Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Most human physiological and motion information can be converted into surface vibration signals, which can be monitored through flexible wearable pressure sensors. However, the pressure levels generated by different physiological signals vary widely, ranging from a few Pa to several MPa. The current existing flexible pressure sensors struggle to simultaneously achieve such a wide detection range with high sensitivity. To address this challenge, a forward design method is proposed to realize the ultra-wide range and highly sensitive flexible pressure sensor simultaneous via the synergistic effects of the gradient porous structure, a multi-level pyramid array, and a composite piezoresistive material. The sensitivity is calculated to be 345.8 (0-1 MPa) and 3320.2kPa (1-2 MPa) after linear fitting. Impressively, the sensitivity increases with the increase of pressure, which is unusual as before. Additionally, the sensor exhibits a high resolution better than 1‰ across the full range, a fast response/recovery time (30/50 ms), and long-term operational stability. Significantly, the sensor demonstrates the non-saturating sensitivity characteristics, overcoming the bottleneck of saturation in flexible pressure sensors under high-pressure conditions, thereby enabling high-precision monitoring of physiological and motion signals across different pressure levels.

Download full-text PDF

Source
http://dx.doi.org/10.1002/adhm.202501798DOI Listing

Publication Analysis

Top Keywords

flexible pressure
16
pressure sensors
12
forward design
8
ultra-wide range
8
range highly
8
highly sensitive
8
sensitive flexible
8
pressure
8
pressure sensor
8
physiological motion
8

Similar Publications

Objectives: Cervical cancer is a serious threat to women's life and health and has a high mortality rate. Colposcopy is an important method for early clinical cervical cancer screening, but the traditional vaginal dilator has problems such as discomfort in use and cumbersome operation. For this reason, this study aims to design an intelligent vaginal dilatation system to automate colposcopy and enhance patient comfort.

View Article and Find Full Text PDF

Deep Learning-Assisted Organogel Pressure Sensor for Alphabet Recognition and Bio-Mechanical Motion Monitoring.

Nanomicro Lett

September 2025

Nanomaterials & System Lab, Major of Mechatronics Engineering, Faculty of Applied Energy System, Jeju National University, Jeju, 63243, Republic of Korea.

Wearable sensors integrated with deep learning techniques have the potential to revolutionize seamless human-machine interfaces for real-time health monitoring, clinical diagnosis, and robotic applications. Nevertheless, it remains a critical challenge to simultaneously achieve desirable mechanical and electrical performance along with biocompatibility, adhesion, self-healing, and environmental robustness with excellent sensing metrics. Herein, we report a multifunctional, anti-freezing, self-adhesive, and self-healable organogel pressure sensor composed of cobalt nanoparticle encapsulated nitrogen-doped carbon nanotubes (CoN CNT) embedded in a polyvinyl alcohol-gelatin (PVA/GLE) matrix.

View Article and Find Full Text PDF

Localized Gradient Conductivity Enabled Ultrasensitive Flexible Tactile Sensors with Ultrawide Linearity Range.

Adv Mater

September 2025

Key Laboratory of Low Dimensional Quantum Structures and Quantum Control of Ministry of Education, School of Physics and Electronics, Hunan Normal University, Changsha, 410081, China.

The high sensitivity and wide linearity are crucial for flexible tactile sensors in adapting to diverse application scenarios with high accuracy and reliability. However, conventional optimization strategies of constructing microstructures suffer from the mutual restriction between the high sensitivity and wide linearity. Herein, a novel design of localized gradient conductivity (LGC) with partly covered low-conductivity (low-σ) carbon/Polydimethylsiloxane layer on high-conductivity (high-σ) silver nanowires film upon the micro-dome structure is proposed.

View Article and Find Full Text PDF

Purpose Of Review: This opinion article from the EAU Endourology Section critically summarizes the existing evidence on flexible and navigable suction ureteral access sheaths (FANS) to determine if they represent a paradigm shift in managing kidney and ureteral stones with flexible ureteroscopy (FURS). This scoping review aims to synthesize recent findings on FANS efficacy, safety, and potential to overcome limitations of conventional ureteral access sheath (C-UAS) and other modalities.

Recent Findings: Current evidence demonstrates FANS significantly outperforms C-UAS.

View Article and Find Full Text PDF

Background: Chronic nonspecific low back pain (CNSLBP) is associated with thoracolumbar fascia (TLF) dysfunction. However, the structural effects of Gua Sha, a Traditional Chinese Medicine technique, remain unclear. This study aimed to explore the acute and short-term effects of Gua Sha therapy on TLF thickness, pain intensity, and related physiological parameters in patients with CNSLBP.

View Article and Find Full Text PDF