Article Abstract

Nocturnal monitoring of continuous, cuffless blood pressure (BP) can unleash a whole new world for the prognostication of cardiovascular and other diseases due to its strong predictive capability. Nevertheless, the lack of an accurate and reliable method, primarily due to confounding variables, has prevented its widespread clinical adoption. Herein, we demonstrate how optimized machine learning using the Catch-22 features, when applied to the photoplethysmogram waveform and personalized with direct BP data through transfer learning, can accurately estimate systolic and diastolic BP. After training with a hemodynamically compromised VitalDB "calibration-free" dataset (n = 1293), the systolic and diastolic BP tested on a distinct VitalDB dataset that met AAMI criteria (n = 116) had acceptable error biases of -1.85 mm Hg and 0.11 mm Hg, respectively [within the 5 mm Hg IEC/ANSI/AAMI 80601-2-30, 2018 standard], but standard deviation (SD) errors of 19.55 mm Hg and 11.55 mm Hg, respectively [exceeding the stipulated 8 mm Hg limit]. However, personalization using an initial calibration data segment and subsequent use of transfer learning to fine-tune the pretrained model produced acceptable mean (-1.31 mm Hg and 0.10 mm Hg) and SD (7.91 mm Hg and 4.59 mm Hg) errors for systolic and diastolic BP, respectively. Levene's test for variance found that the personalization method significantly outperformed ( < 0.05) the calibration-free method, but there was no difference between three machine learning methods. Optimized multimodal Catch-22 features, coupled with personalization, demonstrate great promise in the clinical adoption of continuous, cuffless blood pressure estimation in applications such as nocturnal BP monitoring.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12109000PMC
http://dx.doi.org/10.3390/bioengineering12050493DOI Listing

Publication Analysis

Top Keywords

continuous cuffless
12
cuffless blood
12
blood pressure
12
systolic diastolic
12
accurate reliable
8
nocturnal monitoring
8
clinical adoption
8
machine learning
8
catch-22 features
8
transfer learning
8

Similar Publications

Hypertension is a major risk factor for cardiovascular diseases and all-cause mortality, making accessible and easy blood pressure (BP) measurement, such as cuffless methods, crucial for its prevention, detection, and management. Cuffless BP estimation using wearable cardiovascular signals via deep learning models (DLMs) offers a promising solution. However, implementation of the DLMs usually requires high computational cost and time.

View Article and Find Full Text PDF

This work introduces high-speed (390 Hz) speckle contrast optical spectroscopy (SCOS) to enable simultaneous measurements of multi-anatomic site microvascular blood volume and flow oscillations. Simultaneous blood flow and volume waveforms were extracted at two wavelengths on the wrist and finger, in reflectance and transmission mode, respectively. Blood volume changes (also known as photoplethysmography, or PPG) were determined based on intensity oscillations.

View Article and Find Full Text PDF

Since instantaneous large changes in blood pressure (BP) values would cause the stroke or even death, continuous BP estimation is essential and crucial. Nevertheless, traditional cuffed BP estimation devices are unable to perform continuous BP estimation. Therefore, there has been a growing interest in developing continuous cuffless BP estimation devices.

View Article and Find Full Text PDF

Wearable cuffless blood pressure (BP) technology is emerging as a critical tool for monitoring hypertension, the leading risk factor of most cardiovascular diseases. However, current cuffless BP methods are not accurate enough for clinical use, because they mainly use single or dual modalities/features as inputs for estimation. To address this challenge, we propose multimodal McBP-Net, built with hybrid CNN-LSTM architecture combing two-layer convolution operations with four-layer LSTMs to capture both local signal features and temporal dependencies for continuous dynamic beat-to-beat BP estimation.

View Article and Find Full Text PDF