The size of parapelvic cyst may affect the effect of ureteroscopic laser incision and internal drainage.

Int Urol Nephrol

Department of Urology, Institute of Urology, West China Hospital, Sichuan University, No. 37 Guo Xue Xiang, Chengdu, 610041, Sichuan, People's Republic of China.

Published: July 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: To evaluate the efficacy and the safety of flexible ureteroscopic laser incision and internal drainage in the treatment of parapelvic cysts and investigate the key variables affecting the collapse effect after cyst surgery.

Methods: A retrospective analysis was conducted on the clinical data of 45 patients diagnosed with parapelvic cysts and treated with laser incision and internal drainage at West China Hospital of Sichuan University from January 2018 to December 2024. The reduction ratio of the maximum transverse diameter of the cysts pre- and post-operation was utilized as the criterion for assessing therapeutic efficacy. Scatter plots illustrating the postoperative reduction ratio and the preoperative maximum transverse diameter of the cysts, along with the receiver operating characteristic (ROC) curve, were constructed. The postoperative collapse of the cysts and the reduction ratio of their maximum transverse diameter were statistically described. Univariate and multivariate logistic regression analyses were employed to identify the variables affecting the efficacy of incision and internal drainage in cysts post-operation.

Results: A cohort of 45 patients was monitored over a median duration of 12 months. These patients were categorized into two groups based on a postoperative reduction threshold of 50%: 9 patients were classified into the ineffective operation group, while 36 patients were classified into the successful operation group. At the 3-month follow-up, the success rate was determined to be 80%, with no cases of recurrence at 12 months. Univariate and multivariate analyses identified the maximum transverse diameter of the preoperative cyst as an independent predictor of surgical success (OR = 9.41, 95% CI 1.33-66.83, P = 0.025). Further regression analysis indicated that when the preoperative cyst's maximum transverse diameter exceeded 6 cm, the reduction ratio of the cyst's transverse diameter progressively decreased following internal drainage. Sensitivity, specificity, and area under the curve (AUC) of the ROC curve cutoff point were 77.8%, 72.2%, and 0.75, respectively.

Conclusion: The maximum transverse diameter of the cyst prior to surgery may serve as an independent factor influencing the efficacy of laser incision and internal drainage treatment for parapelvic cysts. This factor exhibits a negative correlation with the postoperative success rate. Specifically, when the cyst's diameter exceeds 6 cm, the likelihood of cyst collapse diminishes progressively.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11255-025-04649-1DOI Listing

Publication Analysis

Top Keywords

transverse diameter
28
internal drainage
24
maximum transverse
24
incision internal
20
laser incision
16
reduction ratio
16
parapelvic cysts
12
ureteroscopic laser
8
drainage treatment
8
treatment parapelvic
8

Similar Publications

Objective: Reveal the changing rule of the positional relationship between the uncinate process of cervical spine and vertebral artery by measuring the relevant parameters between the uncinate process of cervical spine and vertebral artery in different age groups.

Methods: A retrospective study was conducted on 1240 cases of cervical spine imaging data from 2018 to 2021 in the Radiology Department of the Affiliated Hospital of Inner Mongolia Medical University. The distance between the uncinate process superior ridge and vertebral artery and the maximum of pedicle transverse angle, the minimum of pedicle transverse angle, the range of pedicle transverse angle and the pedicle width were measured according to age groups.

View Article and Find Full Text PDF

Computer-assisted surgery and planning in percutaneous pelvic screw fixation.

Orthop Traumatol Surg Res

September 2025

CHU de Grenoble-Alpes, Université de Grenoble-Alpes, Laboratoire TIMC-IMAG, Unité de Chirurgie Orthopédique et Traumatologique, CNRS UMR 5525, Boulevard de la Chantourne, 38700 La Tronche, France.

Percutaneous pelvic screwing (PPS) enables fixation of traumatic or atraumatic fractures with little or no displacement, or displaced but reduced fractures, and preventive fixation of primary or secondary tumoral lesions. It is a relatively recent technique, and indications are evolving with progress in pre- and intra-operative imaging. Morbidity is lower than with open surgery.

View Article and Find Full Text PDF

Background And Aims: Endoscopic resection for submucosal tumors (SMTs) in the esophagus and cardia is challenging with hazards of adverse events and the exploration of its achieving textbook outcome (TO) was unknown. We aim to investigate the predictors of TO for giant SMTs with a long diameter ≥ 7 cm or a transverse diameter ≥ 3.5 cm.

View Article and Find Full Text PDF

Purpose: Presenting a technique to quantify the transverse relaxation time T, which is associated with the diffusion of water molecules through the internal magnetic field gradients of the lung in-vivo.

Methods: A Half-Fourier-Acquired Single-shot Turbo spin-Echo (HASTE) pulse sequence with Hahn-echo preparation was implemented and used for image acquisition. Quantification of T was performed by acquiring multiple images with identical TE, but with a different number of refocusing pulses between excitation and signal acquisition.

View Article and Find Full Text PDF

One-dimensional photonic crystal (1D-PhC) pillar cavities allow transducing mechanical pillar vibrations to the optical domain, thereby relaxing the requirements typically associated with mechanical motion detection. In this study, we integrate these geometries into a silicon-on-insulator photonics platform and explore their optical and mechanical properties. The 1D-PhC structures consist of a linear array of high aspect ratio nanopillars with nanometer-sized diameters, designed to enhance the interaction between transverse-magnetic (TM) polarized optical fields and mechanical vibrations and to minimize optical leaking to the substrate.

View Article and Find Full Text PDF