Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Dengue Virus (DENV) is a life-threatening pathogen leading to dengue fever, which brings about huge public health challenges globally. However, traditional detection methods currently fail to meet the increasing demands of clinic practice in terms of speed, simplicity, and accuracy. To address these limitations, we developed a novel, rapid, and highly sensitive diagnostic method for universal DENV detection by integrating recombinase polymerase amplification (RPA) assay and the Clustered Regularly Interspaced Short Palindromic Repeat (CRISPR) and associated (Cas) protein 12a (CRISPR/Cas12a) system into one-pot. This approach achieves exceptional sensitivity and specificity for DENV detection, with the entire process completed within 40 min, without the need for sophisticated equipment. The limit of detection (LOD) was determined to be 91.7 copies/test. Using this one-pot RT-RPA CRISPR/Cas12a detection system, all four serotypes of DENV (1 to 4) were successfully identified. In terms of specificity, the assay accurately detected DENV-infected positive samples without cross-reactivity with four other interfering viruses-infected samples (VSV, SeV, HSV-1 and IAV). Furthermore, we established a universal DENV RT-RPA-CRISPR/Cas12a-lateral flow dipstick (LFD) platform, which successfully identified all four serotypes of DENV with a sensitivity of approximately 250 copies/test. Collectively, our method not only provides a robust alternative for universal DENV detection but also offers valuable insights for the identification of other viruses.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11934806 | PMC |
http://dx.doi.org/10.1186/s12866-025-03882-z | DOI Listing |