We evaluate the accuracy of intraocular lens (IOL) power calculation in the following formulas-Barrett True-K No History (BTKNH), EVO 2.0 Post-Hyperopic LASIK/PRK (EVO 2.0), Haigis-L, Pearl-DGS, and Shammas (SF)-with patients who have undergone cataract surgery at the Eye Unit of University of Campania Luigi Vanvitelli, Naples, Italy, and had prior hyperopic laser refractive surgery. A monocentric, retrospective, comparative study, including the charts of patients who had undergone cataract surgery and previous hyperopic laser refractive surgery, was retrospectively reviewed. Patients with no other ocular or systemic disease which might interfere with visual acuity results and no operative complications or combined surgery were enrolled. The mean absolute prediction error (MAE) was calculated for each formula and compared. Subgroup analysis based on the axial length and mean keratometry was performed. A total of 107 patients (107 eyes) were included. The MAE calculated with SF provided less accurate ( < 0.05) results when compared to both BTKNH and EVO 2.0 formulas. The MAE obtained using Haigis-L, EVO 2.0, Pearl-DGS, and BTKNH showed no significant differences. The analysis of the accuracy of the selected formulas shows no clear advantage in using one specific formula in standard cases, but in eyes where it is mandatory to reach the target refraction, SF should be avoided.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11943137 | PMC |
http://dx.doi.org/10.3390/jcm14061990 | DOI Listing |
J Refract Surg
September 2025
Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio.
Purpose: To report a case of acute and transient accommodative insufficiency after laser in situ keratomileusis (LASIK) due to coronavirus disease 2019 (COVID-19).
Methods: Case report and literature review.
Results: A 36-year-old man complained of acute blurred near vision 7 days after uneventful bilateral hyperopic LASIK, concurrent with the onset of COVID-19 infection.
J Refract Surg
September 2025
Department of Refractive Surgery, Shanghai Aier Eye Hospital, Shanghai.
Purpose: To analyze the effects of ablation interruption on ablation depths and clinical refractive outcomes to characterize the impact of ambient temperature changes and ablation interruption on ocular surface temperature (OST) during excimer laser ablation.
Methods: This prospective study was conducted on laser ablations in polymethylmethacrylate (PMMA) plates and porcine corneas to simulate laser in situ keratomileusis (LASIK) treatments using the EX500 laser (Alcon Laboratories, Inc) at ambient temperatures of 18, 20, and 22 °C. Ablation interruption was performed for 1, 2, 3, 4, and 5 seconds at the 10th second of the treatment of -9.
J Refract Surg
September 2025
Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, China.
Purpose: To evaluate axis-dependent visual and refractive outcomes of small incision lenticule extraction (SMILE) in patients with interocular astigmatic axis discordance.
Methods: Seventy-five patients (150 eyes) with interocular astigmatic axis discordance were included in the study. Based on interocular axis combinations, patients were stratified into three cohorts: with-the-rule (WTR)/against-the-rule (ATR) (n = 19), WTR/oblique astigmatism (OA) (n = 39), and ATR/OA (n = 17).
J Refract Surg
September 2025
Purpose: To discuss the technique and outcome of what the authors called the "flap-in-flap" technique and report its safety as a procedure for correction of post-laser in situ keratomileusis (LASIK) myopic regression.
Methods: Seven eyes of 4 patients were included in this study. All patients had previously undergone LASIK for compound myopic astigmatism using the Moria M2 micro-keratome (Moria) 8 to 12 years prior to presentation.
J Refract Surg
September 2025
Department of Refractive Surgery, Aier Eye Hospital, Jinan University, Guangzhou, Guangdong, China.
Purpose: To report the refractive outcome of femtosecond laser-assisted lenticule intrastromal keratoplasty (LIKE) in correcting moderate to high hyperopia. Intraoperative effective optical zone (EOZ), centration offset, and postoperative higher order aberrations (HOAs) were analyzed to better understand factors affecting postoperative outcomes.
Methods: This was a prospective, consecutive case series study of LIKE for correcting hyperopia in one department from 2018 to 2023.