A convenience that is desirable in diffuse reflectance spectroscopy (DRS) is to recover the spectral absorption by direct model inversion to facilitate decomposition of spectrally significant chromophores. Attaining such convenience that requires a simple forward model has been challenging in non-contact DRS, for assessing myoglobin forms, which is important to the evaluation of discoloration of meat. This work demonstrates that non-contact DRS configured in a center-illuminated-area-detection (CIAD) geometry [Appl.
View Article and Find Full Text PDFUnderstanding scattering insensitiveness in diffuse reflectance spectroscopy (DRS) will be useful to enhancing the spectral specificity to absorption. In DRS based on center-illuminated-area-detection (CIAD), the scattering response can saturate as the relative strength of scattering with respect to the collection size, represented by a dimensionless reduced scattering, increases over a threshold. However, the formation of saturation versus the same range of dimensionless reduced scattering may differ between a fixed reduced scattering over an increasing collection size (case 1) and an increasing reduced scattering over a fixed collection size (case 2), due to the absorption.
View Article and Find Full Text PDFMeat discoloration starts at the interface between the bright red oxymyoglobin layer and the interior deoxymyoglobin layer. Currently, limited tools are available to characterize myoglobin forms formed within the sub-surface of meat. The objective was to demonstrate a needle-probe based single-fiber reflectance (SfR) spectroscopy approach for characterizing sub-surface myoglobin forms of beef psoas major muscles during retail storage.
View Article and Find Full Text PDFThis part proposes a model of time-dependent diffuse photon remission for the center-illuminated-area-detection (CIAD) geometry, by virtue of area integration of the radially resolved time-dependent diffuse photon remission formulated with the master-slave dual-source scheme demonstrated in Part I for steady-state measurements. The time-domain model is assessed against Monte Carlo (MC) simulations limiting to only the Heyney-Greenstein scattering phase function for CIAD of physical scales and medium properties relevant to single-fiber reflectance (SfR) and over a 2 ns duration, in compliance with the timespan of the only experimental report of SfR demonstrated with a 50 µm gradient index fiber. The time-domain model-MC assessments are carried out for an absorption coefficient ranging three orders of magnitude over [0.
View Article and Find Full Text PDFDiffuse photon remission associated with the center-illuminated-area-detection (CIAD) geometry has been useful for non-contact sensing and may inform single-fiber reflectance (SfR). This series of work advances model approaches that help enrich the understanding and applicability of the photon remission by CIAD. The general approach is to derive the diffuse photon remission by the area integration of the radially resolved diffuse reflectance while limiting the analysis to a medium exhibiting only the Heyney-Greenstein (HG) scattering phase function.
View Article and Find Full Text PDFRobust models for single-fiber reflectance (SFR) are relatively complex [Opt. Lett.45, 2078 (2020)OPLEDP0146-959210.
View Article and Find Full Text PDFThe Kubelka-Munk (KM) theory of diffuse photon remission from opaque media is widely applied to quality-control processes. Recent works based on radiative transfer revealed that the KM function as the backbone parameter of the method may saturate at strong absorption to cause the KM approach to be unfit to predict the change of diffuse reflectance from the medium at strong absorption. We demonstrate by empirical means based on Monte Carlo results that diffuse photon remission from a strong-absorbing medium depends simply upon the absorption/scattering ratio when evaluated over a large area centered at the point of illumination differing in geometry from those convenient for the KM approach.
View Article and Find Full Text PDFModel approximation is necessary for reflectance assessment of tissue at sub-diffusive to non-diffusive scale. For tissue probing over a sub-diffusive circular area centered on the point of incidence, we demonstrate simple analytical steady-state total diffuse reflectance from a semi-infinite medium with the Henyey-Greenstein (HG) scattering anisotropy (factor $g$g). Two physical constraints are abided to: (1) the total diffuse reflectance is the integration of the radial diffuse reflectance; (2) the radial and total diffuse reflectance at $g \gt {0}$g>0 analytically must resort to their respective forms corresponding to isotropic scattering as $g$g becomes zero.
View Article and Find Full Text PDFWe demonstrate diffuse reflectance spectroscopy (DRS) of a subsurface tubular inclusion by using a fiber probe having a single source-detector pair attached to a laparoscopic bipolar device. A forward model was also developed for DRS sensing of an underlying long absorbing tubular inclusion set in parallel to the tissue surface, normal to the line of sight of the source-detector pair, and equidistant from the source and the detector. The model agreed with measurements performed at 500 nm and using a 10 mm source-detector separation (SDS) on an aqueous tissue phantom embedding a tubing of 2 or 4 mm inner diameter that contained 9.
