A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Simulation analysis of a photonic crystal fiber refractive index sensor based on a double-layer film structure and surface plasmon resonance technology. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A photonic crystal fiber surface plasmon resonance sensor based on a double-layer membrane structure is designed and analyzed. In the simple sensing structure with only one air hole size, and Au layers with specific thicknesses are sequentially coated on the optical fiber to form a double-layer structure. The sensing characteristics of the double-layer membrane structure are studied by the finite element method. Compared to the single-layer membrane structure, the double-layer membrane sensor has significant sensing properties such as a better wavelength sensitivity and a smaller full width at half maximum in the loss spectrum. In the refractive index range between 1.37 and 1.43, the maximum wavelength sensitivity and average wavelength sensitivity of the sensor are 19,900 nm/RIU and 7417 nm/RIU, respectively, and the resolution can be up to 5.03×10 . The proposed photonic crystal fiber optic sensor achieves high performance with a simpler sensing structure than previous photonic crystal fiber optic sensors, and eliminates the step of polishing, which will greatly reduce the difficulty of actual fabrication and the error due to uneven polishing. The results show that the photonic crystal fiber optic sensor with a double-layer membrane structure has excellent performance. Due to its high sensitivity and resolution, it has great potential for applications in environmental monitoring, biosensing and chemical sensing.

Download full-text PDF

Source
http://dx.doi.org/10.1364/JOSAA.531410DOI Listing

Publication Analysis

Top Keywords

photonic crystal
20
crystal fiber
20
double-layer membrane
16
membrane structure
16
wavelength sensitivity
12
fiber optic
12
sensor based
8
based double-layer
8
structure
8
surface plasmon
8

Similar Publications