Article Abstract

Background: The safety and efficacy of pulsed field ablation for pulmonary vein and posterior wall isolation in atrial fibrillation ablation are well established; however, evidence regarding its use in extra-pulmonary vein areas remains limited. The aim of this study was to assess the feasibility and durability of pulsed field ablation for coronary sinus (CS) and left atrial appendage (LAA) isolation and mitral isthmus (MI) ablation.

Methods: We analyzed data from consecutive patients who underwent repeat atrial fibrillation ablation with pulsed field ablation between February and October 2024. MI ablation, CS isolation, and LAA isolation were attempted in all patients using the Farapulse (Boston Scientific) ablation system. Acute isolation was assessed after a 20-minute waiting period and an adenosine challenge, while chronic durability was evaluated during a repeat procedure for LAA closure at 3 months.

Results: A total of 236 patients (145, 61.4% male) were included in our analysis. Acute CS isolation was achieved in 147 (62.2%) patients for the CS and in all patients for the LAA. Acute MI block was obtained in all patients. After a 20-minute waiting time, the adenosine challenge revealed dormant conduction in 52 (26.4%) cases for the CS, in 4 (1.7%) for the LAA, and MI block regression in 35 (14.8%). All patients underwent remapping at the time of left atrial appendage occlusion, which showed CS and LAA isolation in only 3 (1.3%) and 10 (4.6%) patients, respectively, and MI block in 13 (5.5%) cases.

Conclusions: Pulsed field ablation is a feasible and acutely effective method for CS and LAA isolation and MI block; however, lesion durability remains a significant limitation.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCEP.125.014026DOI Listing

Publication Analysis

Top Keywords

pulsed field
20
field ablation
20
laa isolation
16
left atrial
12
atrial appendage
12
ablation
10
isolation
9
ablation coronary
8
coronary sinus
8
sinus left
8

Similar Publications

Beyond Fixed-Size Skyrmions in Nanodots: Switchable Multistability with Ferromagnetic Rings.

Nano Lett

September 2025

Depto. Polimeros y Materiales Avanzados: Fisica, Quimica y Tecnologia, Universidad del País Vasco, UPV/EHU, 20018 San Sebastian, Spain.

We demonstrate a novel approach to controlling and stabilizing magnetic skyrmions in ultrathin multilayer nanostructures through spatially engineered magnetostatic fields generated by ferromagnetic nanorings. Using analytical modeling and micromagnetic simulations, we show that the stray fields from a Co/Pd ferromagnetic ring with out-of-plane magnetic anisotropy significantly enhance the Néel-type skyrmion stability in an Ir/Co/Pt nanodot, even stabilizing the skyrmion in the absence of Dzyaloshinskii-Moriya interactions. We demonstrate precise control over the skyrmion size and stability.

View Article and Find Full Text PDF

Origin and mitigation of the imprint effect in hafnia-based ferroelectrics.

Nanoscale

September 2025

School of Materials Science and Engineering, Wuhan University of Technology, Wuhan 430070, People's Republic of China.

The potential of hafnia-based ferroelectric materials for Ferroelectric Random Access Memory (FeRAM) applications is limited by the imprint effect, which compromises readout reliability. Here, we systematically investigate the asymmetric imprint behavior in W/HfZrO/W ferroelectric capacitors, demonstrating that the imprint direction correlates directly with the ferroelectric polarization state. Notably, a pre-pulse of specific polarity can temporarily suppress the imprint effect.

View Article and Find Full Text PDF

Background: Charcot foot is a debilitating complication of peripheral neuropathy and is primarily associated with diabetes, leading to structural damage, ulceration, and osteomyelitis. Pulsed electromagnetic field (PEMF) therapy is a promising treatment modality for wound healing and bone metabolism.

Objective: To evaluate the efficacy of PEMF therapy in promoting bone growth and ulcer healing in patients with Charcot foot ulcers.

View Article and Find Full Text PDF

Background: Electronic nicotine delivery systems (ENDS) utilize "E-liquids" in order to generate "E-vapor", an inhalable aerosolized mixture containing nicotine and flavors. Flavored ENDS are very popular among teens who vape, however, the possible cardiac electrophysiological harm of inhalation exposure to flavored ENDS are not fully understood.

Objective: To test if inhalation exposure to flavoring carbonyls in e-liquids compromises mitochondrial integrity, increases oxidative stress, and leads to cardiac electrophysiological toxicity.

View Article and Find Full Text PDF

From Mazes to Automation: Modernizing Working Memory Research in Animal Models.

Behav Brain Res

September 2025

Department of Cognitive Sciences, Faculty of Psychology and Education, University of Tehran, Tehran, Iran; School of Cognitive Sciences, Institute for Research in Fundamental Sciences (IPM), Niavaran, Tehran, Iran.

Working memory (WM) is a core cognitive mechanism necessary for adaptive behavior. In the last few decades, scientists have studied WM using rodent models through traditional and time-consuming approaches, such as the Radial Arm Maze and the T-Maze. While these traditional tools have presented fundamental understanding, their dependence on manual operations restrains experimental precision and scalability.

View Article and Find Full Text PDF