Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In naturally ventilated classrooms, the air quality and ventilation conditions rely heavily upon window and door opening behaviour of the class teacher. This study aimed to examine the impact of an Internet of Things (IoT)-based CO₂ self-surveillance display system (SAVE unit) on classroom air quality and thermal comfort. The visual-acoustic signalling of classroom ventilation conditions notified the class teacher for opening/closing of classroom doors and windows. The air quality data were collected across baseline (no alarm), S1 (visual alarm) and S2 (visual-acoustic alarm) scenarios. The alarm was triggered to notify a class teacher when CO₂ exceeded 1000 and 1500 ppm with different alarm schemes. Results showed a 19.5 % reduction in CO₂ with visual alarms and 19 % with visual-acoustic alarms. However, PM concentrations (PM₁₀, PM₂.₅, PM₁, PM₀.₁) increased due to window openings, though a daily average of PM₁₀ and PM₂.₅ remained within WHO safe limits. Teacher's decision to open or close windows was primarily influenced by classroom temperature. Higher CO concentration was observed during colder days (S2) due to windows kept closed to avoid uncomfortable classroom temperature and excessive use of heaters. The SAVE unit helped to effectively lowered CO₂, but it also led to higher energy consumption due to heat loss from open windows. While natural ventilation improved air quality, it highlighted the need for balancing energy efficiency and thermal comfort. A holistic signalling system that integrates temperature, air quality, and ventilation parameters would better guide teachers in managing classroom ventilation. Additionally, a school-level ventilation protocol based on IoT-based signalling is recommended to ensure consistent and effective air quality management. This study underscores the importance of real-time data-driven ventilation strategies to optimise indoor air quality, reduce exposure to pollutants, and maintain a comfortable learning environment in classrooms.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2025.179543DOI Listing

Publication Analysis

Top Keywords

air quality
32
quality ventilation
12
class teacher
12
air
8
classroom air
8
quality
8
ventilation
8
ventilation conditions
8
save unit
8
thermal comfort
8

Similar Publications

Aims/hypothesis: Severe hypoglycaemia events (SHE) remain frequent in people with type 1 diabetes despite advanced diabetes technologies. We examined whether time below range (TBR) 3.9 mmol/l (70 mg/dl; TBR70) or 3.

View Article and Find Full Text PDF

Background: Climate distress is a psychological reaction to adverse weather events and climate change. These events can increase people's vulnerability to develop psychiatric disorders like anxiety, depression, and PTSD particularly in disaster-prone regions like India.

Aim: To explore the relationship between climate distress and psychological impact with a particular emphasis on women, elderly, and other at risk populations who owing to their health vulnerabilities, lack of resources or social roles that make them dependent on others, experience stress in the face of climate change.

View Article and Find Full Text PDF

Differences in physicochemical and functional properties of from-concentrate and not-from-concentrate apple pomace: an investigation based on different drying methods.

J Sci Food Agric

September 2025

Key Laboratory of Agricultural Product Processing and Storage, Ministry of Agriculture and Rural Affairs, Institute of Food Science and Technology, Chinese Academy of Agricultural Sciences (CAAS), Beijing, China.

Background: Apple pomace (AP), a byproduct of apple processing, is nutrient-rich, and its properties are influenced by both the quality of the apples and the juice extraction process. Drying technology can enhance its economic utilization. This study compared the effects of industrial drum drying (ID) and laboratory hot-air drying, heat pump drying and freeze drying (FD) on the physicochemical, functional and structural properties of from-concentrate AP (FC-AP) and not-from-concentrate AP (NFC-AP).

View Article and Find Full Text PDF

Epidemiological studies have already established associations between air pollutants and adverse health outcomes, but the causal associations between air pollutants and chest pain (CP) and gingival pain (GP) remain unclear. This study aimed to explore the potential causal effects of air pollutants on CP and GP. Utilizing genome-wide association study summary statistics from European-ancestry populations, we conducted bidirectional two-sample Mendelian randomization (MR) analyses.

View Article and Find Full Text PDF

This study compared the effects of phosphorylated modified long-chain inulin (PF) with low (PF1), medium (PF3), and high (PF6) degrees of substitution on the rheological, thermal, gluten network depolymerization characteristics, and microstructure of unfrozen and frozen dough. The results showed that PF increased G', G", Tp, and ΔH of unfrozen and frozen dough. Gluten protein analysis revealed that PF significantly increased the SS and α-helix content in gluten, with 3 %FPF3 showing an 11.

View Article and Find Full Text PDF