Article Abstract

Background: The detection and quantification of changes in white matter lesions in the brain is important to monitor treatment effects in patients with multiple sclerosis (MS). Existing automatic tools predominantly require FLAIR images as input which are not always available, or only focus on new/enlarging activity. Therefore, we developed and validated a semi-automated method to quantify lesion volume changes based on 2D proton-density (PD)-weighted images and image subtraction. This semi-automated method provides insight in both "positive" activity (defined as new and enlarging lesions) and "negative" activity (disappearing and shrinking lesions).

Methods: Yearly MRI scans of patients with early MS from the REFLEX/REFLEXION studies were used. The maximum follow-up period was 5 years. Two PD-weighted images were normalized, registered to a common halfway-space, intensity-matched, and subsequently subtracted. Within manual lesion masks, lesion changes were quantified using a subtraction intensity threshold and total lesion volume change (TLVC) was calculated. Reproducibility was measured by assessing transitivity, specifically, we calculated the intraclass correlation coefficient for the absolute agreement (ICC) and the difference (Δ) between the direct one-step and indirect multi-step measurements of TLVC between two visits. Accuracy was assessed by calculating both the intraclass correlation coefficient for absolute agreement (ICC) and the difference (Δ) between the one-step semi-automated TLVC and manually measured lesion volume change (numerical difference) between two visits. Spearman's correlations (r) were used to assess the relation of global and central atrophy, manually measured T2 lesion volume, and lesion volume change with the method's performance as reflected by the difference measures |Δ| and Δ. An alpha of 0.05 was used as the cut-off for significance.

Results: Reproducibility was excellent, with ICC values ranging from 0.90 to 0.96. Accuracy was good overall, with ICC values ranging from 0.67 to 0.86. The standard deviation of Δ ranged from 0.25 to 0.86 mL. The mean of Δ ranged from 0.11 to 0.37 mL and was significantly different from zero. Both global and central atrophy significantly correlated with lower reproducibility (correlation of |Δ| with global atrophy, r = -0.19 to -0.28, and correlation of |Δ| with central atrophy, r = 0.22 to 0.34). There was generally no significant correlation between global/central atrophy and accuracy. Higher lesion volume was significantly correlated with lower reproducibility (r = 0.62). Higher lesion volume change was significantly correlated with lower reproducibility (r = 0.22) and lower accuracy (correlation of Δ with lesion volume change, r = -0.52).

Discussion: The semi-automated method to quantify lesion volume changes has excellent reproducibility and overall good accuracy. The amount of atrophy and especially lesion volume (change) should be taken into account when applying this method, as an increase in these variables might affect the quality of the results.

Conclusion: Overall, the semi-automated subtraction method allows a valid and reliable quantitative investigation of lesion volume changes over time in (early) MS for follow-up periods up to 5 years.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12172906PMC
http://dx.doi.org/10.1016/j.ynirp.2023.100194DOI Listing

Publication Analysis

Top Keywords

lesion volume
48
volume change
24
semi-automated method
16
volume changes
16
lesion
14
method quantify
12
quantify lesion
12
volume
12
central atrophy
12
correlated lower
12

Similar Publications

Postoperative aphasia (POA) is a common complication in patients undergoing surgery for language-eloquent lesions. This study aimed to enhance the prediction of POA by leveraging preoperative navigated transcranial magnetic stimulation (nTMS) language mapping and diffusion tensor imaging (DTI)-based tractography, incorporating deep learning (DL) algorithms. One hundred patients with left-hemispheric lesions were retrospectively enrolled (43 developed postoperative aphasia, as the POA group; 57 did not, as the non-aphasia (NA) group).

View Article and Find Full Text PDF

Background And Purpose: White matter hyperintensity (WMH) impairs cognitive function but is not evident in the early stage, raising the need to explore the underlying mechanism. We aimed to investigate the potential role of network structure-function coupling (SC-FC coupling) in cognitive performance of WMH patients.

Methods: A total of 617 participants with WMH (mean age = 61 [SD = 8]; 287 females [46.

View Article and Find Full Text PDF

One- versus two-stent stenting strategies in coronary bifurcation lesions.

J Invasive Cardiol

September 2025

Minneapolis Heart Institute and Minneapolis Heart Institute Foundation, Abbott Northwestern Hospital, Minneapolis, Minnesota. Email:

Objectives: Additional studies are needed on the follow-up outcomes of 1- vs 2-stent techniques in bifurcation percutaneous coronary interventions (PCI).

Methods: The authors examined the angiographic and procedural characteristics, and outcomes of 1306 bifurcation PCIs (1139 patients) performed at 6 centers between 2014 and 2024 from the PROGRESS-BIFURCATION registry.

Results: Upfront 1-stent PCI (96.

View Article and Find Full Text PDF

Purpose: To build computed tomography (CT)-based radiomics models, with independent external validation, to predict recurrence and disease-specific mortality in patients with colorectal liver metastases (CRLM) who underwent liver resection.

Methods: 113 patients were included in this retrospective study: the internal training cohort comprised 66 patients, while the external validation cohort comprised 47. All patients underwent a CT study before surgery.

View Article and Find Full Text PDF

Patients with inflammation-associated coronary artery disease (CAD) may exhibit rapid progression and require regular coronary imaging. To evaluate the diagnostic performance of spectral photon-counting detector (PCD) coronary CTA with reduced radiation and contrast media doses for detecting coronary stenosis and in-stent restenosis in patients with inflammation-associated CAD. This prospective study enrolled patients with inflammation-associated CAD from January 2023 to March 2024.

View Article and Find Full Text PDF