Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The single-crystal diamond (SCD), owing to its extreme physical and chemical properties, serves as an ideal substrate for quantum sensing and high-frequency devices. However, crystal anisotropy imposes significant challenges on fabricating high-quality micro-nano structures, directly impacting device performance. This work investigates the effects of femtosecond laser processing on the SCD under two distinct crystallographic orientations via single-pulse ablation. The results reveal that ablation craters along the <100> orientation exhibit an elliptical shape with the major axis parallel to the laser polarization, whereas those along the <110> orientation form near-circular craters with the major axis at a 45° angle to the polarization. The single-pulse ablation threshold of the SCD along <110> is 9.56 J/cm, representing a 7.8% decrease compared to 10.32 J/cm for <100>. The graphitization threshold shows a more pronounced reduction, dropping from 4.79 J/cm to 3.31 J/cm (31% decrease), accompanied by enhanced sp carbon order evidenced by the significantly intensified G-band in the Raman spectra. In addition, a phase transition layer of amorphous carbon at the nanoscale in the surface layer (thickness of ~40 nm) and a narrow lattice spacing of 0.36 nm are observed under TEM, corresponding to the interlayer (002) plane of graphite. These observations are attributed to the orientation-dependent energy deposition efficiency. Based on these findings, an optimized crystallographic orientation selection strategy for femtosecond laser processing is proposed to improve the quality of functional micro-nano structures in the SCD.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12348195PMC
http://dx.doi.org/10.3390/nano15151160DOI Listing

Publication Analysis

Top Keywords

femtosecond laser
12
laser processing
12
crystal anisotropy
8
single-crystal diamond
8
micro-nano structures
8
single-pulse ablation
8
major axis
8
influence crystal
4
anisotropy femtosecond
4
laser
4

Similar Publications

Purpose: To discuss the technique and outcome of what the authors called the "flap-in-flap" technique and report its safety as a procedure for correction of post-laser in situ keratomileusis (LASIK) myopic regression.

Methods: Seven eyes of 4 patients were included in this study. All patients had previously undergone LASIK for compound myopic astigmatism using the Moria M2 micro-keratome (Moria) 8 to 12 years prior to presentation.

View Article and Find Full Text PDF

Purpose: To report the refractive outcome of femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) in correcting moderate to high hyperopia. Intraoperative effective optical zone (EOZ), centration offset, and postoperative higher order aberrations (HOAs) were analyzed to better understand factors affecting postoperative outcomes.

Methods: This was a prospective, consecutive case series study of LIKE for correcting hyperopia in one department from 2018 to 2023.

View Article and Find Full Text PDF

Purpose: To investigate eye movement dynamics during excimer laser ablation, specifically femtosecond laser-assisted in situ keratomileusis (FS-LASIK), and compare movement patterns between the right eye (always operated on first) and the left eye (operated on second), analyzing direction, magnitude, and temporal changes.

Methods: A retrospective analysis was conducted on 92 eyes from 46 patients who underwent FS-LASIK with the SCHWIND AMARIS system (SCHWIND eye-tech-solutions). Eye-tracking data were collected to record horizontal and vertical directional movements; variability was assessed using standardized metrics.

View Article and Find Full Text PDF

Modern surgical strategies for keratoconus aim to both stabilize disease progression and correct induced refractive errors. Effectively and simultaneously achieving both goals remains a relevant challenge. This study presents a clinical case of femtosecond laser-assisted intrastromal keratoplasty with implantation of a biosynthetic complex, demonstrating the efficacy of this surgical approach in treating keratoconus.

View Article and Find Full Text PDF

We introduce a novel method using a kilohertz (kHz) amplified 800 nm laser for the first experimental confinement of microparticles within a single beam. This study demonstrates that high-energy kHz pulses can confine 1-μm-radius polystyrene beads in water within ∼26 μm. This approach utilizes the unique properties of high-energy pulsed lasers, distinct from continuous-wave and megahertz pulsed lasers traditionally used in optical trapping.

View Article and Find Full Text PDF