98%
921
2 minutes
20
To integrate implicit templates with deep learning techniques, a novel neural network, the tooth-deformable deep implicit network (T-DDIN), was constructed to achieve high-precision shape completion of tooth defects in a personalized manner. A total of 550 intraoral scan models were collected from patients treated at the Department of Orthodontics and Department of Prosthodontics, West China Hospital of Stomatology, Sichuan University (500 for training and 50 for testing), between March 2022 and March 2024. T-DDIN reconstructed defective tooth morphology using an implicit template and a latent encoding prediction network. During model evaluation, Class Ⅱ cavity defects and occlusal wear defects were simulated in the test set. Morphological restoration was performed using both traditional computer aided design (CAD) methods and the T-DDIN deep learning approach. The two methods were compared based on three-dimensional deviation, occlusal adjustment volumes, cusp angle deviation, and restoration time. The T-DDIN group demonstrated significantly lower three-dimensional deviation for Class Ⅱ cavity defects and occlusal wear restoration [(0.14±0.05) and (0.16±0.09) mm], occlusal adjustment volumes [(0.44±0.03) and (0.49±0.03) mm], and difference value of the tooth cusp angles (5.69°±1.90° and 6.04°±0.53°) compared to the traditional CAD group (both <0.001). No significant differences were observed within the T-DDIN group between the two defect types in terms of three-dimensional deviation (=0.098) or occlusal adjustment volume (=0.154) or difference value of the tooth cusp angles (=0.196). However, in the traditional CAD group, three-dimensional deviation, occlusal adjustment volume and difference value of the tooth cusp angles was significantly higher in occlusal wear restorations than in Class Ⅱ cavity defects restorations (<0.001). The T-DDIN group, which involved Class Ⅱ cavity defects and occlusal wear, demonstrated significantly less recovery time of morphology (37.2±7.7) and (39.4±6.2) s compared to the traditional CAD group (<0.001). T-DDIN demonstrated superior stability and accuracy in morphological reconstruction for various types of dental defects while significantly reducing restoration time.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3760/cma.j.cn112144-20250331-00110 | DOI Listing |
Braz Oral Res
September 2025
Ankara University, Faculty of Dentistry, Department of Oral and Maxillofacial Radiology, Ankara, Turkey.
The aim of this in-vitro study was to verify which field of view (FOV) in cone-beam computed tomography (CBCT) yields greater accuracy in the detection of internal root resorption (IRR) volume, in comparison to the gold standard of micro-computed tomography (micro-CT) and to a physical method. Twenty-five extractedsingle-rooted teeth were scanned by CBCT with two different FOV parameters (6x6-FOV and 10x10-FOV) and via micro-CT. The volume of dental hard tissue was measured on these images.
View Article and Find Full Text PDFBraz Oral Res
September 2025
Universidade de Passo Fundo - UPF, School of Dentistry, Post-Graduation Program in Dentistry, Passo Fundo, RS, Brazil.
This study evaluated the influence of a customized healing abutment (CHA) placed on immediate implants. It also assessed bone ridge volume, keratinized mucosal collar, and postoperative pain. Thirty-one patients needing tooth extraction and immediate implant were selected.
View Article and Find Full Text PDFAust Endod J
September 2025
State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases, Department of Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu, Sichuan, China.
This study aimed to investigate the biomechanical impact of root canal anatomical variations and restoration techniques on endodontically treated mandibular second molars using finite element analysis. Five root morphologies were modelled: separated-rooted (S), fused-rooted with V-shaped (F-V), U-shaped (F-U) or Ω-shaped (F-Ω) radicular grooves and single-canal fused-rooted (F-O). Micro-CT scans were performed before and after endodontic instrumentation to generate the finite element models: intact teeth, post-and-core crowns with 2- to 3-mm ferrules and endocrowns with 3- to 4-mm pulp chamber extensions.
View Article and Find Full Text PDFOrthod Craniofac Res
September 2025
Department of Maxillofacial Orthognathics, Graduate School of Medical and Dental Sciences, Institute of Science Tokyo, Tokyo, Japan.
Objective: It is well-established that occlusion and dental arch form are related to the morphology and function of the oral soft tissues. Oral soft tissue dynamic assessment is important for elucidating the causes of malocclusion and developing effective treatment methods. We previously developed a small mouthguard-type sensing device for measuring oral soft tissue pressure; however, its continuous measurement performance had not been thoroughly evaluated.
View Article and Find Full Text PDFAnat Rec (Hoboken)
September 2025
Department of Anatomy, Midwestern University, Glendale, Arizona, USA.