98%
921
2 minutes
20
Background: Titration of oxygen therapy to target safe oxygen saturation (SpO) values is a vital part of care for preterm infants, but is difficult to achieve, particularly in settings in which oxygen, monitoring technology, and human resources are scarce. We aimed to evaluate the safety and efficacy of automated titration of oxygen therapy partnered with a low-cost continuous positive airway pressure (CPAP) device versus manual oxygen control in preterm infants requiring CPAP in a high-mortality, low-resource setting.
Methods: In this open-label, randomised, crossover trial, preterm infants with a gestational age younger than 34 weeks (or a birthweight <2 kg if gestation was unknown) who were aged 12 h or older and required CPAP and oxygen were recruited at two hospitals in southwest Nigeria. Participants were randomly assigned (1:1) to one of two intervention sequences (ie, to commence the study on automated oxygen control or manual oxygen control) with block randomisation (blocks of 4 and 6) and stratification by health facility. The study statistician was masked to treatment group assignment, but the participants' parents or caregivers and clinical staff were not. Participants received automated or manual oxygen control for two 24-h periods in random sequence. Automated oxygen titration was done with a control algorithm with proven efficacy in high-resource settings. During periods of manual control, oxygen therapy was adjusted by clinicians. The primary outcome was the adjusted mean difference in the proportion of time participants spent in the SpO target range (ie, SpO 91-95% when receiving oxygen or SpO 91-100% when not receiving oxygen) between automated and manual oxygen control, analysed by intention to treat with weighted repeated measures mixed model linear regression. This trial is registered with ClinicalTrials.gov, NCT05508308, and is completed.
Findings: Between Sept 13, 2022, and Sept 11, 2023, 72 infants were screened, and 49 (22 female, 27 male; median gestation 29 weeks [IQR 28-31]; median birthweight 1·2 kg [1·1-1·5]) were enrolled in the study and randomly assigned. A total of 80 study periods for 46 infants contributed data to the analysis of the primary outcome as three (6%) of the 49 participants had no oxygenation data from either study period. The mean proportion of time spent in the SpO target range was higher during automated control periods than during periods of manual control (adjusted mean 88·1% [95% CI 84·0-92·2] vs 30·1% [20·9-39·3]; adjusted mean difference 58·0% [95% CI 48·0-67·9]; p<0·0001). There were no device-related adverse patient outcomes and short-term safety outcomes favoured automated control.
Interpretation: Automated titration of oxygen partnered with a low-cost CPAP device improved time spent in the safe SpO range compared with manual control. There is high potential for this technology to mitigate the risk of oxygen-mediated complications in preterm infants in low-resource settings.
Funding: National Health and Medical Research Council Australia and University of Tasmania.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S2214-109X(24)00458-3 | DOI Listing |
BMC Pediatr
September 2025
Department of Neonatology, Zhangzhou Affiliated Hospital of Fujian Medical University, Zhangzhou, Fujian, China.
Background: Red blood cell (RBC) transfusion is a common intervention for anemia in preterm infants; however, its association with bronchopulmonary dysplasia (BPD) remains debated. While biological mechanisms suggest potential harm, the clinical impact of transfusion frequency on BPD incidence and severity remains unclear.
Objective: To investigate whether RBC transfusion frequency is independently associated with the risk and severity of BPD in preterm infants born before 32 weeks of gestation.
Turk J Pediatr
September 2025
Department of Anesthesiology, All India Institute of Medical Sciences, Patna, India.
Background: Umbilical arterial catheterisation is a common intervention performed in the neonatal intensive care unit (NICU) especially in extremely preterm and extremely low birth weight neonates. Rarely catheter fracture or breakage can occur, leaving behind part of the catheter in the aorta. A handful of cases have been reported in the literature, with the majority being managed surgically.
View Article and Find Full Text PDFJ Proteome Res
September 2025
Department of Pediatrics, Jagiellonian University Medical College, Wielicka 265 Street, 30-663 Krakow, Poland.
Premature infants are at high risk for brain injuries such as intraventricular hemorrhage and periventricular white matter injury. This study applies omics technology to analyze urinary protein expression, aiming to clarify preterm brain injury mechanisms and identify therapeutic targets. Urine samples were collected from 29 very preterm infants (VPI) without brain injury and 11 with moderate/severe injury at eight time points: Days 1, 2, 3, 4, 6, 8, 28, and term-equivalent age (TEA).
View Article and Find Full Text PDFJAMA Netw Open
September 2025
Perinatal Institute, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio.
Importance: Exposure to inflammation from chorioamnionitis places the fetus at higher risk of premature birth and may increase the risk of neurodevelopmental impairments, though the evidence for the latter is mixed.
Objective: To evaluate whether moderate to severe histologic chorioamnionitis (HCA) is directly associated with adverse motor performance, independent of the indirect mediating effects of premature birth.
Design, Setting, And Participants: This prospective, population-based cohort study recruited participants between September 16, 2016, and November 19, 2019, from referral and nonreferral neonatal intensive care units of 5 southwestern Ohio hospitals.
Arch Gynecol Obstet
September 2025
The First Affiliated Hospital of Soochow University, No. 899 Pinghai Street, Suzhou, Jiangsu, China.
Objective: The study utilized non-invasive myocardial work indices to investigate myocardial injury in infants born to mothers with severe preeclampsia (SPE) and to explore the duration of this myocardial damage during the neonatal period.
Methods: This prospective study included 34 preterm infants born to mothers with SPE and 28 preterm infants born to mothers without severe pregnancy complications (termed "controls"). Echocardiography was performed in infants within 24 h of birth, then again at 48-72 h and 14-28 days, to obtain echocardiographic parameters.