Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The accurate prediction of blood glucose is critical for the effective management of diabetes. Modern continuous glucose monitoring (CGM) technology enables real-time acquisition of interstitial glucose concentrations, which can be calibrated against blood glucose measurements. However, a key challenge in the effective management of type 2 diabetes lies in forecasting critical events driven by glucose variability. While recent advances in deep learning enable modeling of temporal patterns in glucose fluctuations, most of the existing methods rely on unimodal inputs and fail to account for individual physiological differences that influence interstitial glucose dynamics. These limitations highlight the need for multimodal approaches that integrate additional personalized physiological information. One of the primary reasons for multimodal approaches not being widely studied in this field is the bottleneck associated with the availability of subjects' health records. In this paper, we propose a multimodal approach trained on sequences of CGM values and enriched with physiological context derived from health records of 40 individuals with type 2 diabetes. The CGM time series were processed using a stacked Convolutional Neural Network (CNN) and a Bidirectional Long Short-Term Memory (BiLSTM) network followed by an attention mechanism. The BiLSTM learned long-term temporal dependencies, while the CNN captured local sequential features. Physiological heterogeneity was incorporated through a separate pipeline of neural networks that processed baseline health records and was later fused with the CGM modeling stream. To validate our model, we utilized CGM values of 30 min sampled with a moving window of 5 min to predict the CGM values with a prediction horizon of (a) 15 min, (b) 30 min, and (c) 60 min. We achieved the multimodal architecture prediction results with Mean Absolute Point Error (MAPE) between 14 and 24 mg/dL, 19-22 mg/dL, 25-26 mg/dL in case of Menarini sensor and 6-11 mg/dL, 9-14 mg/dL, 12-18 mg/dL in case of Abbot sensor for 15, 30 and 60 min prediction horizon respectively. The results suggested that the proposed multimodal model achieved higher prediction accuracy compared to unimodal approaches; with upto 96.7% prediction accuracy; supporting its potential as a generalizable solution for interstitial glucose prediction and personalized management in the type 2 diabetes population.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12307872PMC
http://dx.doi.org/10.1038/s41598-025-07272-3DOI Listing

Publication Analysis

Top Keywords

interstitial glucose
16
type diabetes
16
health records
12
cgm values
12
glucose
9
deep learning
8
blood glucose
8
effective management
8
management type
8
multimodal approaches
8

Similar Publications

The human kidneys play a pivotal role in regulating blood pressure, water, and salt homeostasis, but assessment of renal function typically requires invasive methods. Deuterium metabolic imaging (DMI) is a novel, noninvasive technique for mapping tissue-specific uptake and metabolism of deuterium-labeled tracers. This study evaluates the feasibility of renal DMI at 7-Tesla (7T) to track deuterium-labeled tracers with high spatial and temporal resolution, aiming to establish a foundation for potential clinical applications in the noninvasive investigation of renal physiology and pathophysiology.

View Article and Find Full Text PDF

Wearable technologies that analyse non-conventional biological matrices, such as interstitial fluid, sweat, tears or breath, have the potential to provide longitudinal biomarker data with minimal invasiveness. These data could provide insights into physiological and behavioural patterns, in particular outside medical care facilities. Despite the success of continuous glucose monitoring, the adoption of wearable sensors for managing endocrine and metabolic diseases remains limited.

View Article and Find Full Text PDF

Aims: Calcific aortic valve disease is the most common valvular heart disease characterized by an inflammatory response in the leaflets followed by fibro-calcific remodelling of valvular interstitial cells (VICs). Lipoprotein(a) [Lp(a)] is a well-recognized risk factor for CAVD, however the role of metabolism in driving Lp(a)-induced inflammation remains largely elusive. Therefore, we aim to investigate the role of Lp(a) in driving inflammatory and metabolic changes in VICs and examine how alterations in cellular metabolism can alter their inflammatory phenotype.

View Article and Find Full Text PDF

A flexible microneedle sensor for long-term, enzyme-free glucose monitoring with high sensitivity and stability.

Anal Chim Acta

October 2025

Shanghai Frontier Science Research Center for Advanced Textiles, College of Textiles, Donghua University, Shanghai, 201620, China; Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China. Electronic address:

Background: Blood glucose monitoring is of paramount importance for patients with diabetes. However, conventional glucose meters exhibit limited accuracy and present challenges for prolonged use, primarily due to the high consumption of glucose oxidase (GOD) and their sensitivity to temperature and environmental factors. phenylboronic acid (PBA), benefiting from its reversible reaction with glucose and superior stability, holds potential as a promising medium for long-term glucose monitoring.

View Article and Find Full Text PDF

Sodium-glucose-cotransporter-2 inhibitors (SGLT2i) and statins are increasingly used for reduction of cardiovascular mortality in type 2 diabetics. Few case studies reported an enhanced risk of rhabdomyolysis with this combination. A 57-year-old man with normal renal functions, developed fatigue and oliguria within three days of dapagliflozin addition to his preexistent rosuvastatin therapy.

View Article and Find Full Text PDF