Article Abstract

Rationale: Wildlife scientists are quantifying steroid hormones in a growing number of tissues and employing novel methods that must undergo validation before application. This study tested the accuracy and precision of liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods for use on blubber samples from short-finned pilot whales (Globicephala macrorhynchus). We expanded upon a method for corticosteroid quantification by adding analytes and optimizing internal standard (IS) application.

Methods: We optimized a method for the quantification of seven steroid hormones using LC-MS/MS with a C18 column. We assessed the accuracy and precision of this updated C18 method and an existing biphenyl method for use with pilot whale blubber by conducting a spike recovery experiment and calculating percent recovery and relative standard deviation (RSD) for each analyte. To explore the potential for running this method with fewer matched ISs, we compared the performance of multiple ISs for each analyte.

Results: All 11 adrenal and gonadal analytes showed good accuracy and precision in the spike recovery experiment, with recoveries between 82% and 110% and recovery RSDs below 10%. The C18 method detected all analytes at endogenous concentrations, except aldosterone. Although endogenous DHEA was detected, variability was high. IS comparisons showed 10 of 11 analytes could be calculated with comparable accuracy and precision using an IS substitute, but some substitutions significantly altered the analyte concentrations calculated.

Discussion: The C18 method was not sensitive enough for endogenous aldosterone detection. DHEA, which has not been previously quantified in blubber, was detected in all samples, but with high variability at lower concentrations. The methods in this study provide reliable detection and quantification of the other nine hormones tested and can be used for assessments of adrenal and gonadal steroid hormones from whales. Laboratories can reduce costs through IS substitution but should consider how these substitutions affect results.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.9965DOI Listing

Publication Analysis

Top Keywords

accuracy precision
16
steroid hormones
12
c18 method
12
short-finned pilot
8
pilot whale
8
whale blubber
8
liquid chromatography-tandem
8
chromatography-tandem mass
8
mass spectrometry
8
spectrometry lc-ms/ms
8

Similar Publications

Wearable bioelectronics for skin cancer management.

Biomaterials

August 2025

Department of Bioengineering, University of California, Los Angeles, Los Angeles, CA, 90095, USA. Electronic address:

Wearable bioelectronics have transformed modern biomedical applications by enabling seamless integration with biological tissues, providing continuous, comprehensive, and personalized healthcare. Skin cancer, particularly melanoma, poses a significant clinical challenge due to its high metastatic potential and associated mortality. Traditional diagnostic approaches face limitations in accuracy, accessibility, and reproducibility, while existing treatments are often constrained by systemic toxicity and therapeutic resistance.

View Article and Find Full Text PDF

ANASFV: a workflow for African swine fever virus whole-genome analysis.

Microb Genom

September 2025

Department of Infectious Diseases and Public Health, Jockey Club College of Veterinary Medicine and Life Sciences, City University of Hong Kong, Hong Kong, PR China.

African swine fever virus (ASFV) is highly transmissible and can cause up to 100% mortality in pigs. The virus has spread across most regions of Asia and Europe, resulting in the deaths of millions of pigs. A deep understanding of the genetic diversity and evolutionary dynamics of ASFV is necessary to effectively manage outbreaks.

View Article and Find Full Text PDF

The widespread dissemination of fake news presents a critical challenge to the integrity of digital information and erodes public trust. This urgent problem necessitates the development of sophisticated and reliable automated detection mechanisms. This study addresses this gap by proposing a robust fake news detection framework centred on a transformer-based architecture.

View Article and Find Full Text PDF

MicroRNAs (miRNAs) are critical regulators of gene expression in cancer biology, yet their spatial dynamics within tumor microenvironments (TMEs) remain underexplored due to technical limitations in current spatial transcriptomics (ST) technologies. To address this gap, we present STmiR, a novel XGBoost-based framework for spatially resolved miRNA activity prediction. STmiR integrates bulk RNA-seq data (TCGA and CCLE) with spatial transcriptomics profiles to model nonlinear miRNA-mRNA interactions, achieving high predictive accuracy (Spearman's ρ > 0.

View Article and Find Full Text PDF

Background: Metabolic syndrome (MetS) and sarcopenia are major global public health problems, and their coexistence significantly increases the risk of death. In recent years, this trend has become increasingly prominent in younger populations, posing a major public health challenge. Numerous studies have regarded reduced muscle mass as a reliable indicator for identifying pre-sarcopenia.

View Article and Find Full Text PDF