On-Mask Magnetoelastic Sensor Network for Self-Powered Respiratory Monitoring.

ACS Nano

Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095, United States.

Published: July 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Respiratory monitoring is crucial because it provides key insights into a person's health and physiological conditions. Conventional respiratory sensing is significantly challenged by the presence of water vapor in exhaled breath. An on-mask magnetoelastic sensor network is developed, featuring an ultralight, intrinsically waterproof architecture to achieve continuous, long-term respiratory monitoring and real-time, high-fidelity signal acquisition. Leveraging the giant magnetoelastic effect, each soft magnetoelastic sensor is miniaturized to only 3.2 g, which markedly enhances its sensitivity to airflow-induced mechanical fluctuations during respiration while also ensuring sufficient wearing comfort for daily use. Beyond mechanical compliance, the system achieves a signal-to-noise ratio exceeding 35 dB and a rapid response time of 80 ms under the optimal conditions, and it can reliably transduce the fluid dynamics generated during respiration in the mouth-mask microenvironment into high-fidelity electrical signals for continuous respiratory monitoring. With the aid of machine learning, the on-mask magnetoelastic sensor network achieves respiration pattern recognition with a classification accuracy of up to 94.03%. Furthermore, a user-friendly, custom-designed mobile application has been developed to process respiratory signals, enabling real-time, data-driven diagnosis and one-click health data sharing with clinicians. This machine-learning-enhanced magnetoelastic sensor network is expected to support personalized respiratory management in the Internet of Things era.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsnano.5c07614DOI Listing

Publication Analysis

Top Keywords

magnetoelastic sensor
20
sensor network
16
respiratory monitoring
16
on-mask magnetoelastic
12
respiratory
7
sensor
5
magnetoelastic
5
network
4
network self-powered
4
self-powered respiratory
4

Similar Publications

On-Mask Magnetoelastic Sensor Network for Self-Powered Respiratory Monitoring.

ACS Nano

July 2025

Department of Bioengineering, University of California, Los Angeles, Los Angeles, California 90095, United States.

Respiratory monitoring is crucial because it provides key insights into a person's health and physiological conditions. Conventional respiratory sensing is significantly challenged by the presence of water vapor in exhaled breath. An on-mask magnetoelastic sensor network is developed, featuring an ultralight, intrinsically waterproof architecture to achieve continuous, long-term respiratory monitoring and real-time, high-fidelity signal acquisition.

View Article and Find Full Text PDF

This study explores the impact of thermal annealing on the magnetic signal enhancement of three distinct Metglas ribbon materials: 2826MB3, 2605SA1, and 2714A. Each material underwent a systematic annealing process under a range of temperatures (50-500 °C) and durations (10-60 min) to evaluate the influence of thermal treatment on their magnetic signal response. The experimental setup applied a constant excitation frequency of 20 kHz, allowing for direct comparison under identical measurement conditions.

View Article and Find Full Text PDF

Two different magnetoelastic Metglas materials with distinct shapes were compared as sensing elements for the structural health monitoring of concrete beams. One had a ribbon shape, while the other had a microwire shape. The sensing elements were attached to different concrete beams, and a crack was introduced into each beam.

View Article and Find Full Text PDF

A Programmable Hybrid Energy Harvester: Leveraging Buckling and Magnetic Multistability.

Micromachines (Basel)

March 2025

Department of Mechanical Engineering & Mecha(tro)nic System Dynamics (LMSD), KU Leuven, 9000 Gent, Belgium.

Growing demands for self-powered, low-maintenance devices-especially in sensor networks, wearables, and the Internet of Things-have intensified interest in capturing ultra-low-frequency ambient vibrations. This paper introduces a hybrid energy harvester that combines elastic buckling with magnetically induced forces, enabling programmable transitions among monostable, bistable, and multistable regimes. By tuning three key parameters-buckling amplitude, magnet spacing, and polarity offset-the system's potential energy landscape can be selectively shaped, allowing the depth and number of potential wells to be tailored for enhanced vibrational response and broadened operating bandwidths.

View Article and Find Full Text PDF

An Amplitude Analysis-Based Magnetoelastic Biosensing Method for Quantifying Blood Coagulation.

Biosensors (Basel)

March 2025

Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing 400044, China.

Blood coagulation tests are crucial in the clinical management of cardiovascular diseases and preoperative diagnostics. However, the widespread adoption of existing detection devices, such as thromboelastography (TEG) instruments, is hindered by their bulky size, prohibitive cost, and lengthy detection times. In contrast, magnetoelastic sensors, known for their low cost and rapid response, have garnered attention for their potential application in various coagulation tests.

View Article and Find Full Text PDF