Article Abstract

Wearable cuffless blood pressure (BP) technology is emerging as a critical tool for monitoring hypertension, the leading risk factor of most cardiovascular diseases. However, current cuffless BP methods are not accurate enough for clinical use, because they mainly use single or dual modalities/features as inputs for estimation. To address this challenge, we propose multimodal McBP-Net, built with hybrid CNN-LSTM architecture combing two-layer convolution operations with four-layer LSTMs to capture both local signal features and temporal dependencies for continuous dynamic beat-to-beat BP estimation. The McBP-Net includes photoplethysmographic, electrocardiographic, impedanceplethysmographic (IPG), and skin temperature (ST) signals as inputs. Validated on 23 subjects undergoing cold pressor test to induce large BP variability, the McBP-Net achieves the mean absolute errors of 4.19 and 2.98 mmHg for systolic BP (SBP) and diastolic BP (DBP), respectively, which fall within the accuracy range required by the Grade A of IEEE standard. The integration of four multimodal signals improves performance by 16.20%, 37.37%, and 49.52% over three-, dual-, and single-modality approaches, respectively, with significant contributions from IPG and ST signals. Notably, ST shows a strong nonlinear relationship with BP with high mutual information of 0.9056 for SBP. Furthermore, McBP-Net achieves a reasonable balance between accuracy and computational efficiency, offering inference speed of 36.7% faster and reducing computational demands by 78% compared to transformer-based models tested. Importantly, it maintains robust performance, with only a 0.21 mmHg degradation in dynamic SBP estimation when trained on rest-stage data. McBP-Net demonstrates promising potential in medical-grade wearable cuffless dynamic BP measurements.

Download full-text PDF

Source
http://dx.doi.org/10.1109/JBHI.2025.3548771DOI Listing

Publication Analysis

Top Keywords

dynamic beat-to-beat
8
blood pressure
8
hybrid cnn-lstm
8
wearable cuffless
8
mcbp-net achieves
8
mcbp-net
5
dynamic
4
beat-to-beat measurements
4
measurements blood
4
pressure multimodal
4

Similar Publications

Background: Blood pressure (BP) is not steady. It varies over intervals from months to consecutive cardiac cycles and this variation contains meaningful information beyond mean BP. Variability over multiple clinic visits (VVV-BP) and during 24-hour ambulatory monitoring (ABPV) is positively related to risk of stroke and coronary artery disease and negatively associated with cognitive performance.

View Article and Find Full Text PDF

Phase Angle (PA), derived from bioelectrical impedance analysis, reflects cellular health and may indicate physiological resilience in ageing. We examined the relationship between PA and blood pressure (BP) recovery following an orthostatic challenge in 107 older adults attending a specialist falls clinic. Participants underwent active stand testing with continuous, beat-to-beat BP monitoring over 180 seconds.

View Article and Find Full Text PDF

Mitochondrial fission and fusion appear to be relatively infrequent in cardiac cells compared to other cell types; however, the proteins involved in these events are highly expressed in adult cardiomyocytes (ACM). Therefore, these proteins likely have additional non-canonical roles. We have previously shown that DRP1 not only participates in mitochondrial fission processes but also regulates mitochondrial bioenergetics in cardiac tissue.

View Article and Find Full Text PDF

Introduction: Controlled breathing is a hemodynamic maneuver known to influence both baroreflex and chemoreflex sensitivity. This study investigated the impact of respiratory-driven oscillations on the relationship between cerebral autoregulation and autonomic nervous system (ANS) activity.

Methods: Sixty-one volunteers (median age: 23 years) underwent noninvasive measurements of arterial blood pressure (ABP), cerebral blood velocity (CBv), end-tidal CO (EtCO), and respiratory rate during spontaneous breathing and during three 5-min sessions of controlled breathing at 6, 10, and 15 bpm.

View Article and Find Full Text PDF

Wearable cuffless blood pressure (BP) technology is emerging as a critical tool for monitoring hypertension, the leading risk factor of most cardiovascular diseases. However, current cuffless BP methods are not accurate enough for clinical use, because they mainly use single or dual modalities/features as inputs for estimation. To address this challenge, we propose multimodal McBP-Net, built with hybrid CNN-LSTM architecture combing two-layer convolution operations with four-layer LSTMs to capture both local signal features and temporal dependencies for continuous dynamic beat-to-beat BP estimation.

View Article and Find Full Text PDF