Article Abstract

Computational models are commonly used to investigate how the cortical bone microstructure affects fracture resistance; recently, phase-field models have been introduced for this purpose. However, experimentally measured material parameters for the microstructural tissues are lacking. Moreover, as no validation studies have been published, it remains unclear to what extent classical phase-field methods, assuming linear-elastic, brittle fracture, accurately represent bone. In this study, we address both these shortcomings by first applying a design-of-experiments methodology to calibrate a set of material parameters for a two-dimensional phase-field finite element model of bovine osteonal microstructure. This was achieved by comparing the outcomes from simulation to data from single-edge notched bending experiments on bovine osteonal bone and subsequent imaging of the crack path. Second, we used these parameters in new bone geometries to evaluate the parameters and the predictive performance of the model. Reasonable agreement was achieved between prediction and experiments in terms of peak load, crack initiation toughness and crack path. However, the model is unable to capture the experimentally observed gradual evolution of damage, leading to a nonlinear force response before the onset of visible crack extension. Nor does it capture the similarly observed increase in toughness with increasing crack length. These limitations are inherent to all classical phase-field methods since they originate from theories of brittle fracture, and alternative formulations are discussed. This is the first study attempting to validate classical phase-field methods in simulation of cortical bone fracture, and it highlights both potential and limitations to be addressed in future work.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12055898PMC
http://dx.doi.org/10.1007/s10237-025-01929-8DOI Listing

Publication Analysis

Top Keywords

cortical bone
12
classical phase-field
12
phase-field methods
12
bone microstructure
8
material parameters
8
brittle fracture
8
bovine osteonal
8
crack path
8
phase-field
6
crack
6

Similar Publications

Staphylococcus aureus manipulates osteocytes to cause persistent chronic osteomyelitis and antibiotic resistance via pyroptosis pathway suppression.

Drug Resist Updat

September 2025

Department of Orthopaedic Surgery, the First Affiliated Hospital, Fujian Medical University, Fuzhou, China; Department of Orthopaedic Surgery, National Regional Medical Center, Binhai Campus of the First Affiliated Hospital, Fujian Medical University, Fuzhou, China. Electronic address: fangxinyu0417

Aims: In chronic osteomyelitis, the cortical bone serves as the primary site for long-term persistence of Staphylococcus aureus (S. aureus), the present study aimed to explore the mechanisms of immune evasion and antibiotic resistance remain incompletely understood.

Methods: Clinical methicillin-resistant S.

View Article and Find Full Text PDF

A 37-year-old man presented with swelling and erythema in the left first toe after a prior trauma, suspicious for osteomyelitis. X-ray and computed tomography (CT) scans revealed a radiolucent lesion with cortical disruption. A 99mTc/tricine/HYNIC ubiquicidin 29-41 (UBI) scintigraphy showed increased uptake but a non-accumulative time-activity curve, indicating a false positive for infection.

View Article and Find Full Text PDF

Microstructure of the anterior iliac Spine: Identification of trends and relation to fracture tolerance.

J Mech Behav Biomed Mater

September 2025

Center for Applied Biomechanics, University of Virginia, 4040 Lewis and Clark Drive, Charlottesville, VA, 22911, United States.

Seatbelt-induced pelvic iliac wing injuries have been observed since the 1970s, but only recently has there been quantification of fracture tolerance and injury risk of the iliac wing. Previous studies have shown a wide variation in iliac wing fracture tolerance with no significant relationships to pelvis size, sex, or other factors. A weighted average bone density (BD) calculation of the entire iliac wing produced the best predictive performance of fracture tolerance in parametric (Weibull) survival models.

View Article and Find Full Text PDF

Impact of osteotomy angle on bone failure risk in a modified pull-through approach: a finite element analysis.

BMC Oral Health

September 2025

Department of Oral and Maxillofacial Surgery, Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, Berlin, Germany.

Background: A modified pull-through approach represents a promising treatment strategy to access tumors in the posterior oral cavity. The design of the wedge osteotomy plays a key role in preserving postoperative mechanical stability while enabling surgical access. However, the optimal osteotomy design to reduce fracture risk remains unclear.

View Article and Find Full Text PDF

Study of a near-cortical over-drilling technique on plate constructs with a conical locking system in a rabbit femoral fracture using a finite element model.

Med Eng Phys

October 2025

Centre for Simulation in Bioengineering, Biomechanics and Biomaterials (CS3B), Department of Mechanical Engineering, School of Engineering of Bauru, São Paulo State University (UNESP), Bauru, São Paulo, Brazil. Electronic address:

This study aimed to evaluate the near-cortical over-drilling technique on the mechanical behaviour of bone-plate constructs in a rabbit transverse femoral fracture. In vitro biomechanical testing and finite element (FE) models were used for analyses. Rabbits' bones (n = 14) were divided into two groups: G1 - without near-cortical over-drilling, and G2 - with near-cortical over-drilling.

View Article and Find Full Text PDF