98%
921
2 minutes
20
The relationship between degree of coronary artery stenosis and its effect on myocardial perfusion is complex and constitutes a clinical challenge. The aim of this study was to assess diagnostic accuracy of visual assessment of invasive coronary angiography (ICA) for detecting reduced myocardial perfusion determined by quantitative first-pass perfusion (qFPP) cardiac magnetic resonance (CMR) in patients with suspected or established chronic coronary syndrome (CCS). Forty-nine patients with suspected or established CCS were included from the elective ICA list in this prospective, observational study and underwent qFPP CMR prior to ICA. Myocardial perfusion at stress and myocardial perfusion reserve (MPR) were assessed for each vessel territory. Myocardial perfusion at stress <2.0 ml/min/g and MPR <2.4 were considered abnormal. Visually assessed coronary artery stenoses from ICA were considered significant if ≥70%. Sensitivity and specificity of visual assessment of ICA for detecting significant reduction of myocardial perfusion ranged between 32%-41% and 70%-76% on a per vessel level depending on myocardial perfusion measure used as reference. Accuracy ranged between 0.48-0.64. In 59%-68% of vessel territories with reduced stress perfusion or MPR, no significant stenosis was found. Thus, visual assessment of ICA has limited diagnostic accuracy for detecting significant reduction of myocardial perfusion assessed by qFPP CMR in patients with suspected or established CCS. Hence, quantitative myocardial perfusion is required when evaluating the cause of angina to distinguish between coronary stenosis, microvascular dysfunction and non-cardiac causes of chest pain.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.amjcard.2025.03.027 | DOI Listing |
PLoS One
September 2025
Department of Cardiac Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
Background: Cardiac ischemia reperfusion (I/R) injury is a serious consequence of reperfusion therapy for myocardial infarction (MI). Peptidylarginine deiminase 4 (PAD4) is a calcium-dependent enzyme that catalyzes the citrullination of proteins. In previous studies, PAD4 inhibition protected distinct organs from I/R injury by preventing the formation of neutrophil extracellular traps (NETs) and attenuating inflammatory responses.
View Article and Find Full Text PDFCancer Biother Radiopharm
September 2025
Men's Health and Reproductive Health Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Intense hepatobiliary uptake of [Tc]Tc-sestamibi in myocardial perfusion scintigraphy (MPS) often degrades image quality by obscuring the inferior myocardial wall, leading to equivocal studies. While nonpharmacological interventions are inconsistent, the choleretic agent ursodeoxycholic acid (UDCA) could potentially accelerate hepatic clearance. The effectiveness of a convenient, single-dose UDCA intervention has not been rigorously evaluated.
View Article and Find Full Text PDFInt J Numer Method Biomed Eng
September 2025
School of Mathematics and Statistics, University of Glasgow, Glasgow, UK.
Blood perfusion in cardiac tissues involves intricate interactions among vascular networks and tissue mechanics. Perfusion deficit is one of the leading causes of cardiac diseases, and modeling certain cardiac conditions that are clinically infeasible, invasive, or costly can provide valuable supplementary insights to aid clinicians. However, existing homogeneous perfusion models lack the complexity required for patient-specific simulations.
View Article and Find Full Text PDFRadiol Phys Technol
September 2025
Department of Cardiovascular Internal Medicine, NHO Kagoshima Medical Center, 8-1, Shiroyamacho, Kagoshima, Kagoshima, 892-0853, Japan.
In Tl myocardial perfusion single-photon emission computed tomography (SPECT), gastric wall uptake can impact the inferior wall. This study aimed to evaluate the effectiveness and usefulness of the masking on un-smoothed image (MUS) method for Tl myocardial perfusion SPECT. A hemispherical gastric wall phantom was created to simulate the gastric fundus located closest to the myocardium, and the activity was enclosed to achieve an SPECT count ratio against the myocardium equivalent to that observed in clinical practice.
View Article and Find Full Text PDFAcad Radiol
September 2025
Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan (J.Y.H., C.L.K., K.L.C.); College of Medicine, National Taiwan University, Taipei, Taiwan (J.Y.H., C.K.H., K.L.C., Y.W.W.); Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan (C.K
Rationale And Objectives: The prognostic implications of myocardial perfusion imaging (MPI) are imperative to provide proper management of coronary artery disease (CAD). This study aimed to quantify the long-term prognostic value of MPI under routine clinical conditions.
Materials And Methods: This single-center retrospective cohort study evaluated all-cause mortality and cause-specific survival according to MPI findings in patients with suspected or known CAD who underwent diagnostic evaluation or assessment of myocardial ischemia and viability in a tertiary referral cardiovascular center.