Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In this paper, a simple chain suspension catenary model is constructed. The acting force of pantograph is reduced to a displacement loading. The stress and fatigue life of railway catenary dropper incorporating displacement loading and fluctuating wind load are studied. Through writing a MATLAB code, the vibration equation of the dropper is used to calculate its stress under different conditions using a finite difference method, combining with the initial boundary value conditions obtained by the response equations of the contact wire. Based on the dropper stress, its fatigue life can be obtained. The results show that under the 250 km/h train speed, the stress change process of the dropper experiences three stages: immediate rebound, attenuation vibration, and bending compression. Dropper Ⅳ is most likely to break in a span. Compared with dropper Ⅳ, the fatigue life of dropper Ⅰ is 11 times, and those of droppers Ⅱ, Ⅲ, and Ⅴ are about 2.5 times. Compared with no wind, the fatigue lives of droppers Ⅰ-Ⅳ are reduced by approximately three times at a wind speed of 25 m/s. This work provides a powerful means for the study of dropper stress under actual working condition.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11840857PMC
http://dx.doi.org/10.1177/00368504241311432DOI Listing

Publication Analysis

Top Keywords

displacement loading
12
fatigue life
12
dropper
9
railway catenary
8
catenary dropper
8
incorporating displacement
8
loading fluctuating
8
fluctuating wind
8
wind load
8
stress fatigue
8

Similar Publications

Effect of Drill Handle Force Applied to Digital Surgical Guides on Implant Deviation: An In Vitro Study.

Clin Implant Dent Relat Res

October 2025

State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu, China.

Introduction: This in vitro study evaluated how different forces applied to the dental drill handle during static computer-assisted implant surgery influence surgical guide deformation and implant placement accuracy.

Methods: Twenty-four virtual implants were divided into six groups (0-10 N, in 2 N increments). Surgical guides were scanned under loaded conditions, and deviations were quantified by superimposition with the baseline model.

View Article and Find Full Text PDF

Breaking points of human hamstring muscle-tendon complex: A cadaveric study.

J Mech Behav Biomed Mater

August 2025

Department of Physical Therapy, School of Health Sciences, Sapporo Medical University, Sapporo, Japan; Graduate School of Health Sciences, Sapporo Medical University, Sapporo, Japan. Electronic address:

Hamstring strain injuries frequently occur during the late swing phase of running; however, the breaking strength of the human hamstring muscle-tendon complexes remains unclear. This study aimed to determine the breaking strength of human hamstring muscle-tendon complexes. To this end, seven cadaveric specimens preserved using the Thiel's method were examined.

View Article and Find Full Text PDF

Although acutely donning compression garments improves several markers of athletic performance, the effects of training in compression garments remains largely unexplored. Thus, this study aimed to determine the effects of exercise training while donning a novel full-body compression garment on multiple measures of anaerobic performance. Sixteen sedentary males (age: 21±3 y; BMI: 25±3 kg/m) completed 4 weeks of training with (CG; n=8) or without (CON; n=8) a novel full-body compression garment.

View Article and Find Full Text PDF

Introduction: Patients with hemifacial microsomia exhibit varying degrees of mandibular asymmetry. The commercial plates used during bilateral sagittal split osteotomy (BSSO) surgery are often not tailored to individual patients and may lack sufficient fixation stability, increasing the risk of mandibular relapse. This study proposes a patient-specific plate design by collecting CT images of 30 cases of hemifacial microsomia to statistically analyze mandibular asymmetry.

View Article and Find Full Text PDF

Chronic wounds infected with multidrug-resistant bacteria pose a significant therapeutic challenge, requiring biocompatible and effective interventions. This study presents a novel lignin-based nanoparticle spray for the localized delivery of curcumin, a natural anti-inflammatory and antimicrobial compound. Lignin, a sustainable polyphenolic biopolymer with inherent antioxidant and antimicrobial activities, was used both as a carrier and functional agent.

View Article and Find Full Text PDF