Simultaneous Determination of Multiple Acid-Suppressing Drugs by UPLC-MS/MS Method and Application for Pharmacokinetics Study.

Drug Des Devel Ther

Clinical Pharmacology Research Center, Peking Union Medical College Hospital, NMPA Key Laboratory for Clinical Research and Evaluation of Drug, Beijing Key Laboratory of Clinical PK & PD Investigation for Innovative Drugs, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing

Published: May 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Proton pump inhibitors (PPIs) and potassium competitive acid blockers (P-CABs) are widely used to treat acid-related diseases (ARDs). Precisely quantifying their plasma levels is crucial for clinical pharmacokinetic assessments and therapeutic drug monitoring.

Aim: This study aimed to establish a generic and efficient ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) assay for the determination of five PPIs (esomeprazole, rabeprazole, ilaprazole, lansoprazole, and pantoprazole) and the P-CAB (vonoprazan) in human plasma.

Methods: The six analytes were extracted from human plasma via protein precipitation and a single dilution step. Detection was performed on a triple quadrupole tandem mass spectrometer with positive electrospray ionization. Chromatographic separation was achieved on the ACQUITY UPLC BEH C18 column (2.1 × 50 mm, 1.7 µm) using gradient elution. The mobile elution was composed of 0.2% formic acid in acetonitrile (mobile phase A), 0.1% ammonium hydroxide and 10 mmol/L ammonium formate in deionized water (mobile phase B). The flow rate was 0.4 mL/min, the run time was 4.5 minutes, and the injection volume was 20 µL.

Results & Conclusions: The method exhibited excellent linearity across the ranges of 0.2-200 ng/mL for PPIs and 0.5-500 ng/mL for the P-CAB. Both intra- and inter-day precision and accuracy were within the acceptance criteria, with precision ranging from 1.1% to 14.6% and accuracy ranging from 0.0% to 14.7%. Extraction recoveries were consistent, ranging from 88.1% to 96.7%, with no significant matrix effects observed. The stability of the six analytes under diverse storage and processing conditions was also confirmed, with both precision and accuracy falling within the acceptable range of 15%. The UPLC-MS/MS assay provided an efficient and reliable approach for the simultaneous determination of six acid-suppressing medications in a single analytical run. It has been successfully applied to the pharmacokinetic studies of PPIs and P-CABs, offering a valuable tool for clinical research and therapeutic drug monitoring.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11830758PMC
http://dx.doi.org/10.2147/DDDT.S493911DOI Listing

Publication Analysis

Top Keywords

simultaneous determination
8
therapeutic drug
8
uplc-ms/ms assay
8
mobile phase
8
precision accuracy
8
determination multiple
4
multiple acid-suppressing
4
acid-suppressing drugs
4
drugs uplc-ms/ms
4
uplc-ms/ms method
4

Similar Publications

A rapid and specific liquid chromatography-tandem mass spectrometry method with a wide linear range was developed and validated for the simultaneous quantification of Vitamin K1 (VK1) trans- and cis- isomers in human plasma. Bovine serum albumin solution (15%) served as a surrogate matrix for preparing the calibrators to establish the quantitative curves. After liquid-liquid extraction, VK1 trans- and cis- isomers in plasma samples were separated on a ChromCore C30 column (15 cm × 4.

View Article and Find Full Text PDF

The laboratory analysis of new psychoactive substances and related drugs is crucial for accurate clinical and forensic diagnosis of poisonings. Given this, a new LC-MS/MS method for analyzing hallucinogens, synthetic cathinones, and synthetic cannabinoids in urine was developed. Urine samples were extracted using a liquid-liquid extraction protocol optimized via a multivariate experimental design.

View Article and Find Full Text PDF

Development of smartphone-based AIE fluorescence-quenching immunochromatographic sensors for the detection of illicit drugs in various complex sample matrices.

Anal Bioanal Chem

September 2025

GuangDong Engineering Technology Research Center of Antibody Drug and Immunoassay, Department of Biological Sciences and Biotechnology, College of Life Science and Technology, Jinan University, Guangzhou, 510632, China.

Illicit drug abuse poses a significant global threat to public health and social security, highlighting the urgent need for rapid, sensitive, and versatile detection technologies. To address the limitations of traditional chromatographic techniques-such as high costs and slow response times-and the drawbacks of conventional immunochromatographic sensors (ICS), including low sensitivity and non-intuitive signal outputs, a fluorescence-quenching ICS (FQICS) was developed. This sensor leverages fluorescence resonance energy transfer (FRET) between aggregation-induced emission fluorescent microspheres (AIEFMs) and gold nanoparticles (AuNPs).

View Article and Find Full Text PDF

Zirconium disilicide (ZrSi) ceramics have excellent physical and chemical properties and are employed in aerospace, energy, and chemical industries. Currently, the preparation and properties of ZrSi ceramics have been less studied. To comprehensively study the characteristics of ZrSi ceramics, in this study, dense bulk ZrSi ceramic samples are successfully prepared by the high-pressure-high-temperature (HPHT) sintering technique.

View Article and Find Full Text PDF

Background: Tumor heterogeneity and antigen escape are mechanisms of resistance to chimeric antigen receptor (CAR)-T cell therapy, especially in solid tumors. Targeting multiple antigens with a unique CAR construct could be a strategy for a better tumor control than monospecific CAR-T cells on heterogeneous models. To overcome tumor heterogeneity, we targeted mesothelin (meso) and Mucin 16 (MUC16), two antigens commonly expressed in solid tumors, using a tandem CAR design.