98%
921
2 minutes
20
The mechanism by which myopia-managing spectacle lenses slow myopia progression remains controversial. Understanding the changes these lenses introduce to peripheral imaging properties helps shed light on this controversial issue. Given the difficulty of directly measuring these changes in clinical settings, this study combined experimental and modeling approaches to evaluate changes in images at the retina induced by myopia-managing lenses. Optical characteristics that may related to the efficacy of the lenses with concentric cylindrical annular refractive elements (CARE) in myopia control were investigated. Three lenses were evaluated: MyoCare (MC), MyoCare S (MCS), and a single vision (SV) lens with a custom-built physical eye model and optical simulations for the analysis. The simulated PSFs are consistent with the measured ones. PSF analysis showed that MC and MCS lenses produce discrete curves, resulting in remarkable distortion in the simulated retina images, especially for large eccentricities. Whether they increase or decrease contrast depends on the spatial frequencies and eccentricities. These lenses also increase retinal light intensity at different eccentricities. The positive power of the CARE structure introduces myopic defocus of less than 0.25 D at only a limited range of eccentricities. The proposed approaches present relatively straightforward techniques for evaluating the optical performance of myopia-managing spectacle lenses.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12047728 | PMC |
http://dx.doi.org/10.1364/BOE.546942 | DOI Listing |
J Refract Surg
September 2025
Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio.
Purpose: To report a case of acute and transient accommodative insufficiency after laser in situ keratomileusis (LASIK) due to coronavirus disease 2019 (COVID-19).
Methods: Case report and literature review.
Results: A 36-year-old man complained of acute blurred near vision 7 days after uneventful bilateral hyperopic LASIK, concurrent with the onset of COVID-19 infection.
J Refract Surg
September 2025
Purpose: To evaluate tilt, decentration, and axial stability of the Clareon toric intraocular lens (TIOL) (CNW0T3-9; Alcon Laboratories, Inc) over a 6-month follow-up period.
Methods: A single-center, prospective, interventional clinical trial was conducted with a study population of 130 eyes from 82 patients who received a Clareon TIOL. Tilt, decentration, and the aqueous depth were determined preoperatively and at 1 week and 6 months postoperatively using anterior segment optical coherence tomography (Casia 2; Tomey Corporation).
Purpose: To evaluate visual and refractive outcomes, visual quality, patient satisfaction, and spectacle independence 3 months after phacoemulsification with bilateral non-diffractive enhanced depth of focus (EDOF) lens implantation.
Methods: This study included 68 eyes of 34 consecutive patients, with 51.5% undergoing refractive lens exchange and 48.
J Refract Surg
September 2025
Purpose: To compare postoperative vault measurements between horizontal and vertical fixation of the Implantable Collamer Lens (ICL) (KS-AquaPORT; STAAR Surgical) when its size is determined using the KS formula.
Methods: This retrospective study analyzed 2,343 eyes from 1,275 patients who underwent myopic ICL implantation. Pre-operative anterior segment optical coherence tomography (AS-OCT) (CASIA 2; Tomey Corporation) was performed in both horizontal and vertical orientations.
J Refract Surg
September 2025
From the Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany and.
Purpose: To evaluate intraocular lens (IOL) power calculation of a non-diffractive extended depth of focus (EDOF) IOL after myopic laser in situ keratomileusis (LASIK) without historical data.
Methods: In this consecutive case series, patients who had undergone lens surgery with implantation of a non-diffractive EDOF IOL after myopic laser in situ keratomileusis (LASIK) at the Department of Ophthalmology, University Hospital Frankfurt, Frankfurt, Germany, were included. Preoperative assessments included biometry and tomography using Scheimpflug technology (Pentacam; Oculus Optikgeräte GmbH).