98%
921
2 minutes
20
The pseudo-random spread spectrum photon counting three-dimensional imaging community is able to acquire detailed time-correlated photon counting depth profiles by collecting a large amount of data about a scene and applying the matched filtering (MF) algorithm. However, it limits their ability to process, transmit, and store. To solve this problem, we report the structural time-correlated sparse representation depth reconstruction framework. First, the inversion model to reconstruct the time-correlated photon counting depth profile based on the l1-norm is derived. Second, the Hankel matrix sparsity basis is proposed based on the MF's cross-correlation mechanism. The simulation test results show that compared to the FFT and DCT basis, the proposed basis is sparser. Our main objective is to effectively compress the received photon stamps and exploit the signal sparsity in the correlation domain. In order to validate the proposed framework, extensive experiments on our laboratory system are implemented. The results demonstrate that only 10% of data is sufficient to reconstruct two depth peaks of the partially occluding object with the noise of 100 c/s. When background noise is 100 c/s, 4000 c/s, and 8000 c/s, using the depth estimated by the MF as the reference, the proposed method's imaging mean squared error is 0.3 cm, 1.4 cm, and 2.8 cm, respectively, only with 10%-30% of data. It consumes nearly one ten-thousandth of the energy of the MF method. The proposed framework is excellent in lightweight data process, high speed computation, and low power consumption.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.538642 | DOI Listing |
Radiol Phys Technol
September 2025
Department of Cardiovascular Internal Medicine, NHO Kagoshima Medical Center, 8-1, Shiroyamacho, Kagoshima, Kagoshima, 892-0853, Japan.
In Tl myocardial perfusion single-photon emission computed tomography (SPECT), gastric wall uptake can impact the inferior wall. This study aimed to evaluate the effectiveness and usefulness of the masking on un-smoothed image (MUS) method for Tl myocardial perfusion SPECT. A hemispherical gastric wall phantom was created to simulate the gastric fundus located closest to the myocardium, and the activity was enclosed to achieve an SPECT count ratio against the myocardium equivalent to that observed in clinical practice.
View Article and Find Full Text PDFAJNR Am J Neuroradiol
September 2025
From the Department of Otorhinolaryngology Head and Neck Surgery (J.G., Y.L., S.G.) and Department of Radiology (N.X., R.T., H.D.,Z.Y., Z.W., P.Z.), Beijing Friendship Hospital, Capital Medical University, Beijing, China.
Background And Purpose: Isolated congenital middle ear malformation contributes significantly to congenital hearing loss and growth problems. This study aims to compare 0.1 mm isotropic ultra-high-resolution computed tomography and conventional high-resolution computed tomography for assessing isolated congenital middle ear malformation, using surgical exploration as the gold standard.
View Article and Find Full Text PDFPLoS One
September 2025
Department of Medicine, Faculty of Medicine Siriraj Hospital, Mahidol University, Thailand.
In Thailand, sexually transmitted infections (STIs) persist as a significant public health issue, notwithstanding the affordability of treatments. The primary challenge lies in diagnostic methodologies. According to the Thai National Treatment Guidelines for abnormal vaginal discharge, wet preparation using proportion of white blood cell (WBC) counts and epithelial cell (EC) guides presumptive STI treatment.
View Article and Find Full Text PDFInterv Neuroradiol
September 2025
Department of Neuroradiology, University Hospital RWTH Aachen, Aachen, Germany.
PurposeTo evaluate the potential of Photon-Counting Detector CT Angiography (PCD-CTA) for the assessment of carotid and subclavian artery stents compared to digital subtraction angiography (DSA) and Duplex ultrasound (DUS).MethodsThis study is a single-center, retrospective analysis of consecutive patients treated with a stent for high grade stenosis of the extra-cranial carotid and the subclavian artery between April 2023 and May 2024. Polyenergetic images (PE), iodine and virtual monoenergetic images were performed at different keV levels (40 and 80) and with two body vascular reconstruction kernels (Bv56 and 72) with and without iterative metal artifact reduction.
View Article and Find Full Text PDFJ Biomed Mater Res B Appl Biomater
September 2025
Contipro a.s., Czech Republic.
Drug delivery to the central nervous system (CNS) is primarily hindered by the blood-brain barrier (BBB). To address this, mucoadhesive formulations have been designed to prolong residence time at the application site. In this study, we comprehensively characterized the physicochemical and mucoadhesive properties of hyaluronic acid tyramine (HATA) photocrosslinked hydrogels using rheological methods, nanoindentation, contact angle goniometry, and advanced confocal microscopy.
View Article and Find Full Text PDF