98%
921
2 minutes
20
The majority of existing piezoelectric transducers work at a single resonant frequency, and their applications in scenarios with multi-frequency or frequency variation are not fully considered. Moreover, emitting high-energy ultrasound at different frequencies is also crucial. Here, we propose the three-frequency coupled vibration piezoelectric transducer, which exhibits higher emission performances. The proposed transducer is comprised of two rectangular piezoelectric ceramics, which are cut from a piece of rectangular piezoelectric ceramic. We derive the three-dimensional coupled vibration electromechanical equivalent circuit of the proposed transducer. Then, the characteristics of the transducer are numerically simulated. And comparison experiments between the proposed transducer and a piece of rectangular piezoelectric ceramic transducer were done. An ultrasonic water tank measurement system was used to measure their sound field, axial sound pressure, and transmitting voltage response. Experiments are conducted to verify the electromechanical and sound field characteristics of transducers, which are in good agreement with the simulated results and theoretical predictions. The proposed transducer can generate stable and stronger energy ultrasonic waves at three resonant frequencies. And this study can provide the theoretical and experimental references for multi-frequency conversion and high-energy ultrasonic radiation of the transducer.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1121/10.0035568 | DOI Listing |
Sci Adv
September 2025
State Key Laboratory for Manufacturing System Engineering, State Industry-Education Integration Center for Medical Innovations, International Joint Laboratory for Micro/Nano Manufacturing and Measurement Technologies, Shaanxi Innovation Center for Special Sensing and Testing Technology in Extreme En
Continuous monitoring of cardiovascular vital signs can reduce the incidence and mortality of cardiovascular diseases, yet cannot be implemented by current technologies because of device bulkiness and rigidity. Here, we report self-adhesive and skin-conformal ultrasonic transducer arrays that enable wearable monitoring of multiple hemodynamic parameters without interfering with daily activities. A skin-adaptive focused ultrasound method with rational array design is proposed to implement measurement under wide ranges of skin curvatures and depths with improved sensing performances.
View Article and Find Full Text PDFAdv Mater
September 2025
State Key Laboratory of Crystal Materials, Shandong University, Jinan, Shandong, 250100, P. R. China.
Electrical deep brain stimulation is effective for epilepsy suppression, but will lead to neural tissue damage and inflammation due to implantation of electrodes and a pulse generator. Transcranial magnetic and transcranial ultrasound stimulation cannot directly generate effective electrical signals in deep brain regions. Here, the use of piezoelectric nanoparticles is proposed as wireless nanostimulators for deep brain electrical stimulation and minimally invasive suppression of epilepsy.
View Article and Find Full Text PDFUltrasound Med Biol
September 2025
School of Electronic Science and Engineering, Nanjing University, Nanjing, Jiangsu, China. Electronic address:
Objective: Three-dimensional (3D) ultrasound imaging overcomes the limitations of 2D ultrasound images by providing comprehensive spatial information. However, challenges remain when imaging larger body parts like legs and arms using traditional linear transducer arrays. The main difficulties include limited scanning range and angle, bone interference that affects penetration depth, and registration difficulties caused by squeezing targets.
View Article and Find Full Text PDFTalanta
August 2025
Department of Molecular Tropical Medicine and Genetics, Faculty of Tropical Medicine, Mahidol University, Bangkok, 10400, Thailand. Electronic address:
A rapid and automated determination of nicotinamide adenine dinucleotide phosphate (NADPH) is proposed and applied to the evaluation of glucose-6-phosphate dehydrogenase (G6PD) deficiency in real samples. To this end, a sequential injection analyzer with electrochemical detection (SIA-ECD) is proposed with 0.1 mol L Tris-HCl (pH 8.
View Article and Find Full Text PDFIEEE Trans Biomed Eng
September 2025
Objective: coronary rotational atherectomy (CRA) is a vital method for the treatment of cardiovascular calcified blockages, but the lack of intravascular information may lead to improper setting of rotary parameters, posing risks of surgical complications. Forward-looking intravascular ultrasound (FL-IVUS) is a valuable tool for lumen imaging and has unique advantages in severely calcified or even occluded vessels.
Methods: in this study, a visual rotary surgical instrument based on FL-IVUS imaging was proposed to achieve intraoperative feedback.