A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

An Inorganic/Organic Hybrid Phototransistor with Gate-Tunable Response and Broad-Spectrum Detection for Pulse Oximetry. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

High-performance, broad-spectrum detection spanning the visible to the near-infrared region is critical for applications such as image sensing, optical communications, and health monitoring. Although inorganic/organic hybrid phototransistors (HPTs) have been explored for such applications, a universal design strategy for material combinations and a thorough understanding of the gate-modulated photocurrent generation mechanism in these HPTs are still required. In this work, we demonstrate an inorganic/organic HPT by integrating a high-mobility, solution-processed amorphous metal oxide semiconductor with a photosensitive organic bulk heterojunction. Thanks to the rational type-II band alignment, this heterostructure efficiently decouples carrier generation and transport processes, thus introducing a photogating effect. By strategically gate-modulating the dominant photocurrent generation mechanism from photoconductive to photogating effects, the device achieves a maximum sensitivity of ∼10, specific detectivity of 1.5 × 10 Jones, and responsivity of 1.0 × 10 A W under 808 nm illumination. Furthermore, the HPT also exhibits a broadband photodetection capability as well as excellent operational stability in an ambient environment. These attributes make our HPT a sensitive detection unit for pulse oximetry sensing without requiring any external amplification circuits. The results of this study highlight the potential of this hybrid design approach for tailoring optoelectronic properties, thus offering a promising pathway for practical applications demanding weak signal detection across broad spectral ranges.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.5c09211DOI Listing

Publication Analysis

Top Keywords

inorganic/organic hybrid
8
broad-spectrum detection
8
pulse oximetry
8
photocurrent generation
8
generation mechanism
8
hybrid phototransistor
4
phototransistor gate-tunable
4
gate-tunable response
4
response broad-spectrum
4
detection
4

Similar Publications