Evaluation of Long-Term Performance of Six PM Sensor Types.

Sensors (Basel)

US Environmental Protection Agency Office of Research and Development, Research Triangle Park, Durham, NC 27711, USA.

Published: February 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

From July 2019 to January 2021, six models of PM air sensors were operated at seven air quality monitoring sites across the U.S. in Arizona, Colorado, Delaware, Georgia, North Carolina, Oklahoma, and Wisconsin. Common PM sensor data issues were identified, including repeat zero measurements, false high outliers, baseline shift, varied relationships between the sensor and monitor, and relative humidity (RH) influences. While these issues are often easy to identify during colocation, they are more challenging to identify or correct during deployment since it is hard to differentiate between real pollution events and sensor malfunctions. Air sensors may exhibit wildly different performances even if they have the same or similar internal components. Commonly used RH corrections may still have variable bias by hour of the day and seasonally. Most sensors show promise in achieving the U.S. Environmental Protection Agency (EPA) performance targets, and the findings here can be used to improve their performance and reliability further. This evaluation generated a robust dataset of colocated air sensor and monitor data, and by making it publicly available along with the results presented in this paper, we hope the dataset will be an asset to the air sensor community in understanding sensor performance and validating new methods.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11861664PMC
http://dx.doi.org/10.3390/s25041265DOI Listing

Publication Analysis

Top Keywords

air sensors
8
sensor monitor
8
air sensor
8
sensor
7
air
5
evaluation long-term
4
performance
4
long-term performance
4
performance sensor
4
sensor types
4

Similar Publications

Electrical Characterization of Indoor Air Quality in the Presence of Various Natural Air Purifiers.

ACS Omega

September 2025

Department of Electrical and Computer Engineering, North South University, Bashundhara, Plot # 15, Dhaka Division, Dhaka 1229, Bangladesh.

Air pollution is a critical threat to human health and the quality of life in large cities. In this work, we electrically characterized indoor air quality in Dhaka City with a microcontroller-based advanced sensing system in the presence of 60 air purifiers. We conducted LabVIEW-controlled, fully automated, and remotely operated experiments to precisely monitor, store, and analyze the air-purifying effects in the concentrations of air quality index (AQI) parametersPM2.

View Article and Find Full Text PDF

A novel smart textile swab was developed as an analytical tool for the onsite evaluation of biochemical changes in sweat toward potential applications in healthcare monitoring and drug testing. Betalain (BTA) was extracted from beetroot (Beta vulgaris L.) using a simple procedure.

View Article and Find Full Text PDF

Pediatric obstructive sleep apnea (OSA) is a common yet often underdiagnosed condition, partly due to limited access to polysomnography. Mandibular jaw movement (MJM) analysis offers a promising alternative to conventional home sleep apnea testing in children, capturing the dynamic interactions between respiratory drive and upper airway musculature, enabling accurate identification of, and critical insights into, sleep-disordered breathing events. This technical and practical review provides a structured framework for understanding and interpreting MJM signals during sleep in pediatric patients.

View Article and Find Full Text PDF

While fluorene-containing materials are widely used in organic optoelectronics as bright emitters and hole semiconductors, their diazafluorene analogues have been poorly explored, though their nitrogen atoms could result in electron transport and bring sensory abilities. Here, we report the synthesis, characterization, and detailed study of a series of 4,5-diazafluorene-derivatives with different donor/acceptor substituents and organic semiconductors based on these molecules. The crystal structures of all the materials were solved by X-ray diffraction, indicating the presence of extensive π-stacking and anisotropic charge-transfer pathways.

View Article and Find Full Text PDF

Modelling nitrogen dioxide dispersion in urban street canyons through sensor-based emission assessment.

J Environ Manage

September 2025

Department of Mechanical Engineering, University of Colorado Boulder, 1111 Engineering Drive, Boulder, CO, USA. Electronic address:

This study assesses the performance of the ADMS-Urban dispersion model in estimating 1-h mean nitrogen dioxide (NO) concentrations within the street canyons of Prague. While traditional air quality modeling that relies on sparse data from localized monitoring stations, this approach pioneers the integration of traffic, background, and rooftop sensor network, to archive a more granular validation of model outputs. The results demonstrate robust model performance, with FAC2 values ranging from 0.

View Article and Find Full Text PDF