Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsnano.5c07799DOI Listing

Publication Analysis

Top Keywords

correction "deep
4
"deep learning
4
learning enhanced
4
enhanced infrared-ii
4
infrared-ii imaging
4
imaging image-guided
4
image-guided small
4
small interfering
4
interfering ribonucleic
4
ribonucleic acid
4

Similar Publications

Background: Surgical site infection (SSI) after surgery can cause serious sequelae in patients with tibial plateau fractures. This study aims to report the incidence and characteristics of SSI and to investigate the risk factors of SSI in adult patients with closed tibial plateau fracture, especially the relationship between SSI and preoperative hypoalbuminemia.

Methods: We retrospectively reviewed the records of adult patients with closed tibial plateau fracture who were treated at our institution from January 2016 to December 2022.

View Article and Find Full Text PDF

Purpose: Recent developments in computational pathology have been driven by advances in vision foundation models (VFMs), particularly the Segment Anything Model (SAM). This model facilitates nuclei segmentation through two primary methods: prompt-based zero-shot segmentation and the use of cell-specific SAM models for direct segmentation. These approaches enable effective segmentation across a range of nuclei and cells.

View Article and Find Full Text PDF

Cardiovascular magnetic resonance imaging: Principles and advanced techniques.

Prog Nucl Magn Reson Spectrosc

September 2025

School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom; School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile; Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile; Institute for Biological and Medical

Cardiovascular magnetic resonance (CMR) imaging is an established non-invasive tool for the assessment of cardiovascular diseases, which are the leading cause of death globally. CMR provides dynamic and static multi-contrast and multi-parametric images, including cine for functional evaluation, contrast-enhanced imaging and parametric mapping for tissue characterization, and MR angiography for the assessment of the aortic, coronary and pulmonary circulation. However, clinical CMR imaging sequences still have some limitations such as the requirement for multiple breath-holds, incomplete spatial coverage, complex planning and acquisition, low scan efficiency and long scan times.

View Article and Find Full Text PDF

Reconstructing time-domain data from discontinuous Percept PC and RC output using external data acquisition and linear filtering.

J Neurosci Methods

September 2025

Center for Neurological Restoration, Neurological Institute, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH 44195, United States of America.

Background: The Medtronic Percept PC and RC are deep brain stimulation (DBS) systems with recording capability. However, when the stimulation frequency is changed, the recordings were segmented, introducing interruptions that shift each segment in the time domain.

New Method: Ex-vivo, stimulation frequency was changed while local field potential was being recorded in both leads.

View Article and Find Full Text PDF