98%
921
2 minutes
20
Objectives: Deuterium (H) Metabolic Imaging (DMI) is an emerging magnetic resonance technique to non-invasively map human brain glucose (Glc) uptake and downstream metabolism following oral or intravenous administration of H-labeled Glc. The achievable spatial resolution is limited due to inherently low sensitivity of DMI. This hinders potential clinical translation. The purpose of this study was to improve the signal-to-noise ratio (SNR) of 3D DMI via a balanced steady state free precession (bSSFP) acquisition scheme combined with fast non-Cartesian spatial-spectral sampling to enable high resolution dynamic imaging of neural Glc uptake and glutamate+glutamine (Glx) synthesis of the human brain at 7T.
Materials And Methods: Six healthy volunteers (2f/4m) were scanned after oral administration of 0.8 g/kg [6,6']-H-Glc using a novel density-weighted bSSFP acquisition scheme combined with fast 3D concentric ring trajectory (CRT) k-space sampling at 7T. Time-resolved whole brain DMI datasets were acquired for approximately 80 min (7 min per dataset) after oral H-labeled Glc administration with 0.75ml and 0.36ml isotropic spatial resolution and results were compared to conventional spoiled Free Induction Decay (FID) H-MRSI with CRT readout at matched nominal spatial resolution.Dynamic DMI measurements of the brain were accompanied by simultaneous systemic Glc measurements of the interstitial tissue using a continuous Glc monitoring (CGM) sensor (on the upper arm). The correlation between brain and interstitial Glc levels was analyzed using linear mixed models.
Results: The bSSFP-CRT approach achieved SNRs that were up to 3-fold higher than conventional spoiled FID-CRT H-MRSI. This enabled a 2-fold higher spatial resolution. Seventy minutes after oral tracer uptake comparable H-Glc, H-Glx and H-water concentrations were detected using both acquisition schemes at both, regular and high spatial resolutions (0.75ml and 0.36 ml isotropic). The mean Areas Under the Curve (AUC) for interstitial fluid Glc measurements obtained using a continuous Glc monitoring (CGM) sensor was 509±65 mM·min. This is 3.4 times higher than the mean AUC of brain Glc measurements of 149±43 mM·min obtained via DMI. The linear mixed models fitted to assess the relationship between CGM measures and brain H-Glc yielded statistically significant slope estimates in both GM (β = 0.47, = 0.01) and WM (β = 0.36, = 0.03).
Conclusion: In this study we successfully implemented a balanced steady state free precession (bSSFP) acquisition scheme for dynamic whole-brain human DMI at 7T. A 3-fold SNR increase compared to conventional spoiled acquisition allowed us to double the spatial resolution achieved using conventional FID-CRT DMI. Systemic continuous glucose measurements, combined with dynamic DMI, demonstrate significant potential for clinical applications. This could help to improve our understanding of brain glucose metabolism by linking it to time-resolved peripheral glucose levels. Importantly, these measurements are conducted in a minimally invasive and physiological manner.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11838661 | PMC |
http://dx.doi.org/10.1101/2025.02.06.25321580 | DOI Listing |
ACS Chem Neurosci
September 2025
Chemical and Biomolecular Engineering Dept, University of California, Los Angeles, Los Angeles, California 90095, United States.
Simulations in three dimensions and time provide guidance on implantable, electroenzymatic glutamate sensor design; relative placement in planar sensor arrays; feasibility of sensing synaptic release events; and interpretation of sensor data. Electroenzymatic sensors based on the immobilization of oxidases on microelectrodes have proven valuable for the monitoring of neurotransmitter signaling in deep brain structures; however, the complex extracellular milieu featuring slow diffusive mass transport makes rational sensor design and data interpretation challenging. Simulations show that miniaturization of the disk-shaped device size below a radius of ∼25 μm improves sensitivity, spatial resolution, and the accuracy of glutamate concentration measurements based on calibration factors determined .
View Article and Find Full Text PDFJ Am Chem Soc
September 2025
Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, Suzhou 215123, Jiangsu P. R. China.
Advances in molecular analysis and characterization techniques should revolutionize the methods for scientific exploration across physics, chemistry, and biology, fundamentally overturning our understanding of interactions and processes that govern molecular behavior at the microscopic level. Currently, the absence of a molecular analysis method that can both quantify molecules and achieve single-molecule spatial resolution hinders our study of complex molecular systems in sorption and catalysis. Here, we propose a quantitative analysis strategy for small molecules confined in ZSM-5, a zeolite material extensively used in catalysis and gas separation, based on low-dose transmission electron microscopy.
View Article and Find Full Text PDFNew Phytol
September 2025
Department of Ecology & Evolution, University of Chicago, Chicago, IL, 60637, USA.
Understanding the rate and nature of adaptation is crucial for managing biodiversity across our changing landscapes. This perspective synthesizes insights from resistance evolution - a case of rapid, repeated adaptation to extreme human-mediated selection - to reveal how adaptive genetic architectures determine and feedback with evolutionary dynamics. Recent population genomic and quantitative genetic approaches have demonstrated that the extent of genetic parallelism and reliance on de novo vs standing genetic variation can vary with the complexity of genetic architectures.
View Article and Find Full Text PDFNanoscale
September 2025
School of Mechanical Engineering, Shandong University of Technology, Zibo 255000, China.
Metal matrix composites are widely employed in aerospace and marine engineering due to their excellent mechanical properties and chemical stability. However, their surfaces remain vulnerable to corrosion, icing, and mechanical wear, severely compromising long-term reliability in harsh environments. Inspired by natural superhydrophobic surfaces such as lotus leaves, functional interfaces with high water repellency and interfacial stability can be engineered through the synergistic design of hierarchical micro/nanostructures and low-surface-energy chemical modifications.
View Article and Find Full Text PDFiScience
September 2025
Victor Chang Cardiac Research Institute, Darlinghurst, NSW 2010, Australia.
5-Ethynyl-2'-deoxyuridine (EdU) has revolutionized DNA replication and cell cycle analyses through fast, efficient click chemistry detection. However, commercial EdU kits suffer from high costs, proprietary formulations, limited antibody multiplexing capabilities, and difficulties with larger biological specimens. Here, we present OpenEMMU (Open-source EdU Multiplexing Methodology for Understanding DNA replication dynamics), an optimized, affordable, and user-friendly click chemistry platform utilizing off-the-shelf reagents.
View Article and Find Full Text PDF