98%
921
2 minutes
20
Background: Cone-beam computed tomography (CBCT) is a widely used imaging technique. In practical applications, reducing projection views can decrease radiation exposure and accelerate scanning speed, with potential benefits for stationary CT systems. However, ultra-sparse-view acquisition (e.g., ≤ 30 views) introduces severe streak artifacts that degrade image quality. This poses a critical challenge because it is difficult to differentiate artifacts from real structures.
Methods: We propose a sliding volume-based streak artifact reduction network (S-STAR Net) to remove artifacts while preserving structural details. Our method introduces three key technical innovations: (1) A sliding sampling sub-volume approach to process 3D sub-volumes, fully leveraging spatial context. (2) A difference enhancement (DE) loss to help separate artifacts from real structures. (3) Novel network includes volume-attention aided residual (VAR) blocks and Fourier transform convolution (FTC) blocks for multi-domain feature learning.
Results: Evaluated under 30 projection views, the method was tested on two datasets: a walnut dataset and the CQ500 head CT dataset. Quantitative metrics (PSNR/SSIM) and qualitative assessments (multi-planar visualization, residual error maps) demonstrate that S-STAR Net achieves superior performance in both artifacts suppression and detail preservation compared to existing approaches.
Conclusions: The proposed method effectively addresses streak artifacts and recovers subtle structures in ultra-sparse-view CBCT reconstruction. Its robustness suggests broad applicability for medical image denoising, artifact reduction, and 3D image enhancement tasks.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12403527 | PMC |
http://dx.doi.org/10.1186/s12880-025-01910-y | DOI Listing |
Interv Neuroradiol
September 2025
Department of Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
PurposeTo evaluate the potential of Photon-Counting Detector CT Angiography (PCD-CTA) for the assessment of carotid and subclavian artery stents compared to digital subtraction angiography (DSA) and Duplex ultrasound (DUS).MethodsThis study is a single-center, retrospective analysis of consecutive patients treated with a stent for high grade stenosis of the extra-cranial carotid and the subclavian artery between April 2023 and May 2024. Polyenergetic images (PE), iodine and virtual monoenergetic images were performed at different keV levels (40 and 80) and with two body vascular reconstruction kernels (Bv56 and 72) with and without iterative metal artifact reduction.
View Article and Find Full Text PDFACS Omega
September 2025
Department of Anthropology, Texas A&M University, College Station, Texas United States.
Following their defeat in the Texas Revolution of 1836, the Mexican Army disabled and buried cannons used in the defense of the Alamo. Rediscovered in 1852, 13 of these cannons have since journeyed through private collections and public exhibits before arriving at the Alamo. Among them is a bronze 4-pounder cannon, thought to have seen action during the battle itself.
View Article and Find Full Text PDFSmall Methods
September 2025
School of Physics and Optoelectronics, South China University of Technology, Wushan Road 381, Guangzhou, 510640, China.
Magnetic-field enhancement of the oxygen evolution reaction (OER) represents a promising route toward more efficient alkaline water electrolyzers, yet its origin remains debated due to overlapping effects of mass transport and reaction kinetics. Here, we present a general experimental strategy that employs strong forced convection to suppress uncontrolled transport arising from natural diffusion and magnetohydrodynamic (MHD) flows. Using polycrystalline Au electrodes, we show that this approach resolves subtle OER variations under controlled flow and field conditions.
View Article and Find Full Text PDFNeuroscience
September 2025
College of Electrical and Control Engineering, Xi'an University of Science and Technology, Xi'an 710054, China; Xi'an Key Laboratory of Electrical Equipment Condition Monitoring and Power Supply Security., Xi'an 710054, China.
Motor imagery (MI) based brain-computer interfaces (BCI) decode neural activity to generate command outputs. However, the limited number of distinguishable commands in traditional MI-BCI systems restricts practical applications. To overcome this limitation, we propose a multi-character classification framework based on Electroencephalography (EEG) signals.
View Article and Find Full Text PDFPhys Med Biol
September 2025
Engineering Physics, Tsinghua University, Liuqing Building, Haidian District, Beijing, China, Beijing, Beijing, 100084, CHINA.
Objective Low-dose interior tomography integrates low-dose CT (LDCT) with region-of-interest (ROI) imaging which finds wide application in radiation dose reduction and high-resolution imaging. However, the combined effects of noise and data truncation pose great challenges for accurate tomographic reconstruction. This study aims to develop a novel reconstruction framework that achieves high-quality ROI reconstruction and efficient extension of recoverable region to provide innovative solutions to address coupled ill-posed problems.
View Article and Find Full Text PDF