Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Phase measuring deflectometry (PMD) has been extensively applied to measure specular surfaces due to its non-contact, high-precision, full-field measurement capabilities. Liquid crystal display (LCD) screen is the most common structured light source in PMD. However, the response time of liquid crystal molecules limits its frame rate to around 100 frames per second (fps). Therefore, it is quite difficult for traditional PMD to measure rapidly moving surfaces. This paper proposes a 3D dynamic sensing technique, microsecond-PMD (µPMD) based on the high-frame-rate sinusoidal fringe display (HSFD). In the proposed method, the switching time for each fringe pattern display is at a sub-microsecond level, enabling high-speed fringe acquisition with kHz-level area array detection or 100kHz-level line array scanning. The HSFD method uses a specially designed LED array and two-step optical expansion. The high-speed switching characteristic of LED sources is utilized to allow a superfast display rate. Moreover, the superior sinusoidal property can be achieved by the combination of the specially designed discrete sinusoidal LED array, the light-diffracting effect of orthogonal gratings, and the filtering effect of the light diffuser. The mechanism and analytic model of fringe generation are thoroughly analyzed and discussed in this work. Furthermore, the swarm optimization algorithm and corresponding weighted fringe quality evaluation function are presented to obtain the optimal fringes. To the best of our knowledge, the proposed µPMD, for the first time, achieved a superfast fringe acquisition rate of 4000fps with sub-micrometer precision in three-dimensional (3D) reconstruction for specular surfaces. We envision this proposal to be broadly implemented for real-time monitoring in manufacturing.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.534047DOI Listing

Publication Analysis

Top Keywords

specular surfaces
12
liquid crystal
8
fringe acquisition
8
specially designed
8
led array
8
fringe
6
ultra high-speed
4
high-speed shape
4
shape measurement
4
measurement technology
4

Similar Publications

Vision-Ray-Calibration-Based Monocular Deflectometry by Poses Estimation from Reflections.

Sensors (Basel)

August 2025

State Key Laboratory of Special Vehicle Design and Manufacturing Integration Technology, Baotou 014030, China.

A monocular deflectometric system comprises a camera and a screen that collaboratively facilitate the reconstruction of a specular surface under test (SUT). This paper presents a methodology for solving the slope distribution of the SUT utilizing pose estimation derived from reflections, based on vision ray calibration (VRC). Initially recorded by the camera, an assisted flat mirror in different postures reflects the patterns displayed by a screen maintained in a constant posture.

View Article and Find Full Text PDF

To address the challenges of manual inspection dependency, low efficiency, and high costs in evaluating the surface grinding quality of composite materials, this study investigated machine vision-based surface recognition algorithms. We proposed a multi-scale texture fusion analysis algorithm that innovatively integrated luminance analysis with multi-scale texture features through decision-level fusion. Specifically, a modified Rayleigh parameter was developed during luminance analysis to rapidly pre-segment unpolished areas by characterizing surface reflection properties.

View Article and Find Full Text PDF

Fringe projection profilometry (FPP) based on structured light is widely used for three-dimensional (3D) shape measurement due to its non-contact nature and high accuracy. However, in practical measurement scenarios, the surface reflectivity of objects varies significantly, leading to a mix of specular and diffuse reflections. This results in the coexistence of underexposed and overexposed areas, which remains a challenging issue in FPP.

View Article and Find Full Text PDF

In defect detection through machine vision, imaging quality significantly impacts subsequent detection accuracy, especially with specular surfaces presenting challenges due to high reflectivity. This paper aims to enhance defect imaging on specular surfaces. We propose a defect detection system utilizing structured lighting and light field cameras to efficiently capture various types of specular defects.

View Article and Find Full Text PDF

The retrieval of sea surface normal vectors using shape-from-polarization is investigated for the purpose of correcting for refraction at the water-air interface when imaging from above the water. In shallow clear water and overcast conditions, spectral longpass filtering (using a hard-coated 850 nm cut-on wavelength filter) is demonstrated to 1) avoid artifacts from the ground in the measured polarization state, and 2) reduce polarization from water-leaving radiance sufficiently to derive shape information exclusively from the polarization produced by specular reflection. The dependence of the method on meteorological conditions is studied.

View Article and Find Full Text PDF