Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: The suction of the eye lens cortex is an integral step of cataract surgery. Two conventional angles of cortex removal, including suction in the tangential or normal direction to the cortex surface, have different resulting stress and the risk of failure. However, there is no study about the effect of suction angle on the risk of zonules failure. So, this investigation aimed to evaluate the effect of suction direction on zonules' mechanical behavior using finite element modeling.

Setting: In-silico Study.

Design: 3D finite element model experimental study.

Methods: A 3D finite element model was developed, including nucleus covered by cortex and capsule. Similar to cataract surgery, a circular rapture was considered at the top of the capsule to apply suction pressure. Finally, Zonular fibers were modeled as a continuum body using 3D solid elements (C3D8R). A custom FORTRAN subroutine was implemented to enforce tension-only behavior, mimicking the physiological characteristics of the zonules, which are resistant to tensile but not compressive loads. This method allows for a realistic simulation of zonular mechanics during cortical aspiration.

Results: The suction processes in tangential and normal angles were simulated; The resulting relative displacements between the cortex and capsule, as a criterion of cortex separation, versus the resulting maximum zonule displacements, were recorded in each model. The cortex-capsule relative displacement versus maximum zonule displacement indicated a diagram slope of 0.09 for tangential applying pressure and 0.02 in the case of applying normal pressure.

Conclusion: The results illustrated that zonules were less tensile in a specific magnitude of cortex-capsule relative displacement under tangential applying pressure, which means eye zonules have a lower risk of failure until the separation of the lens cortex.

Download full-text PDF

Source
http://dx.doi.org/10.1097/j.jcrs.0000000000001767DOI Listing

Publication Analysis

Top Keywords

finite element
16
suction angle
8
zonular fibers
8
cortex
8
cortex removal
8
lens cortex
8
cataract surgery
8
tangential normal
8
risk failure
8
element model
8

Similar Publications

On the biomechanics of a novel L5-S1 posterior fixation system: A finite element study.

Proc Inst Mech Eng H

September 2025

IDMEC, Instituto Superior Técnico, Universidade de Lisboa, Lisbon, Portugal.

Low back pain is estimated to affect more than 70% of the population. Recently, interspinous posterior devices are gaining attention as a less invasive alternative to the traditional pedicle screw systems. However, since most of these devices are not suitable for the L5-S1 segment, the goals for this study are to design a tailored fixation system for the L5-S1 level and to study its effects on the degenerated spine.

View Article and Find Full Text PDF

Osteoporosis constitutes a significant global health concern, however the development of novel treatments is challenging due to the limited cost-effectiveness and ethical concerns inherent to placebo-controlled clinical trials. Computational approaches are emerging as alternatives for the development and assessment of biomedical interventions. The aim of this study was to evaluate the ability of an In Silico trial technology (BoneStrength) to predict hip fracture incidence by implementing a novel approach designed to reproduce the phenomenology of falls as reported in clinical data, and by testing its accuracy in three virtual cohorts characterised by different risk profiles.

View Article and Find Full Text PDF

The effect of automatic brake system on the response of the lower limbs based on active muscle force.

Comput Methods Biomech Biomed Engin

September 2025

College of Mechanical and Transportation Engineering, Hunan University, Changsha, China.

This article employs a finite element model integrated with the Hybrid III dummy to investigate how automatic braking and active muscle forces influence lower-limb injuries in frontal collisions. Prolonged braking can increase the tibial index, indicating more severe injury to the lower leg. Braking mitigated thigh injury at 50 km/h but exacerbated it at 40 km/h.

View Article and Find Full Text PDF

Multi-tissue regeneration remains a critical clinical challenge due to the lack of solutions that can replicate the hierarchical heterogeneity of such complex interfaces. While biofabrication approaches, such as extrusion-based, allow replicating robust, biomimetic, and layered designs, constructs are usually hindered by inadequate phase/layer integration, poor filler dispersion, and mismatched rheological and mechanical performances. This study introduces an ink engineering strategy as a solution for integrating natural-based nanocomposites in multi-tissue regenerative approaches.

View Article and Find Full Text PDF

This study provides valuable guidance for simplifying fabrication procedures and enhancing the structural integrity and safety of carbon fiber (CF) laminate transfemoral (TF) prosthetic sockets. While the high specific strength of CF laminate sockets offers advantages over conventional plastics, essential production data-their orientation-dependent strength and optimal cure conditions-are lacking, often requiring complex, costly cure cycles. This study investigated (i) the influence of fiber orientation on TF prosthetic CF socket strength via finite element analysis (FEA) during standing, and (ii) optimal single-step Vacuum-Bag-Only (VBO) cure conditions for prepreg in a low-cost conventional oven.

View Article and Find Full Text PDF