A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Extra Positive Air Pressure to Prevent Microbial Contamination in Dental Handpieces: An Experimental Study. | LitMetric

Extra Positive Air Pressure to Prevent Microbial Contamination in Dental Handpieces: An Experimental Study.

Int Dent J

SKKU Advanced Institute of Nanotechnology (SAINT), Sungkyunkwan University (SKKU), Suwon, Republic of Korea; Department of Nano Science and Technology, Sungkyunkwan University (SKKU), Suwon, Republic of Korea; Department of Nano Engineering, Sungkyunkwan University (SKKU), Suwon, Republic of Korea.

Published: August 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: This study aims to evaluate the effect of applying extra positive air pressure (AP) in dental handpieces (HPs) on preventing external bacterial penetration.

Materials And Methods: To investigate the suck-back phenomenon during HP operation, we examined the correlation between AP variations and the occurrence of suck-back under controlled conditions. To assess the suck-back phenomenon during HP operation, AP changes were evaluated by monitoring water displacement using a glass tube or a manometer. An extra AP supplier (EAPS) was connected to the exhaust airlines of the HP and operated for 5 seconds to control AP. To evaluate whether AP control could prevent bacterial penetration into the HP, bioburden tests were conducted by immersing the HP in five bacterial cultures during operation. This allowed for the assessment of microbial contamination risk under different AP-controlled conditions.

Results: The manometer measurements revealed a maximum negative AP of -2.11 kPa immediately after HP operation and gradually decreased over the next 9 seconds. However, no negative AP was observed when the EAPS was activated after the HP operation. Bacteria were detected on the internal HP components when extra positive AP was not sufficiently applied following the HP operation.

Conclusion: If sufficient extra positive AP is not applied after HP operation, bacteria can penetrate the HP, posing a risk of microbial contamination. However, applying extra positive AP of at least 0.1 MPa to the exhaust airflow for a minimum of 5 seconds effectively prevents microbial contamination.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12345249PMC
http://dx.doi.org/10.1016/j.identj.2025.100917DOI Listing

Publication Analysis

Top Keywords

extra positive
20
microbial contamination
16
positive air
8
air pressure
8
dental handpieces
8
applying extra
8
suck-back phenomenon
8
phenomenon operation
8
operation bacteria
8
positive applied
8

Similar Publications