Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: Presenting a technique to quantify the transverse relaxation time T, which is associated with the diffusion of water molecules through the internal magnetic field gradients of the lung in-vivo.

Methods: A Half-Fourier-Acquired Single-shot Turbo spin-Echo (HASTE) pulse sequence with Hahn-echo preparation was implemented and used for image acquisition. Quantification of T was performed by acquiring multiple images with identical TE, but with a different number of refocusing pulses between excitation and signal acquisition. T was quantified on a voxel-by-voxel basis from the signal attenuation in the different acquisitions. Phantom experiments were performed to evaluate the ability of the proposed technique to discriminate signals with different T. Six samples containing a mixture of water and glass microspheres of different nominal diameters were used. The dependence of T on the sphere diameter was compared with that obtained from the conventional Hahn-echo experiment. In-vivo experiments were performed to investigate the dependence of T on both lung inflation and perfusion. For this, data were acquired in eleven healthy volunteers in different breathing states and different cardiac phases.

Results: Phantom experiments showed a monotonic increase of T with the sphere diameter in agreement with the results of the Hahn-echo experiment, demonstrating an excellent discrimination between signals with different T. In-vivo experiments showed a rather homogeneous distribution of T throughout the lung with a slight dependence on inflation. Mean values obtained in the diastolic cardiac phase resulted in 29 ms at Functional Residual Capacity (FRC) and in 24 ms at Total Lung Capacity (TLC). In the systolic phase the mean value at FRC was 14 ms, indicating a strong dependence of T on perfusion.

Conclusion: The proposed technique allows to quantify T of the lung in a single breath-hold of approximately 10s duration and could help in detecting functional and microstructural injuries of the lung.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.mri.2025.110514DOI Listing

Publication Analysis

Top Keywords

transverse relaxation
8
phantom experiments
8
experiments performed
8
proposed technique
8
sphere diameter
8
hahn-echo experiment
8
in-vivo experiments
8
lung
7
relaxation enhancement
4
enhancement h-mri
4

Similar Publications

Purpose: Presenting a technique to quantify the transverse relaxation time T, which is associated with the diffusion of water molecules through the internal magnetic field gradients of the lung in-vivo.

Methods: A Half-Fourier-Acquired Single-shot Turbo spin-Echo (HASTE) pulse sequence with Hahn-echo preparation was implemented and used for image acquisition. Quantification of T was performed by acquiring multiple images with identical TE, but with a different number of refocusing pulses between excitation and signal acquisition.

View Article and Find Full Text PDF

Distortions in the local symmetry around Ln(III) ions in SMMs significantly impacts slow magnetic relaxation by introducing transverse crystal field parameters that enhance quantum tunnelling of the magnetisation (QTM). Minimising these distortions, often using macrocyclic or sterically hindered ligands, or by tuning intermolecular interactions, is essential for suppressing QTM. A less-explored strategy involves aligning the molecular symmetry elements within the crystal lattice to generate a high-symmetry crystal lattice with symmetry enforced bond angles and lengths.

View Article and Find Full Text PDF

One-dimensional photonic crystal (1D-PhC) pillar cavities allow transducing mechanical pillar vibrations to the optical domain, thereby relaxing the requirements typically associated with mechanical motion detection. In this study, we integrate these geometries into a silicon-on-insulator photonics platform and explore their optical and mechanical properties. The 1D-PhC structures consist of a linear array of high aspect ratio nanopillars with nanometer-sized diameters, designed to enhance the interaction between transverse-magnetic (TM) polarized optical fields and mechanical vibrations and to minimize optical leaking to the substrate.

View Article and Find Full Text PDF

Background: Walking in minimalistic footwear (MF) increases mechanical loading on the knee joint, exposing it to acute stresses that may heighten the risk of early onset of knee osteoarthritis. This type of footwear can modify walking patterns in the lower limbs, further intensifying joint stress and contributing to the deterioration of articular surfaces.

Purpose: First, to evaluate the differences in kinetic variables associated with the early onset of knee osteoarthritis between MF and neutral footwear (NF) during walking; second, to determine the extent of acute cartilage loading in the knee joint, particularly footwear after 45 minutes of walking in an urban environment, using magnetic resonance imaging (T2 relaxation times [T2RTs] and percentage change of loading) in weightbearing zones.

View Article and Find Full Text PDF

Movable Oil Saturation Quantitation Evaluation in Shale Oil: Novel Insights from Distribution.

ACS Omega

August 2025

State Key Laboratory of Shale Oil and Gas Enrichment Mechanisms and Efficient Development, SINOPEC, Beijing 102206, China.

The quantification of movable shale oil is crucial for the effective exploration and development of shale oil resources. Nuclear magnetic resonance (NMR), a nondestructive and noninvasive technique, has become an indispensable tool for evaluating movable oil saturation. However, the small core sizes, high-frequency instrumentation, costly measurements, and significant losses of light hydrocarbons pose substantial challenges in accurately assessing movable oil.

View Article and Find Full Text PDF