98%
921
2 minutes
20
Purpose: To investigate the accuracy of the VRF intraocular lens (IOL) power calculation formula in cataract patients after radial keratotomy (RK).
Methods: This was a retrospective study that reviewed and retrieved the medical history of patients after RK who underwent cataract surgery from April 1, 2021, to December 31, 2024, at Beijing Tongren Hospital. A total of 50 eyes of 27 patients were included. The absolute error (AE, the absolute value of the difference between the actual Spherical Equivalent after cataract surgery and the Equivalent Spherical predicted by the IOL formulas) and the percentage of eyes with AE within 0.5D, 0.75D, 1.0D, and 2.0D were calculated by using three formulas: the VRF formula, the Kane formula and the Barrett True-K No History formula and were compared.
Results: There was a significant difference in AE values between the three formulas (X = 33.556, p < 0.001), with the VRF formula having the smallest median AE value (MedAE) of 0.580D, followed by the Kane formula (0.585D), and the Barrett True-K No History formula (0.670D) the largest. Using the VRF formula, the percentages of eyes with AE within 0.5D, 0.75D, 1.0D, and 2.0D were 48%, 66%, 78%, and 94%, respectively, which were equal to or higher than the other two formulas.
Conclusion: For this cohort of patients with cataract after RK, the VRF formula was the most accurate, and the Kane formula also demonstrated good accuracy. Both formulas can be tried to be applied to predict IOL power in patients with cataract after RK in future clinical practice.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10792-025-03645-9 | DOI Listing |
Vet Res Forum
May 2025
Razi Vaccine and Serum Research Institute (RVSRI), Agricultural Research, Education, and Extension Organization (AREEO), Karaj, Iran.
The aim of this study was to using purified chicken antibody (IgY) for developing solid phase competitive (SPC) enzyme-linked immunosorbent assay (ELISA) to detect the foot-and-mouth disease virus (FMDV) A serotype. After immunization of chickens, polyclonal immunoglobulin (IgY) antibodies were extracted and purified from egg yolk and yield was about 5.00 mg mL of yolk as well as near 0.
View Article and Find Full Text PDFInt Ophthalmol
July 2025
Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, 100730, China.
Purpose: To investigate the accuracy of the VRF intraocular lens (IOL) power calculation formula in cataract patients after radial keratotomy (RK).
Methods: This was a retrospective study that reviewed and retrieved the medical history of patients after RK who underwent cataract surgery from April 1, 2021, to December 31, 2024, at Beijing Tongren Hospital. A total of 50 eyes of 27 patients were included.
J Endod
May 2025
Department of Oral Diagnosis - Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo, Brazil.
Introduction: Vertical root fractures (VRFs) detection in cone-beam computed tomography (CBCT) images can be challenging when gutta-percha artifacts are present. This study aimed to evaluate how anteroposterior and laterolateral head angulations (APHA and LLHA, respectively), as well as tooth position (anterior or posterior region), influence the diagnostic accuracy of VRFs detection in CBCT for endodontically treated teeth.
Methods: Twenty single-rooted teeth were endodontically treated.
Am J Ophthalmol
September 2025
IRCCS (G.S.), Fondazione G.B. Bietti, Rome.
Purpose: To ascertain the refractive accuracy of 36 intraocular lens (IOL) power calculation formulas in unoperated eyes.
Design: Retrospective accuracy and validity analysis.
Participants: Six hundred fifty-five patients undergoing phacoemulsification and implantation of the Tecnis 1 ZCB00 IOL (Johnson & Johnson Vision, Jacksonville, FL, USA).
Asia Pac J Ophthalmol (Phila)
June 2025
Institute for Research in Ophthalmology, Foundation for Ophthalmology Development, Poznan 61-553, Poland; Department of Ophthalmology, University of Warmia and Mazury, Olsztyn 10-720, Poland. Electronic address:
Purpose: To compare the accuracy of twenty intraocular lens (IOL) power calculation formulas in long eyes (26.00-29.99 mm) DESIGN: Retrospective accuracy and validity analysis METHODS: The data of patients who underwent uneventful phacoemulsification between August 2019 and July 2024 were reviewed.
View Article and Find Full Text PDF