98%
921
2 minutes
20
In order to study the mechanical properties of seven-wire steel strands after wire breakage failure, this study is based on the established finite-element beam-element model of seven-wire steel strands and analyzes two failure forms of symmetric wire breakage and asymmetric wire breakage. The stress redistribution pattern, recovery length, and parameter influences (temperature: 0-40 °C; friction coefficient: 0.15-0.30; torsion angle: 4-7°) are analyzed. The results show that broken wire damage will cause the stress of the intact steel wire to increase rapidly, increasing the risk of fracture of the intact steel wire. The recovery length will shorten with the increase in the friction coefficient, torsion angle, and the number of broken wires but will extend with the increase in temperature. The stress changes in the steel strand are as follows: when the number of broken wires increases, the maximum stress increases significantly and the average stress decreases slightly; when the temperature rises, the maximum stress and average stress in both cases of wire breakage show a significant linear decrease. These research results provide important references for the safety assessment and life prediction of cables in bridge engineering.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12251424 | PMC |
http://dx.doi.org/10.3390/ma18133148 | DOI Listing |
Front Vet Sci
August 2025
Department of Veterinary Surgery, Graduate School of Veterinary Medicine, Konkuk University, Seoul, Republic of Korea.
Introduction: The conventional pin and tension band wiring (TBW) technique remains the standard for fixation, but is frequently associated with complications such as wire breakage, loosening, and delayed healing in patellar fracture. Locking plate fixation has demonstrated superior biomechanical stability in human studies. This study aimed to compare the biomechanical performance of locking plate fixation versus TBW in canine transverse patellar fractures and to evaluate the influence of plate design on fixation strength.
View Article and Find Full Text PDFJACC Case Rep
August 2025
King Abdulaziz Cardiac Center, National Guard Hospital, Riyadh, Saudi Arabia.
Objective: To describe a novel balloon-assisted intraluminal technique for the removal of a kinked catheter during transradial coronary angiography complicated by subclavian artery tortuosity.
Key Steps: Catheter kinking was recognized during transradial access, refractory to standard maneuvers. A retrieval attempt with snare via femoral access failed.
Cureus
July 2025
Spinal Surgery, Kameda Medical Center, Chiba, JPN.
Perioperative complications in spinal surgery include dural injury, postoperative epidural hematoma, and surgical site infections. More severe complications involve paralysis, sensory deficits due to nerve injury, and bladder or bowel dysfunction. During fusion surgery, attention must also be paid to risks such as guide wire breakage, cage migration or dislodgement, and major vascular injury during intervertebral disc gauge placement.
View Article and Find Full Text PDFJ Orthop Surg Res
July 2025
Department of Orthopaedics and Traumatology, Trakya University School of Medicine, Edirne, 22030, Türkiye.
Background: The aim of this study was to identify the radiographic parameters associated with failure of tension band wiring (TBW) in the treatment of transverse patellar fractures, with the goal of guiding surgical decision-making.
Materials And Methods: A total of 76 patients underwent surgical treatment for patellar fractures at Trakya University between January 2013 and December 2022. We retrospectively analyzed 32 patients who met the study's inclusion criteria for transverse fractures (AO Type 34- C1) treated with TBW.
Materials (Basel)
July 2025
Sanya Science and Education Innovation Park, Wuhan University of Technology, Sanya 572000, China.
In order to study the mechanical properties of seven-wire steel strands after wire breakage failure, this study is based on the established finite-element beam-element model of seven-wire steel strands and analyzes two failure forms of symmetric wire breakage and asymmetric wire breakage. The stress redistribution pattern, recovery length, and parameter influences (temperature: 0-40 °C; friction coefficient: 0.15-0.
View Article and Find Full Text PDF