Pre-Exercise Ingestion of Hydrogen-Rich Cold Water Enhances Endurance Performance and Lactate Response in Heat.

Medicina (Kaunas)

Research Unit: "Sport Sciences, Health and Movement" (UR22JS01), Higher Institute of Sports and Physical Education of Kef, University of Jendouba, Kef 7100, Tunisia.

Published: June 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Hyperthermia significantly limits endurance performance in hot environments. To enhance heat loss and optimize athletic performance, pre-cooling interventions can be employed to accelerate body cooling. Therefore, the aim of this study was to evaluate the effects of an internal pre-cooling intervention combined with external pre-cooling or hydrogen-rich water on endurance performance in the heat. In a double-blind crossover with counterbalanced trials, all participants underwent a shuttle run test after 30 min under the following conditions: (1) hydrogen-rich cold water ingestion (HRCW); (2) cold water ingestion and external pre-cooling (IEPC); and (3) cold-water ingestion (control). Maximal aerobic speed (MAS), number of shuttle run repetitions, dehydration, temperature, heart rate (HR), rate of perceived exertion (RPE), blood lactate, and feeling scale (FS) were measured during the 20 m shuttle run test. Our results revealed a significant variation in dehydration, MAS, number of shuttle run repetitions, blood lactate, RPE, and FS ( = [0.001-0.036]); additionally, a significant group × time interaction was found for body temperature ( = 0.021). Post hoc tests revealed a significant change for MAS (HRCW: < 0.001), number of shuttle run repetitions (HRCW: < 0.001), dehydration (HRCW: = 0.009; IEPC: = 0.008), blood lactate (HRCW: < 0.001; IEPC: < 0.001), RPE (HRCW: = 0.05; IEPC: = 0.004), and FS (HRCW: = 0.05; IEPC: = 0.004), as well as a significant decrease in body temperature (IEPC: < 0.001; HRCW: = 0.028) compared to the control condition after the test. However, no significant differences were reported in HR among the different conditions. In conclusion, findings from this study suggest that ingesting hydrogen-rich cold water effectively mitigates the effects of heat stress, thereby improving endurance performance, enhancing mood, and reducing ratings of perceived exertion.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12300684PMC
http://dx.doi.org/10.3390/medicina61071173DOI Listing

Publication Analysis

Top Keywords

cold water
16
endurance performance
16
hydrogen-rich cold
12
number shuttle
12
shuttle repetitions
12
blood lactate
12
hrcw 0001
12
external pre-cooling
8
shuttle test
8
water ingestion
8

Similar Publications

Background: Seasonal variation in mortality results from a combination of environmental, biological, and social factors, with ambient temperature recognized as a key contributor. However, comprehensive assessments disentangling temperature effects from other seasonal influences across a broad range of mortality causes remain limited. This study aimed to quantify and compare the mortality burden attributable to ambient temperature and broader seasonal variation across major causes of death in Spain.

View Article and Find Full Text PDF

Swimming in cold water is intrinsically unsafe. One of the threats is a fall in deep-body temperature, which adversely affects all body systems and increases the risk of death. Wetsuits mitigate, but do not negate this threat.

View Article and Find Full Text PDF

On-site mercury analyser employing enclosed quartz cell cold vapour atomic absorption spectrometry and 3D printing techniques.

Talanta

September 2025

Department of Chemistry and Biotechnology, Faculty of Science and Technology, Kochi University, 2-5-1 Akebono-cho, Kochi City, Kochi, 780-8520, Japan. Electronic address:

The development of on-site Hg analysers is crucial for the rapid evaluation of Hg concentrations in environmental research. However, the fabrication of Hg analysers requires simplification of analytical procedures and device miniaturisation. Based on the above requirements, our research group previously investigated enclosed quartz cell cold vapour atomic absorption spectrometry (EQC-CV-AAS) as a base technique for an on-site Hg analyser.

View Article and Find Full Text PDF

Despite periods of permanent darkness and extensive ice coverage in polar environments, photosynthetic ice diatoms display a remarkable capability of living inside the ice matrix. How these organisms navigate such hostile conditions with limited light and extreme cold remains unknown. Using a custom subzero temperature microscope during an Arctic expedition, we present the finding of motility at record-low temperatures in a Eukaryotic cell.

View Article and Find Full Text PDF

Freezing point depression due to high salt concentration is crucial for liquid water to exist on cold worlds, expanding special regions where habitats are plausible. Determination of the growth tolerances of terrestrial microbes in analog systems impacts planetary protection protocols aimed at preventing interference with life detection missions or potential native ecosystems on celestial bodies. We measured the salinity tolerances of 18 salinotolerant bacteria (Bacillus, Halomonas, Marinococcus, Nesterenkonia, Planococcus, Salibacillus, and Terribacillus).

View Article and Find Full Text PDF