The accuracy of VRF intraocular lens power calculation formula in cataract patients after radial keratotomy.

Int Ophthalmol

Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China.

Published: July 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To investigate the accuracy of the VRF intraocular lens (IOL) power calculation formula in cataract patients after radial keratotomy (RK).

Methods: This was a retrospective study that reviewed and retrieved the medical history of patients after RK who underwent cataract surgery from April 1, 2021, to December 31, 2024, at Beijing Tongren Hospital. A total of 50 eyes of 27 patients were included. The absolute error (AE, the absolute value of the difference between the actual Spherical Equivalent after cataract surgery and the Equivalent Spherical predicted by the IOL formulas) and the percentage of eyes with AE within 0.5D, 0.75D, 1.0D, and 2.0D were calculated by using three formulas: the VRF formula, the Kane formula and the Barrett True-K No History formula and were compared.

Results: There was a significant difference in AE values between the three formulas (X = 33.556, p < 0.001), with the VRF formula having the smallest median AE value (MedAE) of 0.580D, followed by the Kane formula (0.585D), and the Barrett True-K No History formula (0.670D) the largest. Using the VRF formula, the percentages of eyes with AE within 0.5D, 0.75D, 1.0D, and 2.0D were 48%, 66%, 78%, and 94%, respectively, which were equal to or higher than the other two formulas.

Conclusion: For this cohort of patients with cataract after RK, the VRF formula was the most accurate, and the Kane formula also demonstrated good accuracy. Both formulas can be tried to be applied to predict IOL power in patients with cataract after RK in future clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10792-025-03645-9DOI Listing

Publication Analysis

Top Keywords

accuracy vrf
8
vrf intraocular
8
intraocular lens
8
power calculation
8
calculation formula
8
formula cataract
8
cataract patients
8
patients radial
8
radial keratotomy
8
cataract surgery
8

Similar Publications

The aim of this study was to using purified chicken antibody (IgY) for developing solid phase competitive (SPC) enzyme-linked immunosorbent assay (ELISA) to detect the foot-and-mouth disease virus (FMDV) A serotype. After immunization of chickens, polyclonal immunoglobulin (IgY) antibodies were extracted and purified from egg yolk and yield was about 5.00 mg mL of yolk as well as near 0.

View Article and Find Full Text PDF

The accuracy of VRF intraocular lens power calculation formula in cataract patients after radial keratotomy.

Int Ophthalmol

July 2025

Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China.

Purpose: To investigate the accuracy of the VRF intraocular lens (IOL) power calculation formula in cataract patients after radial keratotomy (RK).

Methods: This was a retrospective study that reviewed and retrieved the medical history of patients after RK who underwent cataract surgery from April 1, 2021, to December 31, 2024, at Beijing Tongren Hospital. A total of 50 eyes of 27 patients were included.

View Article and Find Full Text PDF

Introduction: Vertical root fractures (VRFs) detection in cone-beam computed tomography (CBCT) images can be challenging when gutta-percha artifacts are present. This study aimed to evaluate how anteroposterior and laterolateral head angulations (APHA and LLHA, respectively), as well as tooth position (anterior or posterior region), influence the diagnostic accuracy of VRFs detection in CBCT for endodontically treated teeth.

Methods: Twenty single-rooted teeth were endodontically treated.

View Article and Find Full Text PDF

Purpose: To ascertain the refractive accuracy of 36 intraocular lens (IOL) power calculation formulas in unoperated eyes.

Design: Retrospective accuracy and validity analysis.

Participants: Six hundred fifty-five patients undergoing phacoemulsification and implantation of the Tecnis 1 ZCB00 IOL (Johnson & Johnson Vision, Jacksonville, FL, USA).

View Article and Find Full Text PDF

Comparison of the accuracy of twenty intraocular lens power calculation formulas in long eyes.

Asia Pac J Ophthalmol (Phila)

June 2025

Institute for Research in Ophthalmology, Foundation for Ophthalmology Development, Poznan 61-553, Poland; Department of Ophthalmology, University of Warmia and Mazury, Olsztyn 10-720, Poland. Electronic address:

Purpose: To compare the accuracy of twenty intraocular lens (IOL) power calculation formulas in long eyes (26.00-29.99 mm) DESIGN: Retrospective accuracy and validity analysis METHODS: The data of patients who underwent uneventful phacoemulsification between August 2019 and July 2024 were reviewed.

View Article and Find Full Text PDF