View Article and Find Full Text PDFWe correct one typographical error that has occurred in four equations in Med Phys, 2013. 40(6): p. 063301.
View Article and Find Full Text PDFThe target level photobiomodulation (PBM) irradiances along the thoracic to lumbar segment of the interior spinal canal in six cadaver dogs resulting from surface illumination at 980 nm were measured. Following a lateral hemi-laminectomy, a flexible probe fabricated on a plastic tubular substrate of 6.325 mm diameter incorporating nine miniature photodetectors was embedded in the thoracic to lumbar segment of the spinal canal.
View Article and Find Full Text PDFWe correct one typographical error of three equations in Appl. Opt.56, 1447 (2017)APOPAI0003-693510.
View Article and Find Full Text PDFJ Biomed Opt
August 2018
Solid-organ transplant is one of the most complex areas of modern medicine involving surgery. There are challenging opportunities in solid-organ transplant, specifically regarding the deficiencies in pathology workflow or gaps in pathology support, which may await alleviations or even de novo solutions, by means of point-of-care, or point-of-procedure optical biomarkers. Focusing the discussions of pathology workflow on donor liver assessment, we analyze the undermet need for intraoperative, real-time, and nondestructive assessment of the donor injuries (such as fibrosis, steatosis, and necrosis) that are the most significant predictors of post-transplant viability.
View Article and Find Full Text PDFWe hypothesize that the capsular optical properties and thickness combined affect how accurate the diffuse reflectance on the surface of a capsular solid organ represents that on the subcapsular parenchyma. Monte Carlo simulations on two-layer geometries evaluated how a thin superficial layer with the thickness from 10 to 1000 μm affected the surface diffuse reflectance over a source-detector separation spanning 0.01 to 10 mm.
View Article and Find Full Text PDFNoninvasive photobiomodulation therapy (PBMT) of spinal cord disease remains speculative due to the lack of evidence for whether photobiomodulatory irradiances can be transcutaneously delivered to the spinal cord under a clinically acceptable PBMT surface irradiation protocol. We developed a flexible nine-channel photodetection probe for deployment within the spinal canal of a cadaver dog after hemilaminectomy to measure transcutaneously transmitted PBMT irradiance at nine sites over an eight-cm spinal canal length. The probe was built upon a 6.
View Article and Find Full Text PDFInadvertent injury to important anatomic structures is a significant risk in minimally invasive surgery (MIS) that potentially requires conversion to an open procedure, which results in increased morbidity and mortality. Surgeons operating minimal-invasively currently do not have an easy-to-use, real-time device to aid in intraoperative identification of important anatomic structures that underlie tissue planes. We demonstrate freehand diffuse optical spectroscopy (DOS) imaging for intraoperatively identifying major underlying veins and arteries.
View Article and Find Full Text PDFThis study explores percutaneous single-fiber spectroscopy (SfS) of rat livers undergoing fatty infiltration. Eight test rats were fed a methionine-choline-deficient (MCD) diet, and four control rats were fed a normal diet. Two test rats and one control rat were euthanized on days 12, 28, 49, and 77 following initiation of the diet, after percutaneous SfS of the liver under transabdominal ultrasound guidance.
View Article and Find Full Text PDFThis work analytically examines some dependences of the differential pathlength factor (DPF) for steady-state photon diffusion in a homogeneous medium on the shape, dimension, and absorption and reduced scattering coefficients of the medium. The medium geometries considered include a semi-infinite geometry, an infinite-length cylinder evaluated along the azimuthal direction, and a sphere. Steady-state photon fluence rate in the cylinder and sphere geometries is represented by a form involving the physical source, its image with respect to the associated extrapolated half-plane, and a radius-dependent term, leading to simplified formula for estimating the DPFs.
