98%
921
2 minutes
20
Purpose: Various specialized and general collimators are used for myocardial perfusion imaging (MPI) with single-photon emission computed tomography (SPECT) to assess different types of coronary artery disease (CAD). Alongside the wide variability in imaging characteristics, the apriori "learnt" information of left ventricular (LV) shape can affect the final diagnosis of the imaging protocol. This study evaluates the effect of prior information incorporation into the segmentation process, compared to deep learning (DL) approaches, as well as the differences of 4 collimation techniques on 5 different datasets.
Methods: This study was implemented on 80 patients database. 40 patients were coming from mixed black-box collimators, 10 each, from multi-pinhole (MPH), low energy high resolution (LEHR), CardioC and CardioD collimators. The testing was evaluated on a new continuous graph-based approach, which automatically segments the left ventricular volume with prior information on the cardiac geometry. The technique is based on the continuous max-flow (CMF) min-cut algorithm, which performance was evaluated in precision, recall, IoU and Dice score metrics.
Results: In the testing it was shown that, the developed method showed a good improvement over deep learning reaching higher scores in most of the evaluation metrics. Further investigating the different collimation techniques, the evaluation of receiver operating characterstic (ROC) curves showed different stabilities on the various collimators. Running Wilcoxon signed-rank test on the outlines of the LVs showed differentiability between the collimation procedures. To further investigate these phenomena the model parameters of the LVs were reconstructed and evaluated by the uniform manifold approximation and projection (UMAP) method, which further proved that collimators can be differentiated based on the projected LV shapes alone.
Conclusions: The results show that prior information incorporation can enhance the performance of segmentation methods and collimation strategies have a high effect on the projected cardiac geometry.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11893936 | PMC |
http://dx.doi.org/10.1186/s40658-025-00728-5 | DOI Listing |
PLoS One
September 2025
Department of Cardiac Surgery, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany.
Background: Cardiac ischemia reperfusion (I/R) injury is a serious consequence of reperfusion therapy for myocardial infarction (MI). Peptidylarginine deiminase 4 (PAD4) is a calcium-dependent enzyme that catalyzes the citrullination of proteins. In previous studies, PAD4 inhibition protected distinct organs from I/R injury by preventing the formation of neutrophil extracellular traps (NETs) and attenuating inflammatory responses.
View Article and Find Full Text PDFCancer Biother Radiopharm
September 2025
Men's Health and Reproductive Health Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Intense hepatobiliary uptake of [Tc]Tc-sestamibi in myocardial perfusion scintigraphy (MPS) often degrades image quality by obscuring the inferior myocardial wall, leading to equivocal studies. While nonpharmacological interventions are inconsistent, the choleretic agent ursodeoxycholic acid (UDCA) could potentially accelerate hepatic clearance. The effectiveness of a convenient, single-dose UDCA intervention has not been rigorously evaluated.
View Article and Find Full Text PDFInt J Numer Method Biomed Eng
September 2025
School of Mathematics and Statistics, University of Glasgow, Glasgow, UK.
Blood perfusion in cardiac tissues involves intricate interactions among vascular networks and tissue mechanics. Perfusion deficit is one of the leading causes of cardiac diseases, and modeling certain cardiac conditions that are clinically infeasible, invasive, or costly can provide valuable supplementary insights to aid clinicians. However, existing homogeneous perfusion models lack the complexity required for patient-specific simulations.
View Article and Find Full Text PDFRadiol Phys Technol
September 2025
Department of Cardiovascular Internal Medicine, NHO Kagoshima Medical Center, 8-1, Shiroyamacho, Kagoshima, Kagoshima, 892-0853, Japan.
In Tl myocardial perfusion single-photon emission computed tomography (SPECT), gastric wall uptake can impact the inferior wall. This study aimed to evaluate the effectiveness and usefulness of the masking on un-smoothed image (MUS) method for Tl myocardial perfusion SPECT. A hemispherical gastric wall phantom was created to simulate the gastric fundus located closest to the myocardium, and the activity was enclosed to achieve an SPECT count ratio against the myocardium equivalent to that observed in clinical practice.
View Article and Find Full Text PDFAcad Radiol
September 2025
Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan (J.Y.H., C.L.K., K.L.C.); College of Medicine, National Taiwan University, Taipei, Taiwan (J.Y.H., C.K.H., K.L.C., Y.W.W.); Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan (C.K
Rationale And Objectives: The prognostic implications of myocardial perfusion imaging (MPI) are imperative to provide proper management of coronary artery disease (CAD). This study aimed to quantify the long-term prognostic value of MPI under routine clinical conditions.
Materials And Methods: This single-center retrospective cohort study evaluated all-cause mortality and cause-specific survival according to MPI findings in patients with suspected or known CAD who underwent diagnostic evaluation or assessment of myocardial ischemia and viability in a tertiary referral cardiovascular center.