 patients with various maxillofacial defects underwent reconstruction using patient-specific titanium implants. Titanium implants, manufactured by electron beam melting, selective laser sintering, or milling, were inserted into the maxilla, mandible, or zygoma.

View Article and Find Full Text PDF

Occlusal displacement often occurs after surgery for condylar process fractures because it is difficult to reduce these fractures precisely. However, performing semi-rigid fixation using a sliding plate may overcome this limitation. A retrospective clinical comparison between semi-rigid and rigid fixations was performed.

View Article and Find Full Text PDF

Background: The inferior alveolar nerve (IAN) innervates and regulates the sensation of the mandibular teeth and lower lip. The position of the IAN should be monitored prior to surgery. Therefore, a study using artificial intelligence (AI) was planned to image and track the position of the IAN automatically for a quicker and safer surgery.

View Article and Find Full Text PDF

This study aimed to evaluate the bone regeneration capacity of a customized alloplastic material and xenograft with recombinant human bone morphogenetic protein-2 (rhBMP-2). We prepared hydroxyapatite (HA)/tricalcium phosphate (TCP) pure ceramic bone blocks made using a 3D printing system and added rhBMP-2 to both materials. In eight beagle dogs, a total of 32 defects were created on the lower jaws.

View Article and Find Full Text PDF

Our aim was to investigate the bone regeneration capacity of powder-type biphasic ceramic scaffold (BCP powder), block-type BCP (BCP block), and collagen-added block-type BCP (BCP collagen) with different concentrations of recombinant human bone morphogenetic protein 2 (rhBMP-2) in an animal model. Four rabbits were assigned to each of the following groups: no graft + rhBMP-2 (0.1/0.

View Article and Find Full Text PDF

: The aim of our study was to test whether wide diameter (6 mm) implants perform differently from standard diameter (4 mm) implants in terms of marginal bone level and survival rate. : Our sample comprised 72 patients who underwent surgery; a total of 80 implants were placed in the maxillary or mandibular molar region. Patients were divided into two groups according to the diameter of the implant, and were followed up for six years after the final setting of the prosthetics.

View Article and Find Full Text PDF

This prospective study was undertaken to evaluate the clinical usefulness of a newly developed one-piece, screw-free, and micro-locking implant system, which was designed to overcome the shortcomings of the existing implant systems. Thirty-eight patients were recruited and randomly and equally assigned to an experimental group (micro-locking one-piece fixture, MLF; = 19) or a control group (micro-locking abutment, MLA). Cumulative implant survival rates, marginal bone resorptions, probing depths, plaque indices, bleeding indices, and complications were obtained by using clinical and radiographic findings at 6 months and 12 months after prosthesis placement.

View Article and Find Full Text PDF

In porous titanium scaffolds manufactured via 3D printing, the differences in bone formation according to pore design and implantation period were studied. Titanium scaffolds with three types of different pore structures (Octadense, Gyroid, and Dode) were fabricated via 3D printing using the selective laser melting method. Mechanical properties of scaffolds were investigated.

View Article and Find Full Text PDF

The spread and application of computer-aided design/computer-aided manufacturing (CAD/CAM) technology have contributed to the rapid development of digitalization in dentistry. The accuracy of scan results is closely related to the devising subsequent treatment plans and outcomes. Professional standards for evaluating scanners are specified in the American National Standard/American Dental Association Standard 132 (ANSI/ADA No.

View Article and Find Full Text PDF

Aim: This study aimed to investigate the association between work patterns and periodontal disease.

Materials And Methods: Data were collected from the Korea National Health and Nutrition Examination Survey between 2007 and 2012, and data from 22,508 subjects aged ≥19 years were included. An individual's work pattern was classified as either daytime or shift work.

View Article and Find Full Text PDF

This study evaluated the bone regeneration capacity and mechanical properties of block-type hydroxyapatite (HA)/tricalcium phosphate (TCP) scaffolds in response to different concentrations of polydeoxyribonucleotide (PDRN) and recombinant human bone morphogenic protein 2 (rhBMP-2). Thirty-two male white rabbits were used as a model of calvarial bone defect and classified into eight groups according to type and concentration of growth factor administered, viz., control group (only HA/TCP scaffold), scaffold + PDRN (0.

View Article and Find Full Text PDF