View Article and Find Full Text PDFJ Opt Soc Am A Opt Image Sci Vis
October 2014
Part VI analytically examines time-domain (TD) photon diffusion in a homogeneous medium enclosed by a "concave" circular cylindrical applicator or enclosing a "convex" circular cylindrical applicator, both geometries being infinite in the longitudinal dimension. The aim is to assess characteristics of TD photon diffusion, in response to a spatially and temporally impulsive source, versus the line-of-sight source-detector distance along the azimuthal or longitudinal direction on the concave or convex medium-applicator interface. By comparing to their counterparts evaluated along a straight line on a semi-infinite medium-applicator interface versus the same source-detector distance, the following patterns are indicated: (1) the peak photon fluence rate is always reached sooner in concave and later in convex geometry; (2) the peak photon fluence rate decreases slower along the azimuthal and faster along the longitudinal direction on the concave interface, and conversely on the convex interface; (3) the total photon fluence decreases slower along the azimuthal and faster along the longitudinal direction on the concave interface, and conversely on the convex interface; (4) the ratio between the peak photon fluence rate and the total fluence is always greater in concave geometry and smaller in convex geometry.
View Article and Find Full Text PDFA geometric-sensitivity-difference (GSD) based reconstruction method is demonstrated in fluorescence diffuse optical tomography (FDOT) for improving the depth-localization of objects. The GSD method optimizes the data-model fit based on paired-measurements between source-detector pairs sharing either the source or the detector channel, as comparing to conventional methods that optimize the data-model fit based on un-paired measurements of individual source-detector pairs. This in silico study is limited to continuous-wave and 2-dimension, for a circular-array outward-imaging geometry of which the native sensitivity of measurement varies strongly with respect to the depth of the object.
View Article and Find Full Text PDFBackground And Objectives: Intervertebral disc herniation is a common disease in chondrodystrophic dogs, and a similar neurologic condition also occurs in humans. Percutaneous laser disc ablation (PLDA) is a minimally invasive procedure used increasingly for prevention of disc herniation. Currently, PLDA is performed on thoracolumbar discs with the same laser energy applied regardless of the differing extent of degeneration among mineralized discs.
View Article and Find Full Text PDFWe demonstrate the feasibility of diffuse optical tomography (DOT) of the proximal pancreas by using optical applicator channels deployed longitudinally along the exterior surface of a duodenoscope. As the duodenum that nearly encircles the proximal pancreas forms a natural "C-loop" that is approximately three-quarters of a circle of 5-6 cm in diameter, a multichannel optical applicator attached to a duodenoscope has the potential to perform transduodenal DOT sampling of the bulk proximal pancreas wherein most cancers and many cystic lesions occur. The feasibility of transduodenal DOT is demonstrated on normal porcine pancreas tissues containing an introduced gelatinous inclusion of approximately 3 cm in diameter, by using nine source channels and six detector channels attached to a duodenoscope.
View Article and Find Full Text PDFPurpose: To propose an alternative method of thermoacoustic wave generation based on heating of magnetic nanoparticles (MNPs) using alternating magnetic field (AMF).
Methods: The feasibility of thermoacoustic wave generation from MNPs by applying a short-burst of AMF or a frequency-modulated AMF is theoretically analyzed. As the relaxation of MNPs is strongly dependent upon the amplitude and frequency of AMF, either an amplitude modulated, fixed frequency AMF (termed time-domain AMF) or a frequency modulated, constant amplitude AMF (termed frequency-domain AMF) will result in time-varying heat dissipation from MNPs, which has the potential to generate thermoacoustic waves.
J Opt Soc Am A Opt Image Sci Vis
April 2013
As Part V in our series, this paper examines steady-state fluorescence photon diffusion in a homogenous medium that contains a homogenous distribution of fluorophores, and is enclosed by a "concave" circular cylindrical applicator or is enclosing a "convex" circular cylindrical applicator, both geometries being infinite in the longitudinal dimension. The aim is to predict by analytics and examine with the finite-element method the changing characteristics of the fluorescence-wavelength photon-fluence rate and the ratio (sometimes called the Born ratio) of it versus the excitation-wavelength photon-fluence rate, with respect to the source-detector distance. The analysis is performed for a source and a detector located on the medium-applicator interface and aligned either azimuthally or longitudinally in both concave and convex geometries.
View Article and Find Full Text PDFPurpose: To improve object depth-localization for diffuse optical tomography (DOT) in a circular-array outward-imaging geometry that is subjected to strong sensitivity variation with respect to imaging depth.
Methods: The authors introduce an alternative DOT image reconstruction approach that optimizes the data-model fit based on the paired measurements corresponding to two pairs of source-detector that share either the source or the detector, in comparison to the conventional method that optimizes the data-model fit based on the unpaired measurements corresponding to individual pairs of source-detector. This alternative approach, namely, geometric-sensitivity-difference (GSD) method, effectively reduces the variation of the reconstruction sensitivity with respect to imaging depth.