Article Abstract

Purpose: To assess the safety and efficacy of two SCOLI designs (Yang's I/II) for astigmatism correction in manual cataract surgery and define incision size-astigmatism relationships.

Methods: A total of 72 eyes from 64 cataract patients who accept manual cataract extraction surgery via a SCOLI technique. The two different types of incision: Yang's I and II incisions were applied in this study. The patients were divided into four groups based on corneal topography: Group 1 (0.25-1.5D), Group 2 (1.5-2.5D), Group 3 (2.5-3.5D), and Group 4 (>3.5D). In both groups, the incisions of different lengths were made on the steepest axis. 1 day, 1 week, 1 month, and 3 months after surgery, the postoperative corneal topography was examined, and the surgically induced astigmatism (SIA) was computed by an open-source software SIA calculator.

Result: Seventy-two eyes of 64 cataract patients were analyzed in this study. The difference in average K preoperative (44.29 ± 1.68) and 3 months postoperative (44.32 ± 1.71) was not statistically significant ( P = 0.529). The mean SIA at 3 months was 0.67 ± 0.16 D (Group 1), 1.54 ± 0.42D (Group 2), 2.04 ± 0.35D (Group 3), and 3.74 ± 1.83 D (Group 4). Statistically significant SIA changes were found among different groups (all P < 0.05). The SIA at 1 day was statistically significant compared to the SIA at 3 months ( P = 0.013). The DAP plots showed displacement of the centroid from the periphery toward the center in all groups.

Conclusion: SCOLI merges refractive precision with manual cataract extraction, offering a suture-free, adaptable solution for astigmatism correction (0.25-4.5 D). Its cost-effectiveness and safety profile make it particularly viable for resource-limited settings.

Download full-text PDF

Source
http://dx.doi.org/10.4103/IJO.IJO_2532_24DOI Listing

Publication Analysis

Top Keywords

manual cataract
16
astigmatism correction
12
cataract surgery
8
eyes cataract
8
cataract patients
8
cataract extraction
8
corneal topography
8
group
8
sia months
8
cataract
6

Similar Publications

Predictors of Selective Laser Trabeculoplasty Efficacy Results from the Swedish Optimal SLT Multicenter Randomized Controlled Trial.

Ophthalmol Glaucoma

September 2025

Department of Clinical Neuroscience, Institute of Neuroscience and Physiology, Sahlgrenska Academy, University of Gothenburg, Sweden; Department of Ophthalmology, Sahlgrenska University Hospital, Region Västra Götaland, Mölndal, Sweden.

Purpose: To investigate the impact of potential predictor variables on selective laser trabeculoplasty (SLT) efficacy in the Swedish Optimal SLT (OSLT) trial.

Design: Post hoc analysis of a multicenter, masked, randomized controlled trial.

Subjects: 512 eyes from 399 patients enrolled in the OSLT trial.

View Article and Find Full Text PDF

Purpose: This study aimed to revise data published in the literature on the effects of cataract surgery on tear film characteristics, in relation to personal clinical surgical experience.

Methods: A search was undertaken using PubMed (all years). Search terms included 'cataract surgery', 'phacoemulsification', 'cataract extraction', and 'manual small-incision cataract surgery', combined at first with 'ocular surface' and 'lacrimal film'.

View Article and Find Full Text PDF

Cataract surgery is still the most common surgery performed worldwide. It has evolved tremendously in terms of incision, from 12 mm to 1.8 mm, in terms of capsulotomy from envelope type to automated capsulorhexis, and from rigid intraocular lens to foldable intraocular lenses.

View Article and Find Full Text PDF

Digital marking versus manual marking technique for toric intraocular lens alignment: a meta-analysis.

BMC Ophthalmol

September 2025

Department of Ophthalmology, Tongji Medical College, The Central Hospital of Wuhan, Huazhong University of Science and Technology, No 26 Shengli Street, Wuhan, 430014, China.

Background: Manual and digital-assisted marking are the two main marking methods used for toric intraocular lens (IOL) in cataract surgery. However, there is a lack of consensus regarding the consistency in accuracy for these two methods. This meta-analysis aimed to compare and evaluate the accuracy of digital and manual marking techniques for toric IOL alignment during cataract surgery.

View Article and Find Full Text PDF

This study aimed to evaluate whether clear corneal incisions (CCIs) created with the FEMTO LDV Z8 femtosecond laser during cataract surgery are non-inferior to manual CCIs in terms of surgically induced astigmatism (SIA) and higher-order aberrations (HOAs). A total of 78 cataract patients were randomly assigned to two groups: 38 eyes underwent femtosecond laser-assisted cataract surgery (FLACS), and 40 eyes underwent conventional manual cataract surgery (CCS). Preoperative and six-week postoperative SIA, HOAs, and all topographic and refractive data were analysed for both groups.

View Article and Find Full Text PDF