Three Criteria of M-Type Spectrometers for Engineering.

Sensors (Basel)

School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.

Published: April 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Researchers frequently utilize the method of optical initial structure (MOIS) of Czerny-Turner (C-T) spectrometers for aberration-correction studies based on the coma-free equation. While effective, this method has limitations: small numerical apertures at slits (0.05-0.07) hinder weak signal detection; V or W-shaped variations in Airy disk across wavelengths; optical resolution depends on the radius of the collimating lens may not match detector resolution; and sequence patterns based on the spot diagrams cannot simulate the full width at half maximum (FWHM) under discrete sampling. To address these issues, using ray tracing and imaging equations, three criteria are proposed: luminous flux and aberration balance (LFAB), Airy disk variation at imaging points (ADVI), and optical-detector resolution matching (ORDR). A verification system with a 500-750 nm wavelength range and 0.4 nm resolution was designed. Results show that designing spectrometers based on these criteria increases the slit's numerical aperture to 0.11 while controlling aberrations. After optimization, the tangential Airy disk size decreased by 28% with variations within 3 μm. Discrete sampling indicates FWHM pixel errors remain within 1/2 pixel of the theoretical value, and FWHM is at least 2.5 pixels, satisfying stricter sampling requirements beyond Nyquist. Optimization only involves adjusting the image plane by 0.017 mm axially, 0.879 mm off-axis, and 0.48° eccentricity. This research strengthens spectrometer design theory and improves practical applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12030898PMC
http://dx.doi.org/10.3390/s25082439DOI Listing

Publication Analysis

Top Keywords

airy disk
12
three criteria
8
discrete sampling
8
criteria m-type
4
m-type spectrometers
4
spectrometers engineering
4
engineering researchers
4
researchers frequently
4
frequently utilize
4
utilize method
4

Similar Publications

Lateral resolving power is a critical performance metric in coherence scanning interferometry (CSI) for characterizing surface form and texture. Pupil modulation enhances lateral resolving power by reducing the Airy disk size within the point spread function (PSF). In modern metrology, the instrument transfer function (ITF) serves as a comprehensive metric for evaluating lateral resolving power.

View Article and Find Full Text PDF

High-fidelity tissue super-resolution imaging achieved with confocal spinning-disk image scanning microscopy.

Light Sci Appl

August 2025

Department of Biomedical Engineering, National Biomedical Imaging Center, College of Future Technology, Peking University, Beijing, China.

Super-resolution imaging has revolutionized our ability to visualize biological structures at subcellular scales. However, deep-tissue super-resolution imaging remains constrained by background interference, which leads to limited depth penetration and compromised imaging fidelity. To overcome these challenges, we propose a novel imaging system, confocal² spinning-disk image scanning microscopy (CSD-ISM).

View Article and Find Full Text PDF

Three Criteria of M-Type Spectrometers for Engineering.

Sensors (Basel)

April 2025

School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.

Researchers frequently utilize the method of optical initial structure (MOIS) of Czerny-Turner (C-T) spectrometers for aberration-correction studies based on the coma-free equation. While effective, this method has limitations: small numerical apertures at slits (0.05-0.

View Article and Find Full Text PDF

Fast segmentation and multiplexing imaging of organelles in live cells.

Nat Commun

March 2025

Zhejiang Provincial Engineering Research Center for Organelles Diagnostics and Therapy, Eastern Institute of Technology, Ningbo, Zhejiang, China.

Studying organelles' interactome at system level requires simultaneous observation of subcellular compartments and tracking their dynamics. Conventional multicolor approaches rely on specific fluorescence labeling, where the number of resolvable colors is far less than the types of organelles. Here, we use a lipid-specific dye to stain all the membrane-associated organelles and spinning-disk microscopes with an extended resolution of ~143 nm for high spatiotemporal acquisition.

View Article and Find Full Text PDF

Expanding super-resolution imaging versatility in organisms with multi-confocal image scanning microscopy.

Natl Sci Rev

September 2024

Department of Biomedical Engineering, College of Future Technology, Peking University, Beijing 100871, China.

Resolving complex three-dimensional (3D) subcellular dynamics noninvasively in live tissues demands imaging tools that balance spatiotemporal resolution, field-of-view and phototoxicity. Image scanning microscopy (ISM), as an advancement of confocal laser scanning microscopy, provides a 2-fold 3D resolution enhancement. Nevertheless, the relatively low imaging speed has been the major obstacle for ISM to be further employed in imaging of biological tissues.

View Article and Find Full Text PDF